Back to Search Start Over

Fuzzy Logic Based Rotor Health Index of Induction Motor.

Authors :
Misra, Rajul
Pahuja, G. L.
Source :
International Journal of Emerging Electric Power Systems. Oct2015, Vol. 16 Issue 5, p443-449. 7p. 2 Color Photographs, 1 Black and White Photograph, 5 Charts, 3 Graphs.
Publication Year :
2015

Abstract

This paper presents an experimental study on detection and diagnosis of broken rotor bars in Squirrel Cage Induction Motor (SQIM). The proposed scheme is based on Motor Current Signature Analysis (MCSA) which uses amplitude difference of supply frequency to upper and lower side bands. Initially traditional MCSA has been used for rotor fault detection. It provides rotor health index on full load conditions. However in real practice if a fault occurs motor can not run at full load. To overcome the issue of reduced load condition a Fuzzy Logic based MCSA has been designed, implemented, tested and compared with traditional MCSA. A simulation result shows that proposed scheme is not only capable of detecting the severity of rotor fault but also provides remarkable performance at reduced load conditions. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1553779X
Volume :
16
Issue :
5
Database :
Academic Search Index
Journal :
International Journal of Emerging Electric Power Systems
Publication Type :
Academic Journal
Accession number :
110258794
Full Text :
https://doi.org/10.1515/ijeeps-2015-0032