Back to Search
Start Over
Kristalin Lens Esnekliğinde Yaşa Bağlı Değişim: Siklopleji ile Lens Kalınlığındaki Değişimin Swept Source Optik Biyometri ile Değerlendirilmesi.
- Source :
-
Journal of Glaucoma-Cataract / Glokom-Katarakt . jun2017, Vol. 12 Issue 2, p119-122. 4p. 1 Chart. - Publication Year :
- 2017
-
Abstract
- Purpose: Elasticity of crystalline lens is ability to deformability during near-vision and resting. The change in cristalline lens thickness (LT) with cycloplegia is a result of lens elasticity. In our study the change in LT was quantified with swept source optical biometry, the effect of aging was evaluated, and the subject was shortly reviewed. Material and Method: All 36 eyes of 36 patients aged between 20 and 39 (group 1) and 40 and 60 (group 2) years were included in the study. The measurements were taken in roomlight before and after dilation with using swept source optical biometry. The difference of LT due to dilation were compared between the groups. Results: The mean change in LT after dilation was 0.08 ± 0.02 mm in group 1, 0.04 ± 0.01mm in group 2 and statistically significant (p < 0.001, p = 0.012). The change in LT between group 1 and 2 was statistically significant (p = 0.015). Conclusion: The change in LT was maximum in young ages and decreases over time. The findings were compatible with the changes occurred in the lens with aging. [ABSTRACT FROM AUTHOR]
Details
- Language :
- Turkish
- ISSN :
- 13059173
- Volume :
- 12
- Issue :
- 2
- Database :
- Academic Search Index
- Journal :
- Journal of Glaucoma-Cataract / Glokom-Katarakt
- Publication Type :
- Academic Journal
- Accession number :
- 123962985