Analysis of arc interference and welding stability in twin wire GMA welding.

Authors :
Ye, Dingjian
Hua, Xueming
Zhang, Jing
Wu, Yixiong
Bai, Yan
Lv, Yaping
Source :
International Journal of Advanced Manufacturing Technology. Oct2015, Vol. 81 Issue 1-4, p627-633. 7p. 6 Diagrams, 4 Charts, 2 Graphs.
Publication Year :
2015

Abstract

In order to better understand the arc interference behavior and welding stability in twin wire GMA welding, the synchronous acquisition system has been established to acquire instantaneous information of electric signals, arc profile, and droplet transfer including dynamic arc length variation. The results showed that after Trailing arc (T-arc) was added to the Leading arc (L-arc) in a stable welding process, the current of L-arc decreased and the voltage kept constant. The stable globular transfer of L-arc was destroyed and deflected, turned into spray transfer due to the effect of T-arc. Compared to the single wire welding, the arc length of L-arc increased and the welding operating point changed in twin wire welding. [ABSTRACT FROM AUTHOR]