1. Brazilian air traffic controllers exhibit excessive sleepiness.
- Author
-
Ribas VR, de Almeida CÂV, Martins HAL, Alves CFO, Alves MJPC, Carneiro SMO, Ribas VR, de Vasconcelos CAC, Sougey EB, and de Castro RM
- Abstract
Excessive sleepiness (ES) is an increased tendency to initiate involuntary sleep for naps at inappropriate times., Objective: The objective of this study was to assess ES in air traffic controllers (ATCo)., Methods: 45 flight protection professionals were evaluated, comprising 30 ATCo, subdivided into ATCo with ten or more years in the profession (ATCo≥10, n=15) and ATCo with less than ten years in the profession (ATCo<10, n=15) and 15 aeronautical information services operators (AIS), subdivided into AIS with ten years or more in the profession (AIS≥10, n=8) and AIS with less than ten years in the profession (AIS<10, n=7), who were included as the control group. The Epworth Sleepiness Scale and Maintenance of Wakefulness Test were used for evaluating subjective and objective excessive sleepiness. Kruskal-Wallis was used for ES and Mann-Whitney for sleep latency (SL), collection time in minutes (mins), and expressed as Median (Minimum-Maximum), p<0.05., Results: ATCo≥10 12 (6-14) mins and ATCo<10 10 (1-15) mins showed greater sleepiness compared to CONTROL1 7 (3-8) mins and CONTROL2 6 (4-6) mins, p=0.001*. A total of 77.27% of the ATCo and 16.67% of the AIS had an SL of less than 20 minutes. The ATCo presented an SL of 16.59 (3.25-40), lower than that of the AIS of 31.71 (10.63-40) mins, p<0.05*., Conclusion: Brazilian air traffic controllers exhibit excessive sleepiness., Competing Interests: Disclosure: The authors reports no conflicts of interest.
- Published
- 2011
- Full Text
- View/download PDF