Isoplanatic patch of the human eye for arbitrary wavelengths.

Authors :
Han, Guoqing
Cao, Zhaoliang
Mu, Quanquan
Wang, Yukun
Li, Dayu
Wang, Shaoxin
Xu, Zihao
Wu, Daosheng
Hu, Lifa
Xuan, Li
Source :
Optics Communications. Mar2018, Vol. 410, p811-816. 6p.
Publication Year :
2018

Abstract

The isoplanatic patch of the human eye is a key parameter for the adaptive optics system (AOS) designed for retinal imaging. The field of view (FOV) usually sets to the same size as the isoplanatic patch to obtain high resolution images. However, it has only been measured at a specific wavelength. Here we investigate the wavelength dependence of this important parameter. An optical setup is initially designed and established in a laboratory to measure the isoplanatic patch at various wavelengths (655 nm, 730 nm and 808 nm). We established the Navarro wide-angle eye model in Zemax software to further validate our results, which suggested high consistency between the two. The isoplanatic patch as a function of wavelength was obtained within the range of visible to near-infrared, which can be expressed as: θ =0.0028 λ − 0 . 74 . This work is beneficial for the AOS design for retinal imaging. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00304018
Volume :
410
Database :
Academic Search Index
Journal :
Optics Communications
Publication Type :
Academic Journal
Accession number :
126828860
Full Text :
https://doi.org/10.1016/j.optcom.2017.11.055