15 results on '"de la Cruz JE"'
Search Results
2. Women's dyspareunia after childbirth: a case study in a hospital in Acapulco, Mexico.
- Author
-
Solana-Arellano E, Villegas-Arrizon A, Legorreta-Soberanis J, Cárdenas-Turanzas M, de la Cruz JE, and Andersson N
- Abstract
OBJECTIVE: To identify the factors associated with dyspareunia, during the 60-180 days following childbirth, in women with a history of one or two childbirths. METHODS: A case study of 304 women, matched by age and parity who visited family planning services in a hospital in Acapulco, State of Guerrero, Mexico, 60-180 days after giving birth. A questionnaire was administered to assess socioeconomic status (age, level of education, partner's level of education, marital status, employment, social security, and homeownership), obstetric history (type of birth, parity, location of the birth, tearing, episiotomy, and complications), and gynecological status (constricted introitus, scar tissue at the episiotomy site, symptoms of vaginitis, vaginal dryness, contraceptive use, and breast feeding duration). Cases were defined as those women who related pain, burning, or bleeding following vaginal intercourse after childbirth. An unconditional logistic regression model was applied and odd ratios (OR) and 95% confidence interval were calculated. RESULTS: Of the 368 women who had reinitiated sexual relations, 152 (41.3%) mentioned dyspareunia. The factors associated with dyspareunia were: an infection with or without episiorrhaphy dehiscence (OR = 34.09; CI95%: 10.59-109.78); symptoms of vaginitis (OR = 7.43; CI95%: 3.68-14.99); tightness in the introitus of the vagina (OR = 6.38; CI95%: 2.92-13.94), and breast feeding exclusively (OR = 4.86; CI95%: 2.44- 9.69). CONCLUSIONS: Dyspareunia was related to complications with episiotomy and its possible sequelae, such as infection, episiorrhaphy dehiscence, and constricted introitus. More attention should be given to the episiotomy site during the postpartum period and greater selectivity is needed when deciding which women require an episiotomy. [ABSTRACT FROM AUTHOR]
- Published
- 2008
3. EARLY FLUID PLUS NOREPINEPHRINE RESUSCITATION DIMINISHES KIDNEY HYPOPERFUSION AND INFLAMMATION IN SEPTIC NEWBORN PIGS.
- Author
-
Fanous MS, de la Cruz JE, Michael OS, Afolabi JM, Kumar R, and Adebiyi A
- Subjects
- Animals, Swine, Inflammation, Kidney metabolism, Renal Circulation, Glomerular Filtration Rate, Sepsis therapy, Sepsis physiopathology, Animals, Newborn, Norepinephrine, Resuscitation methods, Fluid Therapy methods, Acute Kidney Injury therapy, Acute Kidney Injury metabolism
- Abstract
Abstract: Sepsis is the most frequent risk factor for acute kidney injury (AKI) in critically ill infants. Sepsis-induced dysregulation of kidney microcirculation in newborns is unresolved. The objective of this study was to use the translational swine model to evaluate changes in kidney function during the early phase of sepsis in newborns and the impact of fluid plus norepinephrine resuscitation. Newborn pigs (3-7-day-old) were allocated randomly to three groups: 1) sham, 2) sepsis (cecal ligation and puncture) without subsequent resuscitation, and 3) sepsis with lactated Ringer plus norepinephrine resuscitation. All animals underwent standard anesthesia and mechanical ventilation. Cardiac output and glomerular filtration rate were measured noninvasively. Mean arterial pressure, total renal blood flow, cortical perfusion, medullary perfusion, and medullary tissue oxygen tension (mtPO 2 ) were determined for 12 h. Cecal ligation and puncture decreased mean arterial pressure and cardiac output by more than 50%, with a proportional increase in renal vascular resistance and a 60-80% reduction in renal blood flow, cortical perfusion, medullary perfusion, and mtPO 2 compared to sham. Cecal ligation and puncture also decreased glomerular filtration rate by ~79% and increased AKI biomarkers. Isolated foci of tubular necrosis were observed in the septic piglets. Except for mtPO 2 , changes in all these parameters were ameliorated in resuscitated piglets. Resuscitation also attenuated sepsis-induced increases in the levels of plasma C-reactive protein, proinflammatory cytokines, lactate dehydrogenase, alanine transaminase, aspartate aminotransferase, and renal NLRP3 inflammasome. These data suggest that newborn pigs subjected to cecal ligation and puncture develop hypodynamic septic AKI. Early implementation of resuscitation lessens the degree of inflammation, AKI, and liver injury., Competing Interests: The authors report no conflicts of interest., (Copyright © 2024 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Shock Society.)
