Back to Search
Start Over
Intensity modulated proton therapy.
- Source :
-
British Journal of Radiology . Jul2015, Vol. 88 Issue 1051, p1-16. 16p. - Publication Year :
- 2015
-
Abstract
- Intensity modulated proton therapy (IMPT) implies the electromagnetic spatial control of well-circumscribed "pencil beams" of protons of variable energy and intensity. Proton pencil beams take advantage of the charged-particie Bragg peak-the characteristic peak of dose at the end of range-combined with the modulation of pencil beam variables to create target-local modulations in dose that achieves the dose objectives. IMPT improves on X-ray intensity modulated beams (intensity modulated radiotherapy or volumetric modulated arc therapy) with dose modulation along the beam axis as well as lateral, in-field, dose modulation. The clinical practice of IMPT further improves the healthy tissue vs target dose differential in comparison with X-rays and thus allows increased target dose with dose reduction elsewhere. In addition, heavy-charged-particle beams allow for the modulation of biological effects, which is of active interest in combination with dose "painting" within a target. The clinical utilization of IMPT is actively pursued but technical, physical and clinical questions remain. Technical questions pertain to control processes for manipulating pencil beams from the creation of the proton beam to delivery within the patient within the accuracy requirement. Physical questions pertain to the interplay between the proton penetration and variations between planned and actual patient anatomical representation and the intrinsic uncertainty in tissue stopping powers (the measure of energy loss per unit distance). Clinical questions remain concerning the impact and management of the technical and physical questions within the context of the daily treatment delivery, the clinical benefit of IMPT and the biological response differential compared with X-rays against which clinical benefit will be judged. It is expected that IMPT will replace other modes of proton field delivery. Proton radiotherapy, since its first practice 50 years ago, always required the highest level of accuracy and pioneered volumetric treatment planning and imaging at a level of quality now standard in X-ray therapy IMPT requires not only the highest precision tools but also the highest level of system integration of the services required to deliver high-precision radiotherapy. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00071285
- Volume :
- 88
- Issue :
- 1051
- Database :
- Academic Search Index
- Journal :
- British Journal of Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 108520329
- Full Text :
- https://doi.org/10.1259/bjr.20150195