Back to Search
Start Over
Performance of simultaneous high temporal resolution quantitative perfusion imaging of bladder tumors and conventional multi-phase urography using a novel free-breathing continuously acquired radial compressed-sensing MRI sequence.
- Source :
-
Magnetic Resonance Imaging (0730725X) . Jun2016, Vol. 34 Issue 5, p694-698. 5p. - Publication Year :
- 2016
-
Abstract
- Purpose To investigate the feasibility of high temporal resolution quantitative perfusion imaging of bladder tumors performed simultaneously with conventional multi-phase MR urography (MRU) using a novel free-breathing continuously acquired radial MRI sequence with compressed-sensing reconstruction. Methods 22 patients with bladder lesions underwent MRU using GRASP (Golden-angle RAdial Sparse Parallel) acquisition. Multi-phase contrast-enhanced abdominopelvic GRASP was performed during free-breathing (1.4 × 1.4 × 3.0 mm 3 voxel size; 3:44 min acquisition). Two dynamic datasets were retrospectively reconstructed by combining different numbers of sequentially acquired spokes into each dynamic frame: 110 spokes per frame for 25-s temporal resolution (serving as conventional MRU for clinical interpretation) and 8 spokes per frame for 1.7-s resolution. Using 1.7-s resolution images, ROIs were placed within bladder lesions and normal bladder wall, a femoral artery arterial input function was generated, and the Generalized Kinetic Model was applied. Results Biopsy/cystectomy demonstrated 16 bladder tumors (13 stage ≥ T2, 3 stage ≤ T1) and 6 benign lesions. All lesions were well visualized using 25-s clinical multi-phase images. Using 1.7-s resolution images, K trans was significantly higher in tumors (0.38 ± 0.24) than normal bladder (0.12 ± 0.02 = 8, p < 0.001) or benign lesions (0.15 ± 0.04, p = 0.033). Ratio between K trans of lesions and normal bladder was nearly double for tumors than benign lesions (4.3 ± 3.4 vs. 2.2 ± 1.6), and K trans was nearly double in stage ≥ T2 than stage ≤ T1 tumors (0.44 ± 0.24 vs. 0.24 ± 0.24), although these did not approach significance (p = 0.180–0.209), possibly related to small sample size. Conclusion GRASP allows simultaneous quantitative high temporal resolution perfusion of bladder lesions during clinical MRU examinations using only one contrast injection and without additional scan time. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0730725X
- Volume :
- 34
- Issue :
- 5
- Database :
- Academic Search Index
- Journal :
- Magnetic Resonance Imaging (0730725X)
- Publication Type :
- Academic Journal
- Accession number :
- 115069371
- Full Text :
- https://doi.org/10.1016/j.mri.2015.12.033