Back to Search Start Over

The efficacy and integrity of shape memory alloy staples and bone anchors with ligament tethers in the fusionless treatment of experimental scoliosis.

Authors :
Braun JT
Akyuz E
Ogilvie JW
Bachus KN
Braun, John T
Akyuz, Ephraim
Ogilvie, James W
Bachus, Kent N
Source :
Journal of Bone & Joint Surgery, American Volume. Sep2005, Vol. 87 Issue 9, p2038-2051. 14p.
Publication Year :
2005

Abstract

<bold>Background: </bold>Scoliosis is a complex three-dimensional deformity with limited treatment options. Current treatments present potential problems that may be addressed with use of fusionless techniques for the correction of scoliosis. However, there are few data comparing the efficacy of different fusionless implant strategies in controlling scoliosis or on the integrity of rigid compared with flexible devices in an in vivo setting over time. The objective of this study was to compare the efficacy and integrity of rigid and flexible anterior thoracic tethers used to treat experimental scoliosis.<bold>Methods: </bold>Experimental scoliosis was created in twenty-four Spanish Cross-X female goats and was subsequently treated with either anterior shape memory alloy staples or anterior ligament tethers attached to bone anchors. Serial radiographs were analyzed to determine the efficacy of the implants in controlling scoliosis progression as well as the integrity of the implants at study completion. After the goats were killed, the implants were analyzed with use of three quantitative indices of implant integrity and implant pullout testing.<bold>Results: </bold>Over the treatment period, scoliosis progressed from 77.3 degrees to 94.3 degrees in the goats treated with staples and was corrected from 73.4 degrees to 69.9 degrees in the goats treated with bone anchors, with loosening of eighteen of forty-two staples (two of the eighteen dislodged) and evidence of drift in two of forty-nine anchors. Histologic sections revealed a consistent halo of fibrous tissue around the staple tines but well-fixed bone anchors at all sites. Pullout testing demonstrated that bone anchors had greater strength than staples initially and at the study completion, with an increase in bone anchor fixation over the course of the study.<bold>Conclusions: </bold>In this scoliosis model, the flexible ligament tethers attached to bone anchors demonstrated greater efficacy and integrity than the more rigid shape memory alloy staples. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00219355
Volume :
87
Issue :
9
Database :
Academic Search Index
Journal :
Journal of Bone & Joint Surgery, American Volume
Publication Type :
Academic Journal
Accession number :
105906141