- Published
- 2024
- Full Text
- View/download PDF
4. Cytotoxicity Assessment of a New Design for a Biodegradable Ureteral Mitomycin Drug-Eluting Stent in Urothelial Carcinoma Cell Culture.
- Author
-
Soria F, Martínez-Pla L, Aznar-Cervantes SD, de la Cruz JE, Fernández T, Pérez-Fentes D, Llanes L, and Sánchez-Margallo FM
- Abstract
Urothelial tumour of the upper urinary tract is a rare neoplasm, but unfortunately, it has a high recurrence rate. The reduction of these tumour recurrences could be achieved by the intracavitary instillation of adjuvant chemotherapy after nephron-sparing treatment in selected patients, but current instillation methods are ineffective. Therefore, the aim of this in vitro study is to evaluate the cytotoxic capacity of a new instillation technology through a biodegradable ureteral stent/scaffold coated with a silk fibroin matrix for the controlled release of mitomycin C as an anti-cancer drug. Through a comparative study, we assessed, in urothelial carcinoma cells in a human cancer T24 cell culture for 3 and 6 h, the cytotoxic capacity of mitomycin C by viability assay using the CCK-8 test (Cell counting Kit-8). Cell viability studies in the urothelial carcinoma cell line confirm that mitomycin C embedded in the polymeric matrix does not alter its cytotoxic properties and causes a significant decrease in cell viability at 6 h versus in the control groups. These findings have a clear biomedical application and could be of great use to decrease the recurrence rate in patients with upper tract urothelial carcinomas by increasing the dwell time of anti-cancer drugs.
- Published
- 2022
- Full Text
- View/download PDF
5. Interactive Effects of Copper-Doped Urological Implants with Tissue in the Urinary Tract for the Inhibition of Cell Adhesion and Encrustation in the Animal Model Rat.
- Author
-
Kram W, Rebl H, de la Cruz JE, Haag A, Renner J, Epting T, Springer A, Soria F, Wienecke M, and Hakenberg OW
- Abstract
The insertion of a ureteral stent provides acute care by restoring urine flow and alleviating urinary retention or dysfunction. The problems of encrustation, bacterial colonization and biofilm formation become increasingly important when ureteral stents are left in place for a longer period of time. One way to reduce encrustation and bacterial adherence is to modify the stent surface with a diamond-like carbon coating, in combination with copper doping. The biocompatibilities of the Elastollan
® base material and the a-C:H/Cu-mulitilayer coating were tested in synthetic urine. The copper content in bladder tissue was determined by atomic absorption spectroscopy and in blood and in urine by inductively coupled plasma mass spectrometry. Encrustations on the materials were analyzed by scanning electron microscopy, energy dispersive X-ray spectroscopy and Fourier transform infrared spectroscopy. A therapeutic window for copper ions of 0.5-1.0 mM was determined to kill bacteria without affecting human urothelial cells. In the rat animal model, it was found that copper release did not reach toxic concentrations in the affecting tissue of the urinary tract or in the blood. The encrustation behavior of the surfaces showed that the roughness of the amorphous carbon layer with the copper doping is probably the causal factor for the higher encrustation.- Published
- 2022
- Full Text
- View/download PDF
6. Assessment of a Coated Mitomycin-Releasing Biodegradable Ureteral Stent as an Adjuvant Therapy in Upper Urothelial Carcinoma: A Comparative In Vitro Study.
