Back to Search Start Over

Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals.

Authors :
Keisuke Nakamura
Masayoshi Ohira
Yoshiharu Yokokawa
Yuya Nagasawa
Source :
Journal of Sports Science & Medicine. Dec2015, Vol. 14 Issue 4, p708-715. 8p.
Publication Year :
2015

Abstract

Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 ± 1.9 mL⋅min-⋅kg-) and the CE test (18.4 ± 1.8 mL⋅min-⋅kg-) were significantly higher than those during the ISTS without arm support (16.6 ± 1.8 mL-min"1-kg"1; p < 0.05). The AT-HR values during the ISTS with arm support (126 ± 10 bpm) and the CE test (126 ±13 bpm) were significantly higher than those during the ISTS without arm support (119 ± 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13032968
Volume :
14
Issue :
4
Database :
Academic Search Index
Journal :
Journal of Sports Science & Medicine
Publication Type :
Academic Journal
Accession number :
111246113