Detection of Airgap Eccentricity for Permanent Magnet Synchronous Motors Based on the d-Axis Inductance.
- Source :
-
IEEE Transactions on Power Electronics . May2012, Vol. 27 Issue 5, p2605-2612. 8p. - Publication Year :
- 2012
-
Abstract
- The majority of the work performed for detecting eccentricity faults for permanent magnet synchronous motors (PMSM) focus on motor current signature analysis (MCSA), as it provides continuous online monitoring with existing current sensors. However, MCSA cannot be applied under nonstationary conditions and cannot distinguish faults with load torque oscillations, which are limitations for many PMSM drive applications. In this paper, it is shown that the d-axis inductance L decreases with an increase in the severity of eccentricity due to the change in the degree of magnetic saturation, and it is proposed as a new fault indicator. The inverter can be used to perform a standstill test automatically whenever the motor is stopped to measure L for eccentricity testing independent of load variations or oscillations, which is not possible with MCSA. An finite element and experimental study on a 10-hp PMSM verifies that eccentricity can be detected independent of the load with high sensitivity and reliability. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 08858993
- Volume :
- 27
- Issue :
- 5
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Power Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 101264297
- Full Text :
- https://doi.org/10.1109/TPEL.2011.2176145