- Author
-
Soria F, Aznar-Cervantes SD, de la Cruz JE, Budia A, Aranda J, Caballero JP, Serrano Á, and Sánchez Margallo FM
- Abstract
A major limitation of the treatment of low-grade upper tract urothelial carcinoma is the difficulty of intracavitary instillation of adjuvant therapy. Therefore, the aim of this in vitro study was to develop and to assess a new design of biodegradable ureteral stent coated with a silk fibroin matrix for the controlled release of mitomycin C as a chemotherapeutic drug. For this purpose, we assessed the coating of a biodegradable ureteral stent, BraidStent
® , with silk fibroin and subsequently loaded the polymeric matrix with two formulations of mitomycin to evaluate its degradation rate, the concentration of mitomycin released, and changes in the pH and the weight of the stent. Our results confirm that the silk fibroin matrix is able to coat the biodegradable stent and release mitomycin for between 6 and 12 h in the urinary environment. There was a significant delay in the degradation rate of silk fibroin and mitomycin-coated stents compared to bare biodegradable stents, from 6-7 weeks to 13-14 weeks. The present study has shown the feasibility of using mitomycin C-loaded silk fibroin for the coating of biodegradable urinary stents. The addition of mitomycin C to the coating of silk fibroin biodegradable stents could be an attractive approach for intracavitary instillation in the upper urinary tract.- Published
- 2022
- Full Text
- View/download PDF
7. Biodegradable ureteral stents: in vitro assessment of the degradation rates of braided synthetic polymers and copolymers.
- Author
-
de la Cruz JE, Soto M, Martínez-Plá L, Galán-Llopis JA, Sánchez-Margallo FM, and Soria F
- Abstract
Objectives: The control and predictability of degradation rates and the absence of obstructive phenomena are two main challenges for research regarding biodegradable ureteral stents. The objectives are to assess the degradation performance and safety of braided combinations of three synthetic biodegradable polymers and copolymers; and to evaluate the interference of a heparin dip coating on degradation and bacterial colonization., Methods: The hydrolysis of polyglycolic acid (PGA), poly lactic-co-glycolic acid (PLGA) and Glycomer™ 631 is assessed in this in vitro study that comprises ten groups. Stent samples present a braided arrangement and are incubated in porcine urine that undergoes analysis and exchange every 48 h until degradation. Coating is carried out with sodium heparin via dip coating and determination of the heparin release is carried out by ELISA test. Variables of study are stent mass, mass fold change, degradation time, bacterial colonization and concentration of heparin released in artificial urine., Results: There is statistical significance in degradation times between all materials except between the Glycomer™ 631 alone and combined with PGA. Mass fold change analysis of the Glycomer™ 631 evidences an increasing trend of its mass during degradation. The combination of Glycomer™ 631 and PGA presents a progressive and gradual degradation, where PGA degrades at week 3 while Glycomer™ 631 remains intact until its fragmentation at the late stage of degradation. Heparin coating has no significant impact on mean degradation times and trends in any group, nor on bacteriuria rates; heparin concentration decreases significantly after 72 h. Products of degradation are released steadily with minimum dimensions., Conclusions: The combination of synthetic biodegradable polymers and copolymers with different degradation rates provides a gradual staged degradation. Heparin dip coating is a safe and feasible technique to coat biodegradable ureteral stents without interfering in degradation rates although it does not have a significant effect on the onset of bacterial colonization., Competing Interests: None., (AJCEU Copyright © 2022.)
- Published
- 2022
8. Heparin coating in biodegradable ureteral stents does not decrease bacterial colonization-assessment in ureteral stricture endourological treatment in animal model.
