Back to Search Start Over

Daily precipitation estimation through different microwave sensors: Verification study over Italy.

Authors :
Ciabatta, Luca
Marra, Anna Cinzia
Panegrossi, Giulia
Casella, Daniele
SanĂ², Paolo
Dietrich, Stefano
Massari, Christian
Brocca, Luca
Source :
Journal of Hydrology. Feb2017, Vol. 545, p436-450. 15p.
Publication Year :
2017

Abstract

The accurate estimation of rainfall from remote sensing is of paramount importance for many applications as, for instance, the mitigation of natural hazards like floods, droughts, and landslides. Traditionally, microwave observations in the frequency between 10 and 183 GHz are used for estimating rainfall based on the direct interaction of radiation with the hydrometeors within precipitating clouds in a so-called top-down approach. Recently, a bottom-up approach was proposed that uses satellite soil moisture products derived from microwave observations (<10 GHz) for the estimation of accumulated rainfall amounts. The integration of the bottom-up and top-down approaches has large potential for providing high accurate rainfall estimates exploiting their different and complementary nature. In this study, we perform a long-term (3 years) assessment of different satellite rainfall products exploiting the full range of microwave frequencies over Italy. Specifically, the integration of two top-down algorithms (CDRD, Cloud Dynamics and Radiation Database, and PNPR, Passive microwave Neural network Precipitation Retrieval) for estimating rainfall from conically and cross-track scanning radiometers, and one bottom-up algorithm (SM2RAIN) applied to the Advanced SCATterometer soil moisture product is carried out. The performances of the products, individually and merged together, are assessed at daily time scale. The integration of top-down and bottom-up approaches provides the highest performance both in terms of continuous and categorical scores (i.e., median correlation coefficient and root mean square error values equal to 0.71 and 6.62 mm, respectively). In such a combination, the limitations of the two approaches are compensated allowing a better estimation of ground accumulated rainfall through SM2RAIN while, overcoming the limitations of rainfall estimation for intense events during wet conditions through CDRD-PNPR product. The accuracy and the reliability of the merged product open new possibilities for their testing in hydrological applications, such as the monitoring and prediction of floods and droughts over large areas, including regions where ground-based measurements are sparse or not available. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00221694
Volume :
545
Database :
Academic Search Index
Journal :
Journal of Hydrology
Publication Type :
Academic Journal
Accession number :
121067272
Full Text :