Back to Search Start Over

Dynamic modelling and optimization of an LNG storage tank in a regasification terminal with semi-analytical solutions for N2-free LNG.

Authors :
Effendy, Surya
Khan, Mohd Shariq
Farooq, Shamsuzzaman
Karimi, Iftekhar A.
Source :
Computers & Chemical Engineering. Apr2017, Vol. 99, p40-50. 11p.
Publication Year :
2017

Abstract

A comprehensive dynamic model for an LNG storage tank in a typical regasification terminal, operating in holding mode, is presented. The model incorporates LNG recirculation for cooling the transfer lines for loading/unloading. It assumes a hypothetical thin vapour interface in equilibrium with the liquid to compute LNG evaporation, which allows the boil-off gas to be hotter than the tank LNG, as observed in practice. A numerical procedure based on the secant method is implemented in MATLAB for solving the governing ordinary differential equations. For the special case of N 2 -free LNG, a semi-analytical solution is proposed to solve the dynamic model for this relatively complex system and compute the amount of boil-off gas (BOG). The semi-analytical solution is subsequently used to optimize the LNG storage tank and recirculation loop designs. [ABSTRACT FROM AUTHOR]