- Author
-
Soria F, de La Cruz JE, Fernandez T, Budia A, Serrano Á, and Sanchez-Margallo FM
- Abstract
Background: We assessed an antireflux biodegradable heparin-coated ureteral stent (BraidStent
® -H) in an animal model comparative study after endoscopic treatment of ureteral strictures., Methods: A total of 24 female pigs underwent initial endoscopic, nephrosonographic, and contrast fluoroscopy assessment of the urinary tract. Afterward, unilateral laparoscopic ureteral stricture model was performed. Three weeks later, the animals underwent laser endoureterotomy and were randomly assigned to Group-I, in which a double-pigtail stent was placed for 6 weeks, or Group-II, in which a BraidStent®-H was placed. Follow-up was carried out by ultrasonography, contrast fluoroscopy, ureteroscopy, urinalysis and bacteriuria assessment at 3, 6, 12 and 5 months. Finally, a pathological study of the urinary system was performed., Results: There were no animals in Group-II with vesicoureteral reflux, with significance at 6 weeks with Group-I. Distal ureteral peristalsis was maintained in 50-75% in Group-II at 1-6 weeks. The 91.7% of stents in Group-II were degraded between 3-6 weeks, without obstructive fragments. Bacteriuria in Group II was 33.3-50% at 3 and 6 weeks. The global success rate by groups was 91.6% and 87.5% in groups I and II, respectively, with no statistical significance., Conclusions: BraidStent® -H has been shown to be as efficacious as current ureteral stents in the treatment of benign ureteral strictures following laser endoureterotomy. In addition, it reduces the morbidity associated with current stents and has a homogeneous and predictable degradation rate of about 6 weeks, with no obstructive fragments. Future studies are required to improve the antibacterial coating to reduce BraidStent® -H contamination in view of the results obtained with the heparin coating., Competing Interests: Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at http://dx.doi.org/10.21037/tau-21-19). Dr. Soria reports that he has a patent EP2749311 issued to JUMISC. Dr. Sanchez-Margallo reports that he has a patent EP2749311 issued to JUMISC. The other authors have no conflicts of interest to declare., (2021 Translational Andrology and Urology. All rights reserved.)- Published
- 2021
- Full Text
- View/download PDF
9. Comparative assessment of biodegradable-antireflux heparine coated ureteral stent: animal model study.
- Author
-
Soria F, de La Cruz JE, Caballero-Romeu JP, Pamplona M, Pérez-Fentes D, Resel-Folskerma L, and Sanchez-Margallo FM
- Subjects
- Absorbable Implants, Animals, Disease Models, Animal, Female, Random Allocation, Swine, Bacteriuria prevention & control, Drug-Eluting Stents, Heparin analysis, Ureter surgery, Vesico-Ureteral Reflux prevention & control
- Abstract
Background: Double J ureteral stents are widely used on urological patients to provide drainage of the upper urinary tract. Unfourtunately, ureteral stents are not free from complications, as bacterial colonization and require a second procedure for removal. The purpose of the current comparative experimental study is to evaluate a new heparin-coated biodegradable antireflux ureteral stent (BraidStent®-H) to prevent urinary bacterial colonization., Methods: A total of 24 female pigs were underwent determination of bacteriuria and nephrosonographic, endoscopic and contrast fluoroscopy assessment of the urinary tract. Afterward, were randomly assigned animals to Group-I, in which a 5Fr double-pigtail ureteral stent was placed for 6 weeks, or Group-II, in which a BraidStent®-H was placed. Follow-up assessments were performed at 1, 3, 6, 8, 12 weeks. The final follow-up includes the above methods and an exhaustive pathological study of the urinary tract was accomplished after 20 weeks., Results: Bacteriuria findings in the first 48 h were significant between groups at 6 h and 12 h. Asymptomatic bacteriuria does not reach 100% of the animals in Group-II until 48 h versus Group-I where it appears at 6 h. The weekly bacteriuria mean rate was 27.7% and 44.4% in Group I and II respectively, without statistical significance. In Group II there were no animals with vesicoureteral reflux, with statistical significance at 3 and 6 weeks with Group-I. The 91.2% of stents in Group-II were degraded between 3 and 6 weeks, without obstructive fragments. Distal ureteral peristalsis was maintained in 66.6-75% in Group-II at 1-6 weeks., Conclusions: The heparin coating of BraidStent® allows an early decrease of bacterial colonization, but its effectiveness is low at the long term. Heparin coating did not affect scheduled degradation rate or size of stents fragments. BraidStent®-H avoids the side effects associated with current ureteral stents, thus should cause less discomfort to patients.
