Back to Search Start Over

Fluctuation of Microcystins in Water Plant.

Authors :
Jia, R. B.
Zhang, X. H.
Zhang, W. H.
Zhang, G. M.
Wang, Z. S.
Source :
Journal of Environmental Science & Health. Part A. Toxic/Hazardous Substances & Environmental Engineering. Dec2003, Vol. 38 Issue 12, p2867-2875. 9p.
Publication Year :
2003

Abstract

This study was undertaken to investigate the distribution and variation of microcystins (MC) from a water resource to a water plant in China including long distance transportation, ClO2 preoxidation, coagulation/precipitation, filtration, and disinfection. Advanced treatment methods including ozonation and granular activated carbon (GAC) adsorption were tested to remove microcystins from drinking water. The results indicated that, when containing high level of algae in raw water, preoxidation at 2 mg/L of ClO2 was not enough to stop algae growth in long distance transportation. In the water plant studied, both coagulation and filtration caused significant increase instead of removal of microcystins in drinking water. Chlorine disinfection removed part of microcystins. However, both ozonation and GAC adsorption were able to remove microcystins completely, thereby improving the quality of drinking water in terms of microcystins. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10934529
Volume :
38
Issue :
12
Database :
Academic Search Index
Journal :
Journal of Environmental Science & Health. Part A. Toxic/Hazardous Substances & Environmental Engineering
Publication Type :
Academic Journal
Accession number :
11463479
Full Text :
https://doi.org/10.1081/ESE-120025837