Layered shielding design for an active neutron interrogation system.
- Source :
-
Radiation Physics & Chemistry . Aug2016, Vol. 125, p69-74. 6p. - Publication Year :
- 2016
-
Abstract
- The use of source and detector shields in active neutron interrogation can improve detector signal. In simulations, a shielded detector with a source rotated π/3 rad relative to the opening decreased neutron flux roughly three orders of magnitude. Several realistic source and detector shield configurations were simulated. A layered design reduced neutron and secondary photon flux in the detector by approximately one order of magnitude for a deuterium–tritium source. The shield arrangement can be adapted for a portable, modular design. [ABSTRACT FROM AUTHOR]