- Published
- 2021
- Full Text
- View/download PDF
10. Assessment of the Grades of Vesicoureteral Reflux in Stented Ureters: An Experimental Study.
- Author
-
de la Cruz JE, Fernández I, Sanz-Migueláñez JL, Fernández-Aparicio T, Sánchez-Margallo FM, and Soria F
- Subjects
- Animals, Female, Postoperative Complications classification, Severity of Illness Index, Swine, Vesico-Ureteral Reflux classification, Postoperative Complications diagnosis, Postoperative Complications etiology, Stents adverse effects, Ureter surgery, Vesico-Ureteral Reflux diagnosis, Vesico-Ureteral Reflux etiology
- Abstract
Introduction: The aim of this experimental study is to assess, in a porcine model, the onset and grades of vesicoureteral reflux associated with ureteral stents., Methods: Twenty-four female porcine models were used. A 4.7-Fr ureteral stent was placed in all right ureters and kept in place for 6 weeks. Follow-ups were performed on weeks 1, 3, 6, and 12. Ultrasonography, cystoscopy, and fluoroscopy were used to analyze grade of hydronephrosis, presence and grade of vesicoureteral reflux, bacteriuria, and macroscopic changes of the ureteral orifices. Vesicoureteral reflux was classified using a modification of the International Reflux Study Committee grades., Results: 91.7% animals present vesicoureteral reflux, 89.5% grade IA, 3.5% grade IB, and 7% grade II. There is a significant increase in reflux during follow-ups at 3 and 6 weeks, whereas 6 weeks after removal, 26.3% of the ureters still present vesicoureteral reflux. Hydronephrosis and macroscopic changes of the ureteral orifice increase significantly with stenting, but there is no significant association between them and vesicoureteral reflux; the relationship between bacteriuria and the presence of vesicoureteral reflux is not significant either., Conclusion: Vesicoureteral reflux caused by ureteral stents in an animal model is mostly low grade and mainly affects the distal ureter., (© 2021 S. Karger AG, Basel.)
- Published
- 2021
- Full Text
- View/download PDF
11. Response to Chow and Venkatesh re: "Experimental Assessment of New Generation of Ureteral Stents: Biodegradable and Antireflux Properties" (J Endourol 2020;34(3):366; DOI: 10.1089/end.2019.0812).
