Back to Search
Start Over
Combined effects of fretting and pollutant particles on the contact resistance of the electrical connectors.
- Source :
-
Progress in Natural Science . Jun2017, Vol. 27 Issue 3, p385-390. 6p. - Publication Year :
- 2017
-
Abstract
- Usually, when electrical connectors operate in vibration environments, fretting will be produced at the contact interfaces. In addition, serious environmental pollution particles will affect contact resistance of the connectors. The fretting will worsen the reliability of connectors with the pollutant particles. The combined effects of fretting and quartz particles on the contact resistance of the gold plating connectors are studied with a fretting test system. The results show that the frequencies have obvious effect on the contact resistance. The higher the frequency, the higher the contact resistance is. The quartz particles cause serious wear of gold plating, which make the nickel and copper layer exposed quickly to increase the contact resistance. Especially in high humidity environments, water supply certain adhesion function and make quartz particles easy to insert or cover the contact surfaces, and even cause opening resistance. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10020071
- Volume :
- 27
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- Progress in Natural Science
- Publication Type :
- Academic Journal
- Accession number :
- 124141764
- Full Text :
- https://doi.org/10.1016/j.pnsc.2017.04.018