Locating Multiple Soft Faults in Wire Networks Using an Alternative DORT Implementation.

Authors :
Kafal, Moussa
Cozza, Andrea
Pichon, Lionel
Source :
IEEE Transactions on Instrumentation & Measurement. Feb2016, Vol. 65 Issue 2, p399-406. 8p.
Publication Year :
2016

Abstract

Decomposition of the time reversal operator (DORT) was recently applied to the problem of detection and location of soft faults in wire networks and proved effectual when dealing with a single fault, even in the case of complex network configurations. In this paper, the case of location of multiple faults is addressed, first proving that the standard DORT formulation does not allow one to take a clear decision about the individual position of each fault. An alternative version of the DORT based on an updating procedure is presented and demonstrated to enable accurate and selective location of multiple soft faults. The proposed procedure is also shown to allow estimating the reflection coefficient of each fault, thus giving access to their severity. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189456
Volume :
65
Issue :
2
Database :
Academic Search Index
Journal :
IEEE Transactions on Instrumentation & Measurement
Publication Type :
Academic Journal
Accession number :
112077505
Full Text :
https://doi.org/10.1109/TIM.2015.2498559