- Author
-
de la Cruz JE, Sanchez Margallo FM, and Soria F
- Subjects
- Stents, Ureter surgery
- Published
- 2020
- Full Text
- View/download PDF
12. Experimental Assessment of New Generation of Ureteral Stents: Biodegradable and Antireflux Properties.
- Author
-
Soria F, de la Cruz JE, Budia A, Serrano A, Galan-Llopis JA, and Sanchez-Margallo FM
- Subjects
- Animals, Disease Models, Animal, Female, Laparoscopy, Postoperative Complications prevention & control, Swine, Vesico-Ureteral Reflux prevention & control, Absorbable Implants, Stents, Ureteral Obstruction surgery
- Abstract
Objective: The aim was to assess a new biodegradable and antireflux intraureteral stent (BraidStent
® ) design in a swine model after ureteral laparoscopic operation. Materials and Methods: A total of 24 female pigs underwent initial endoscopic, nephrosonographic, and contrast fluoroscopy assessment of the urinary tract. Afterward, unilateral ureteropelvic junction obstruction was performed by laparoscopic approach. Six weeks later, the animals underwent laparoscopic Anderson-Hynes pyeloplasty, and were randomly assigned to Group-I, in which a double-pigtail ureteral stent was inserted for 6 weeks, or Group-II, in which a BraidStent® , a biodegradable intraureteral stent design, was placed. Follow-up assessments were performed at 3 and 6 weeks and 5 months. Results: In terms of therapeutic success, complete resolution was observed in 91.6% of Group-I animals and 88.8% in Group-II. No evidence of vesicoureteral reflux (VUR) was observed in Group-II animals and statistical significance in VUR and ureteral orifice damage were observed between groups. BraidStent® degradation occurred in a controlled manner between 3 and 6 weeks, without obstructive fragments. Distal ureteral peristalsis was maintained in 66.6% and 83.3% in Group-II at 3 and 6 weeks of follow-up, respectively. In Group-II, the positive bacteriuria rate was 41.6% and the migration rate 25%. Pathological assessment showed a significant improvement in ureteral healing in Group-II vs Group-I. Conclusions: The results of this comparative study in a porcine model indicate that the intraureteral BraidStent performed similarly to conventional ureteral stents. It avoids complete ureteral length intubation, the adverse effects associated with conventional ureteral stents, and maintains a high level of distal ureteral peristalsis. Moreover, the BraidStent® exhibited a predictable and controlled degradation rate and did not cause any obstructive fragments. However, further studies are needed to improve the anchoring system and reduce the risk of bacterial colonization.- Published
- 2020
- Full Text
- View/download PDF
13. Antireflux ureteral stent proof of concept assessment after minimally invasive treatment of obstructive uropathy in animal model.
- Author
-
Soria F, Morcillo E, de la Cruz JE, Serrano A, Estebanez J, Sanz JL, Chicharro J, Pamplona M, and Sanchez-Margallo FM
- Subjects
- Animals, Disease Models, Animal, Female, Minimally Invasive Surgical Procedures, Proof of Concept Study, Random Allocation, Swine, Ureteral Obstruction etiology, Urologic Surgical Procedures methods, Vesico-Ureteral Reflux complications, Stents, Ureteral Obstruction surgery, Vesico-Ureteral Reflux surgery
- Abstract
Objectives: To assess the efficacy of a new anti-reflux intraureteral stent design in a swine model after minimally invasive treatment of ureteral stricture to reduce ureteral stent morbidity, previous to manufacture this design in a biodegradable fashion., Methods: Twenty-eight female pigs were included. The study began with a cystoscopic, nephrosonographic and contrast fluoroscopic assessment. Afterwards, obstructive uropathy model in right ureter was created. Obstruction was confirmed 6 weeks later and animals were randomly distributed into 2 groups. Group I underwent laser endopyelotomy and Group-II laparoscopic pyeloplasty A 3Fr anti-reflux intraureteral stent was placed 6 weeks. Follow-up evaluations were performed at 3-6 weeks. The final follow-up was completed at 5 months and included the aforementioned diagnostic methods and pathological study., Results: None of the study animals showed any vesicoureteral reflux signs or ureteral orifice injury. There were no urinomas or ureteric fistulas. The dislodgement rate was 10.7%. After 6 weeks of stenting, 71.4% of ureters showed ureteral peristalsis below the stent, and 100% at the final follow-up. After pathological assessment, no differences were shown at UPJ and healing in the incised area was correct in both groups., Conclusions: The new stent design avoids vesicoureteral reflux and bladder trigone irritation, consequently might reduce morbidity associated with double pigtail ureteral stents. This study also shows that it is only necessary temporary scaffolding the incised ureteral segment and not the entire length of the ureter after minimally invasive surgery. It is also necessary to manufacture this design in a biodegradable material, thus avoiding its removal.
- Published
- 2018
14. [Antirreflux ureteral catheters.]
