Back to Search Start Over

Atomic structure of granulin determined from native nanocrystalline granulovirus using an X-ray free-electron laser.

Authors :
Gati, Cornelius
Oberthuer, Dominik
Yefanov, Oleksandr
Bunker, Richard D.
Stellato, Francesco
Chiu, Elaine
Shin-Mei Yeh
Aquila, Andrew
Basu, Shibom
Bean, Richard
Beyerlein, Kenneth R.
Botha, Sabine
Boutet, Sébastien
DePonte, Daniel P.
Doak, R. Bruce
Fromme, Raimund
Galli, Lorenzo
Grotjohann, Ingo
James, Daniel R.
Kupitz, Christopher
Source :
Proceedings of the National Academy of Sciences of the United States of America. 2/28/2017, Vol. 114 Issue 9, p2247-2252. 6p. 2 Color Photographs, 1 Black and White Photograph, 1 Chart, 1 Graph.
Publication Year :
2017

Abstract

To understand how molecules function in biological systems, new methods are required to obtain atomic resolution structures from biological material under physiological conditions. Intense femtosecond-duration pulses from X-ray free-electron lasers (XFELs) can outrun most damage processes, vastly increasing the tolerable dose before the specimen is destroyed. This in turn allows structure determination from crystals much smaller and more radiation sensitive than previously considered possible, allowing data collection from room temperature structures and avoiding structural changes due to cooling. Regardless, high-resolution structures obtained from XFEL data mostly use crystals far larger than 1 μm3 in volume, whereas the X-ray beam is often attenuated to protect the detector from damage caused by intense Bragg spots. Here, we describe the 2 Å resolution structure of native nanocrystalline granulovirus occlusion bodies (OBs) that are less than 0.016 μm3 in volume using the full power of the Linac Coherent Light Source (LCLS) and a dose up to 1.3 GGy per crystal. The crystalline shell of granulovirus OBs consists, on average, of about 9,000 unit cells, representing the smallest protein crystals to yield a high-resolution structure by X-ray crystallography to date. The XFEL structure shows little to no evidence of radiation damage and is more complete than a model determined using synchrotron data from recombinantly produced, much larger, cryocooled granulovirus granulin microcrystals. Our measurements suggest that it should be possible, under ideal experimental conditions, to obtain data from protein crystals with only 100 unit cells in volume using currently available XFELs and suggest that single-molecule imaging of individual biomolecules could almost be within reach. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00278424
Volume :
114
Issue :
9
Database :
Academic Search Index
Journal :
Proceedings of the National Academy of Sciences of the United States of America
Publication Type :
Academic Journal
Accession number :
121512042
Full Text :
https://doi.org/10.1073/pnas.1609243114