Back to Search Start Over

Long-Term Follow-Up of Isolated Epicardial Left Ventricular Lead Implant Using a Minithoracotomy Approach for Cardiac Resynchronization Therapy.

Authors :
McALOON, CHRISTOPHER J.
ANDERSON, BENJAMIN M.
DIMITRI, WADIH
PANTING, JONATHAN
YUSUF, SHAMIL
BHUDIA, SUNIL K.
OSMAN, FAIZEL
Source :
Pacing & Clinical Electrophysiology. Oct2016, Vol. 39 Issue 10, p1052-1060. 9p.
Publication Year :
2016

Abstract

Background Transvenous left ventricular (LV) lead placement for cardiac resynchronization therapy is unsuccessful in 5-10% of reported cases. These patients may benefit from isolated surgical placement of an epicardial LV lead via minithoracotomy approach. Aim To evaluate the success of this approach at long-term follow-up. Methods Retrospective evaluation of all consecutive patients undergoing isolated epicardial LV lead placement after failed transvenous attempt over a 6-year period. Data collected on baseline parameters, procedural details, and outcome at follow-up (hospital stay, complications, mortality, and clinical response). Results Forty-two patients underwent epicardial lead implant. Five died within 1 year (11.9%): two (4.8%) died within 30-days post op (one from intraoperative hemorrhage, the other from multiple organ failure); 39 (95.1%) were admitted to the high dependency unit and transferred to the ward <24 hours. Median hospital stay was 3.4 ± 1.9 days. The overall complication rate was 17.5% (n = 7): 15.0% (n = 6) short term and 2.5% (n = 1) long term; these included three (7.5%) LV noncapture events all treated with reprogramming. There were two (5.0%) wound infections requiring oral antibiotics and two (5.0%) device infections requiring intravenous antibiotics (one had device resiting, the other developed septic shock requiring intensive care admission). Assessment of clinical response was possible in 34 (81.0%) at follow-up: 21 (61.8%) were responders and 13 (28.2%) nonresponders with no significant differences between these groups; no clinical predictors of response were identified. Conclusion Isolated epicardial LV lead implant using minithoracotomy is relatively safe and effective at successful LV pacing. Response rate and postoperative recovery at long-term follow-up are reasonable in these high-risk patients. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01478389
Volume :
39
Issue :
10
Database :
Academic Search Index
Journal :
Pacing & Clinical Electrophysiology
Publication Type :
Academic Journal
Accession number :
118669183
Full Text :
https://doi.org/10.1111/pace.12932