The SHELS velocity filter originated upon reconstruction of the VASSILISSA electrostatic separator used for investigations of heavy nuclei produced in complete fusion reactions. The goals of this modernization were to increase the transmission of products of asymmetric reactions and to extend the region of reactions to be investigated up to symmetric combinations. The first tests of the set-up were performed with the beams of accelerated 22 Ne, 40 Ar, 48 Ca, and 50 Ti ions. [ABSTRACT FROM AUTHOR]