1. Evaluation of a novel triplex immunochromatographic test for rapid simultaneous detection of norovirus, rotavirus, and adenovirus on a single strip test
- Author
-
Hiroshi Ushijima, Ngan Thi Kim Pham, Sheikh Ariful Hoque, Akiko Nomura, Kattareeya Kumthip, Yuko Shimizu-Onda, Shoko Okitsu, Kimiko Kawata, Nozomu Hanaoka, Werner EG Müller, Niwat Maneekarn, Satoshi Hayakawa, and Pattara Khamrin
- Subjects
Diarrhea ,Immunochromatographic test ,Japan ,Rotavirus ,Adenovirus ,Norovirus ,Infectious and parasitic diseases ,RC109-216 ,Public aspects of medicine ,RA1-1270 - Abstract
Background: Acute gastroenteritis is one of the major causes of morbidity and mortality in young children worldwide. Among these, rotavirus, norovirus, and adenovirus have been reported as the primary viral pathogens associated with the disease. Rapid diagnosis of viral pathogens is crucial when diarrhea outbreaks occur to ensure the timely administration of appropriate treatment and control measures. Methods: We evaluated three immunochromatographic test kits designed for the detection of norovirus, rotavirus, and adenovirus in 71 stool specimens collected from children with diarrhea who visited clinics in Japan. The first kit is a triplex immunochromatographic test kit designed for simultaneous detections of norovirus, rotavirus, and adenovirus on a single strip (this kit was referred to as IC-A). The other two immunochromatographic test kits are a dual detection kit for rotavirus and adenovirus, and a single detection kit for norovirus (IC-B). The RT-PCR/PCR was used as the gold standard method. Results: The results revealed that both IC-A and IC-B kits exhibited the same level of sensitivity of detection for rotavirus (72.7%) and adenovirus (22.7%), although the detection rate was lower than that of the RT-PCR/PCR method. However, there was a slight difference in the sensitivity of detection for norovirus between IC-A and IC-B, at 86.7% and 93.3%, respectively. The sensitivity of detection for adenovirus of both kits was relatively lower than those of RT-PCR method. This could be due to low viral load of adenovirus in clinical specimens below the detection limit of IC-A and IC-B kits. However, both immunochromatographic test kits (IC-A and IC-B) exhibited 100% specificity for norovirus, rotavirus, and adenovirus. Conclusions: The triplex immunochromatographic test kit (IC-A) designed for simultaneous detection of norovirus, rotavirus, and adenovirus has been proved to be more practical and convenient than the use of single or dual detection kits with more or less the same sensitivity and specificity of detections.
- Published
- 2024
- Full Text
- View/download PDF