Back to Search
Start Over
Significance of the ADC ratio in the differential diagnosis of breast lesions.
- Source :
-
Acta Radiologica . Apr2016, Vol. 57 Issue 4, p422-429. 8p. - Publication Year :
- 2016
-
Abstract
- <bold>Background: </bold>Magnetic resonance imaging (MRI) has high sensitivity but low specificity for breast cancer, and consequently, new techniques to improve the specificity of breast MRI in diagnosing breast cancer are under development.<bold>Purpose: </bold>To assess the ability of the apparent diffusion coefficient (ADC) compared with the ADC ratio (ADCr) to differentially diagnose benign compared with malignant breast lesions.<bold>Material and Methods: </bold>Forty-eight women with breast lesions (average age, 45 years) underwent MRI scanning including T1-weighted dynamic contrast-enhanced (DCE) scanning and diffusion-weighted imaging (DWI). The average ADC and ADCr values for both lesions and pectoralis major muscles (ADCrmuscle and ADCrmuscle) were measured in patients with malignant (n = 25) and benign (n = 23) breast lesions. The ADCr of the contralateral breast (ADCr contralateral) was also evaluated. All histology was confirmed by pathological analysis of biopsied tissue. ADC and ADCr values were analyzed using receiver-operating characteristic (ROC) curves.<bold>Results: </bold>For benign lesions compared with malignant lesions, lesion-side ADC was 1.45 vs. 1.05, respectively (P < 0.001), normal-side ADC was 1.82 vs.1.64 (P = 0.002), ADCrmuscle was 1.35 vs. 0.9 (P < 0.001), and ADCrcontralateral was 0.79 vs. 0.64 (P = 0.001). ADCrmuscle showed higher sensitivity (82.61%) and specificity (96.00%) than ADCrcontralateral (60.87% and 92.00%, respectively) and ADC (69.57% and 96.00%) for discriminating malignant from benign lesions. The AUC using ADCrmuscle had higher discriminatory power (0.92, P < 0.001) for malignant versus benign breast lesions compared with either ADC (0.82, P < 0.001) or ADCrcontralateral (0.78, P = 0.001).<bold>Conclusion: </bold>The ADCrmuscle value showed higher sensitivity and specificity and improved diagnostic accuracy compared with either ADC or ADCrcontralateral in differentiating benign from malignant breast lesions. [ABSTRACT FROM AUTHOR]
- Subjects :
- *BREAST cancer diagnosis
*MAGNETIC resonance mammography
*DIFFUSION coefficients
*BREAST biopsy
*PRECANCEROUS conditions
*BREAST
*BREAST tumors
*DIFFERENTIAL diagnosis
*DIAGNOSTIC imaging
*MAGNETIC resonance imaging
*CONTRAST media
*RETROSPECTIVE studies
*RECEIVER operating characteristic curves
RESEARCH evaluation
Subjects
Details
- Language :
- English
- ISSN :
- 02841851
- Volume :
- 57
- Issue :
- 4
- Database :
- Academic Search Index
- Journal :
- Acta Radiologica
- Publication Type :
- Academic Journal
- Accession number :
- 113645450
- Full Text :
- https://doi.org/10.1177/0284185115590286