Back to Search Start Over

Assessment of corneal biomechanical parameters in myopes and emmetropes using the Corvis ST.

Authors :
Lee, Rachel
Chang, Robert T
Wong, Ian Y H
Lai, Jimmy S M
Lee, Jacky W Y
Singh, Kuldev
Source :
Clinical & Experimental Optometry. Mar2016, Vol. 99 Issue 2, p157-162. 6p.
Publication Year :
2016

Abstract

<bold>Background: </bold>Prior studies have demonstrated conflicting results regarding the relationship between corneal biomechanical properties and refractive error. Thus, the purpose of this study was to compare the corneal biomechanical parameters of myopes and emmetropes.<bold>Methods: </bold>Ninety-four subjects with varying degrees of myopia (aged 29 to 74 years, spherical equivalent [SE] -0.5 to -17.5 D) and 25 emmetropes (aged 19 to 75 years, SE: -0.5 to +0.5 D) presenting at the Queen Mary Hospital, Hong Kong were recruited sequentially for this prospective study. All patients were phakic with no history of coexisting ocular disease. The corneal biomechanical parameters of the right eye of each subject were analysed using the Corvis ST non-contact tonometer. Intraocular pressure (IOP) was measured using both the Corvis ST and the Topcon Non-Contact Tonometer CT-80. Refractive error was measured by non-cycloplegic subjective and objective refractometry.<bold>Results: </bold>High myopes (SE greater than -6.00 D) demonstrated greater mean outward applanation velocities (p < 0.001) and peak distance measurements (p = 0.009) compared to both low to moderate myopes (SE -0.50 to -6.00 D) and emmetropes. Both outward applanation velocity and peak distance were moderately correlated with refractive error (p ≤ 0.001), strongly correlated with IOP and weakly correlated with central corneal thickness. There were no statistically significant differences in age, IOP or central corneal thickness among emmetropes, low to moderate myopes or high myopes.<bold>Conclusion: </bold>Within this study of Chinese subjects, high myopes demonstrate greater corneal mean outward applanation velocity on Corvis ST testing, than emmetropes. In particular, those with high myopia (SE greater than -6.00 D) show a distinct corneal biomechanical profile relative to those with either emmetropia or low to moderate myopia using the Corvis ST. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08164622
Volume :
99
Issue :
2
Database :
Academic Search Index
Journal :
Clinical & Experimental Optometry
Publication Type :
Academic Journal
Accession number :
113970362
Full Text :
https://doi.org/10.1111/cxo.12341