Fire Resistance of Unprotected Ultra Shallow Floor Beams (USFB): A Numerical Investigation.
- Source :
-
Fire Technology . Mar2017, Vol. 53 Issue 2, p609-627. 19p. - Publication Year :
- 2017
-
Abstract
- This paper presents the fire resistance behaviour of partially encased in concrete ultra shallow floor beams (USFB) using numerical analysis method based on material specifications of the EN1994-1-2. Investigating the behaviour of USFBs under elevated temperatures is crucial in determining their fire resistance and evaluating their overall performance in contemporary construction. Even though the manufacturing company provides fire resistances for USFBs based on EC4-1-2 procedures, their response to elevated temperature effects remains up to date neither well documented nor clearly understood. The analyses involved two different beams of span 5 m and 8 m respectively, as specified by the manufacturer. Analysis results showed that such beams, when unprotected, experience severe temperature gradients if exposed to fire, as the lower flange still remains unprotected in contrast to the concrete encased part of the cross-section. As it was anticipated, the moment capacity governs the fire resistance of the beams and the load factor highly effects the elevated temperature behaviour. In addition, the loss of the lower flange, which develops high temperatures, is not compensated by the web and consequently the moment capacity ultimately depends on the temperature of the lower flange. Results also suggest that simulated beams sustained the applied load for approximately 40 min of exposure to the standard fire. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00152684
- Volume :
- 53
- Issue :
- 2
- Database :
- Academic Search Index
- Journal :
- Fire Technology
- Publication Type :
- Academic Journal
- Accession number :
- 121001858
- Full Text :
- https://doi.org/10.1007/s10694-016-0583-5