Back to Search
Start Over
Automatic analysis of electro-encephalogram sleep spindle frequency throughout the night.
- Source :
-
Medical & Biological Engineering & Computing . Nov2003, Vol. 41 Issue 6, p727-732. 6p. 1 Diagram, 1 Chart, 4 Graphs. - Publication Year :
- 2003
-
Abstract
- A fully automatic method to analyse electro-encephalogram (EEG) sleep spindle frequency evolution during the night was developed and tested. Twenty all-night recordings were studied from ten healthy control subjects and ten sleep apnoea patients. A total of 22868 spindles were detected. The overall mean spindle frequency was significantly higher in the control subjects than in the apnoea patients (12.5Hz against 11.7Hz, respectively; p<0.004). The proposed method further identified the sleep depth cycles, and the mean spindle frequency was automatically determined inside each sleep depth cycle. In control subjects, the mean spindle frequency increased from 12.0Hz in the first sleep depth cycle to 12.6Hz in the fifth cycle. No such increase was observed in the sleep apnoea patients. This difference in the spindle frequency evolution was statistically significant (p< 0.004). The advantage of the method is that no EEG amplitude thresholds are needed. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 01400118
- Volume :
- 41
- Issue :
- 6
- Database :
- Academic Search Index
- Journal :
- Medical & Biological Engineering & Computing
- Publication Type :
- Academic Journal
- Accession number :
- 11900323
- Full Text :
- https://doi.org/10.1007/BF02349981