Back to Search Start Over

小管径超声波流量计去噪方法.

Authors :
WEN Wen
ZONG Guanghua
YU Yang
SUN Liang
Source :
Chinese Space Science & Technology / Zhongguo Kongjian Kexue Jishu. Apr2015, Vol. 35 Issue 2, p77-83. 7p.
Publication Year :
2015

Abstract

The noise will directly affect the accuracy of the ultrasonic flow meter. The sources of noise inside the small pipe ultrasonic flow meter were analyzed. Considering the critical real-time measurement for the flow meter, a method of directly denoising the transit-time difference data was proposed. It avoided sampling and analyzing the original ultrasonic signal, which might lead to the poor performance of real-time measurement. For different noise sources, two different kinds of filters were applied. The wavelet filter was chosen as the first denoisng filter, which used a hard thresholding to reduce error from the random noise. A median filter and a mean filter were combined as the second denoisng filter to reduce error from the acoustic noise. The flow rate measurement experiment was implemented to verify the validity of the proposed denoising method. The results show that the instantaneous measurement error can be less than 1% after denoising. [ABSTRACT FROM AUTHOR]

Details

Language :
Chinese
ISSN :
1000758X
Volume :
35
Issue :
2
Database :
Academic Search Index
Journal :
Chinese Space Science & Technology / Zhongguo Kongjian Kexue Jishu
Publication Type :
Periodical
Accession number :
108514591
Full Text :
https://doi.org/10.3780/j.issn.1000-758X.2015.02.011