Back to Search Start Over

A comparative study of mutation screening of sarcomeric genes (MYBPC3, MYH7, TNNT2) using single gene approach versus targeted gene panel next generation sequencing in a cohort of HCM patients in Egypt.

Authors :
Kassem, Heba Sh.
Walsh, Roddy
Barton, Paul J.
Abdelghany, Besra S.
Azer, Remon S.
Buchan, Rachel
John, Shibu
Elguindy, Ahmed
Moharem-ElGamal, Sarah
Badran, Hala M.
Shehata, Hoda
Cook, Stuart A.
Yacoub, Magdi H.
Source :
Egyptian Journal of Medical Human Genetics. 2017, Vol. 18 Issue 4, p381-387. 7p.
Publication Year :
2017

Abstract

Background: NGS enables simultaneous sequencing of large numbers of associated genes in genetic heterogeneous disorders, in a more rapid and cost-effective manner than traditional technologies. However there have been limited direct comparisons between NGS and more established technologies to assess the sensitivity and false negative rates of this new approach. The scope of the present manuscript is to compare variants detected in MYBPC3, MYH7 and TNNT2 genes using the stepwise dHPLC/ Sanger versus targeted NGS. Methods: In this study, we have analysed a group of 150 samples of patients from the Bibliotheca Alexandrina-Aswan Heart Centre National HCM program. The genetic testing was simultaneously undertaken by high throughput denaturing high-performance liquid chromatography (dHPLC) followed by Sanger based sequencing and targeted next generation deep sequencing using panel of inherited cardiac genes (ICC). The panel included over 100 genes including the 3 sarcomeric genes. Analysis of the sequencing data of the 3 genes was undertaken in a double blinded strategy. Results: NGS analysis detected all pathogenic and likely pathogenic variants identified by dHPLC (50 in total, some samples had double hits). There was a 0% false negative rate for NGS based analysis. Nineteen variants were missed by dHPLC and detected by NGS, thus increasing the diagnostic yield in this co- analysed cohort from 22.0% (33/150) to 31.3% (47/150). Of interest to note that the mutation spectrum in this Egyptian HCM population revealed a high rate of homozygosity in MYBPC3 and MYH7 genes in comparison to other population studies (6/150, 4%). None of the homozygous samples were detected by dHPLC analysis. Conclusion: NGS provides a useful and rapid tool to allow panoramic screening of several genes simultaneously with a high sensitivity rate amongst genes of known etiologic role allowing high throughput analysis of HCM patients and relevant control series in a less characterised population. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
11108630
Volume :
18
Issue :
4
Database :
Academic Search Index
Journal :
Egyptian Journal of Medical Human Genetics
Publication Type :
Academic Journal
Accession number :
125852676
Full Text :
https://doi.org/10.1016/j.ejmhg.2017.05.002