Back to Search Start Over

Ghost imaging based on Pearson correlation coefficients.

Authors :
Yu Wen-Kai
Yao Xu-Ri
Liu Xue-Feng
Li Long-Zhen
Zhai Guang-Jie
Source :
Chinese Physics B. May2015, Vol. 24 Issue 5, p1-1. 1p.
Publication Year :
2015

Abstract

Correspondence imaging is a new modality of ghost imaging, which can retrieve a positive/negative image by simple conditional averaging of the reference frames that correspond to relatively large/small values of the total intensity measured at the bucket detector. Here we propose and experimentally demonstrate a more rigorous and general approach in which a ghost image is retrieved by calculating a Pearson correlation coefficient between the bucket detector intensity and the brightness at a given pixel of the reference frames, and at the next pixel, and so on. Furthermore, we theoretically provide a statistical interpretation of these two imaging phenomena, and explain how the error depends on the sample size and what kind of distribution the error obeys. According to our analysis, the image signal-to-noise ratio can be greatly improved and the sampling number reduced by means of our new method. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16741056
Volume :
24
Issue :
5
Database :
Academic Search Index
Journal :
Chinese Physics B
Publication Type :
Academic Journal
Accession number :
102353238
Full Text :
https://doi.org/10.1088/1674-1056/24/5/054203