Back to Search Start Over

Drift-Compensated Low-Noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1.

Authors :
Heo, Myoung-Sun
Park, Sang Eon
Lee, Won-Kyu
Lee, Sang-Bum
Hong, Hyun-Gue
Kwon, Taeg Yong
Park, Chang Yong
Yu, Dai-Hyuk
Santarelli, Giorgio
Hilton, Ashby Paul
Luiten, Andre Nicholas
Hartnett, John Gideon
Source :
IEEE Transactions on Instrumentation & Measurement. Jun2017, Vol. 66 Issue 6, p1343-1348. 6p.
Publication Year :
2017

Abstract

In this paper, we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency comb locked to an ultrastable laser, is better than 5×10−15 at an averaging time of 1 s. We demonstrate that the short-term stability of the synthesizer is lower than the quantum projection noise limit of the Cs fountain clock, KRISS-F1(Cs) by measuring the short-term stability of the fountain with varying trapped atom number. The stability of the atomic fountain at 1 s averaging time reaches 2.5×10−14 at the highest atom number in the experiment when the synthesizer is used as an interrogation oscillator of the fountain. In order to compensate the frequency drift of the CSO, the output frequency of a waveform generator, in the synthesis chain, is ramped linearly. By doing this, the frequency stability of the synthesizer at an average time of one hour reaches a level of 10−16, which is measured with the fountain clock. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189456
Volume :
66
Issue :
6
Database :
Academic Search Index
Journal :
IEEE Transactions on Instrumentation & Measurement
Publication Type :
Academic Journal
Accession number :
123209545
Full Text :
https://doi.org/10.1109/TIM.2016.2620187