Chemical Exchange Saturation Transfer (CEST) MR Technique for Liver Imaging at 3.0 Tesla: an Evaluation of Different Offset Number and an After-Meal and Over-Night-Fast Comparison.

Authors :
Deng, Min
Chen, Shu-Zhong
Yuan, Jing
Chan, Queenie
Zhou, Jinyuan
Wáng, Yì-Xiáng
Wáng, Yì-Xiáng J
Source :
Molecular Imaging & Biology. Apr2016, Vol. 18 Issue 2, p274-282. 9p.
Publication Year :
2016

Abstract

<bold>Purpose: </bold>This study seeks to explore whether chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) can detect liver composition changes between after-meal and over-night-fast statuses.<bold>Procedures: </bold>Fifteen healthy volunteers were scanned on a 3.0-T human MRI scanner in the evening 1.5-2 h after dinner and in the morning after over-night (12-h) fasting. Among them, seven volunteers were scanned twice to assess the scan-rescan reproducibility. Images were acquired at offsets (n = 41, increment = 0.25 ppm) from -5 to 5 ppm using a turbo spin echo (TSE) sequence with a continuous rectangular saturation pulse. Amide proton transfer-weighted (APTw) and GlycoCEST signals were quantified with the asymmetric magnetization transfer ratio (MTRasym) at 3.5 ppm and the total MTRasym integrated from 0.5 to 1.5 ppm from the corrected Z-spectrum, respectively. To explore scan time reduction, CEST images were reconstructed using 31 offsets (with 20% time reduction) and 21 offsets (with 40% time reduction), respectively.<bold>Results: </bold>For reproducibility, GlycoCEST measurements in 41 offsets showed the smallest scan-rescan mean measurements variability, indicated by the lowest mean difference of -0.049% (95% limits of agreement, -0.209 to 0.111%); for APTw, the smallest mean difference was found to be 0.112% (95% limits of agreement, -0.698 to 0.921%) in 41 offsets. Compared with after-meal, both GlycoCEST measurement and APTw measurement under different offset number decreased after 12-h fasting. However, as the offsets number decreased (41 offsets vs. 31 offsets vs. 21 offsets), GlycoCEST map and APTw map became more heterogeneous and noisier.<bold>Conclusion: </bold>Our results show that CEST liver imaging at 3.0 T has high sensitivity for fasting. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15361632
Volume :
18
Issue :
2
Database :
Academic Search Index
Journal :
Molecular Imaging & Biology
Publication Type :
Academic Journal
Accession number :
113577017
Full Text :
https://doi.org/10.1007/s11307-015-0887-8