Back to Search Start Over

Experimental study on natural circulation precooling of cryogenic pump system with gas phase inlet reflux configuration

Authors :
Chen, G.B.
Zhong, Y.K.
Zheng, X.L.
Li, Q.F.
Xie, X.M.
Gan, Z.H.
Huang, Y.H.
Tang, K.
Kong, B.
Qiu, L.M.
Source :
Cryogenics. Dec2003, Vol. 43 Issue 12, p693. 6p.
Publication Year :
2003

Abstract

A novel gas-phase inlet configuration in the natural circulation system instead of the liquid-phase inlet is introduced to cool down a cryogenic pump system from room temperature to cryogenic temperatures, effectively. The experimental apparatus is illustrated and test process is described. Heat transfer and pressure drop data during the cool-down process are recorded and portrayed. By contrast with liquid-phase inlet configuration, experimental results demonstrate that the natural circulation with the gas-phase inlet configuration is an easier and more controllable way to cool down the pump system and maintain it at cryogenic temperatures. [Copyright &y& Elsevier]