- Author
-
Soria F, de la Cruz JE, Morcillo E, Rioja J, and Sánchez-Margallo FM
- Subjects
- Equipment Design, Humans, Urinary Catheters, Vesico-Ureteral Reflux prevention & control
- Abstract
Double-J ureteral stents disposal is associated with the appearance of side effects in up to 90% of the patients. The main causes of these symptoms are related to stent's design and the materials they are manufactured from. Vesicoureteral reflux and bladder trigone irritation are the etiopathogenic causes of ureteral stents associated morbidity. Due to this, and in order to improve patients' quality of life, stents that avoid reflux have been developed. Among anti-reflux designs, the first was a double-J stent the bladder tip of which is provided with a polymeric membrane that prevents retrograde flow of urine through its internal drainage channel. This design showed satisfactory vesicaresults, although not statistically significant. Their use in renal transplantation has also been assessed not only to decrease morbidity and ascending infection but also to improve graft survival. Other designs try to thin the distal end and even change it to a surgical suture thread, with the aim of eliminating the internal drainage channel in order to cause the minimum interference with the UVJ. Recently, two prototypes were evaluated in animal models and have achieved reduction of VUR. The first consists of a valve attached to the distal end of a traditional double-J stent, acting as a backflow prevention device. The second design is an intra-ureteral stent that acts like a double-J stent, but without crossing the UVJ and therefore preventing reflux completely. Nowadays, the use of these devices is not implemented in hospitals due to the absence of scientific evidence supporting the superiority of these designs over conventional stents.
- Published
- 2016
15. Verification jig for implant-supported prostheses: A comparison of standard impressions with verification jigs made of different materials.
- Author
-
De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, and Tallents RH
- Subjects
- Methylmethacrylates, Reproducibility of Results, Acrylic Resins, Dental Implants, Dental Impression Technique, Dental Instruments, Dental Prosthesis Design instrumentation, Dental Prosthesis, Implant-Supported, Models, Dental
- Abstract
Statement of Problem: Implant verification jigs are routinely used during the fabrication of implant-supported prostheses. The dimensional accuracy of these jigs is unknown., Purpose: The purposes of this study were to (1) compare the dimensional accuracy of verification jigs with that of conventional impression procedures and (2) measure the dimensional accuracy of 3 resin materials used to fabricate verification jigs., Materials and Methods: Thirty verification jigs and 20 impressions were made of 3 externally hexed Steri-Oss implants in a master stone base according to the following groups (n = 10 per group): (Group 1) Jig: GC pattern resin; (Group 2) Jig: Duralay resin; (Group 3) Jig: Triad gel resin; (Group 4) Impression: closed-tray impression copings; and (Group 5) Impression: open-tray impression copings. A stone base was fabricated for each experimental jig and impression. Master stone base and experimental stone bases were measured with the following methods: X and Y coordinates of each implant center were obtained with a traveling microscope by averaging the X and Y coordinates of the implant external hex corners. The origins of the coordinates during measurement of each base were arbitrary. Distances between implant center points were calculated by use of the Pythagorean theorem. Vertical measurements (Z-plane) were obtained with a digital caliper at the 2 terminal-implant locations. Interimplant distances and vertical measurements were subtracted from those of the master base, and the resultant distortion values were analyzed with analysis of variance and Tukey Studentized range tests. Statistical significance was set at P<.05., Results: Verification jigs were not significantly more accurate than standard impression procedures. Open-tray impressions showed a significantly greater vertical distortion (Z-R location: 262 +/- 158 microm; P=.0001; Z-L location 333 +/- 189; P=.0001) compared with the other groups. Triad gel jigs showed a significantly greater distortion in one interimplant distance (C-L) than closed-tray impressions (P=.04), whereas Duralay jigs exhibited significant greater distortion than closed-tray and open-tray impressions in the interimplant distance R-C (P=.006). Although not significantly different from other groups, the closed-tray group showed the lowest mean distortion values in all measurements., Conclusion: Within the limitations of this study, the accuracy provided by verification jigs was not significantly superior to standard impression procedures. The results suggest that jig fabrication does not improve the dimensional accuracy of stone casts. Open-tray impressions showed a significantly greater inaccuracy in the vertical plane.
- Published
- 2002
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.