Back to Search Start Over

Performance of hydraulic turbocharger integrated with hydraulic energy management in SWRO desalination plants.

Authors :
El-Sayed, Tamer A.
Abdel Fatah, Amr A.
Source :
Desalination. Feb2016, Vol. 379, p85-92. 8p.
Publication Year :
2016

Abstract

Hydraulic turbocharger is a common energy recovery device used in reverse osmosis water desalination plants to recover the stored energy in brine. Also, it can be used to control the pressure variation due to the change of plant operating conditions. The aim of the current work is to apply the computational fluid dynamics (CFD) to investigate the balance between the hydraulic turbocharger turbine and pump sections. The effect of changing the rotor speed and the effect of auxiliary line size and valve opening on the performance of the hydraulic turbocharger are also investigated. In addition, the effect of these changes on the plant specific energy consumption (SEC) is discussed. The results of the current work present the variation of the hydraulic turbocharger performance with the rotor speed. It also shows that increasing the turbine auxiliary line diameter reduces the turbine inlet pressure. The CFD results show that opening the auxiliary line reduces the turbine inlet pressure which reduces the rotor speed and the pump boosting pressure. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00119164
Volume :
379
Database :
Academic Search Index
Journal :
Desalination
Publication Type :
Academic Journal
Accession number :
111292282
Full Text :