Abstract
- At first, the receiving system of the Tianma 65m radio telescope (TM65m in brief) and its noise characteristics at the L, S, C, and X four frequency bands are described. Then, a few measuring methods of system noise temperature are discussed, and the major factors affecting the noise temperature measurement are analyzed, including the errors caused by the non-linearity, feed network insertion loss, mismatch, and so on. With the Y-factor method the noise temperature of the noise source calibrated in the laboratory is verified, indicating that its accuracy attains ∼0.2K. Finally, the system noise temperatures actually measured at the four frequency bands and an analysis on the result are given. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02751062
- Volume :
- 39
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- Chinese Astronomy & Astrophysics
- Publication Type :
- Academic Journal
- Accession number :
- 108678587
- Full Text :
- https://doi.org/10.1016/j.chinastron.2015.07.010