Load limit of a UASB fed septic tank-treated domestic wastewater.
- Source :
-
Water Science & Technology . 2015, Vol. 72 Issue 8, p1455-1461. 7p. - Publication Year :
- 2015
-
Abstract
- Performance of a 250 L pilot-scale up-flow anaerobic sludge blanket (UASB) reactor, operated at ambient temperatures, fed septic tank effluents intermittently, was monitored for hydraulic retention time (HRT) from 18 h to 4 h. The total suspended solids (TSS), total chemical oxygen demand (CODT), dissolved chemical oxygen demand (CODdis) and suspended chemical oxygen demand (CODss) removal efficiencies ranged from 20 to 63%, 15 to 56%, 8 to 35% and 22 to 72%, respectively, for the HRT range tested. Above 60% TSS and 47% CODT removal were obtained in the combined septic tank and UASB process. The process established stable UASB treatment at HRT ≥ 6 h, indicating a hydraulic load design limit. The tested septic tank-UASB combined system can be a low-cost and effective on-site sanitation solution. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02731223
- Volume :
- 72
- Issue :
- 8
- Database :
- Academic Search Index
- Journal :
- Water Science & Technology
- Publication Type :
- Academic Journal
- Accession number :
- 110618383
- Full Text :
- https://doi.org/10.2166/wst.2015.358