1. Theoretical Analysis of a Magnetic Shielding System Combining Active and Passive Modes.
- Author
-
Meng, Qingzhi, Wang, Zelin, Lin, Qijing, Ju, Dengfeng, Liang, Xianfeng, and Xian, Dan
- Subjects
- *
GEOMAGNETISM , *IRON-nickel alloys , *ELECTROMAGNETS , *ELECTROMAGNETIC interference , *ELECTRIC power distribution grids , *MAGNETIC fields , *ELECTROMAGNETIC shielding , *MAGNETIC shielding - Abstract
Considering the magnetic shielding requirements of both geomagnetic field and 50 Hz power-line frequency in the complex working conditions of the power grid, an electromagnetic shielding system combining active and passive modes is proposed in this article. A three-dimensional Helmholtz coil with a magnetic shielding barrel nested inside is established by the COMSOL simulation tool, and the magnetic shielding efficiency of the system is analyzed. Comparing different materials, the simulation results indicate that permalloy alloy exhibits better shielding performance than pure iron and nickel materials. Additionally, the overall shielding efficiency of the shielding barrel increases linearly with the number of multiple layers. Under the combined active and passive electromagnetic shielding conditions, the system achieves a shielding efficiency of SE = 113.98 dB, demonstrating excellent performance in shielding both AC and DC interference magnetic fields. This study provides theoretical guidance for the construction of magnetic shielding systems in electromagnetic interference environment. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF