Back to Search Start Over

Permanent pacemaker implantation after transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function.

Authors :
Urena, Marina
Webb, John G
Tamburino, Corrado
Muñoz-García, Antonio J
Cheema, Asim
Dager, Antonio E
Serra, Vicenç
Amat-Santos, Ignacio J
Barbanti, Marco
Immè, Sebastiano
Briales, Juan H Alonso
Benitez, Luis Miguel
Al Lawati, Hatim
Cucalon, Angela Maria
García Del Blanco, Bruno
López, Javier
Dumont, Eric
Delarochellière, Robert
Ribeiro, Henrique B
Nombela-Franco, Luis
Source :
Circulation. 3/18/2014, Vol. 129 Issue 11, p1233-1243. 11p.
Publication Year :
2014

Abstract

BACKGROUND: Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS: A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS: The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ~=2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00097322
Volume :
129
Issue :
11
Database :
Academic Search Index
Journal :
Circulation
Publication Type :
Academic Journal
Accession number :
107894403
Full Text :
https://doi.org/10.1161/CIRCULATIONAHA.113.005479