10 results on '"Yi-Hung Ho"'
Search Results
2. Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps
- Author
-
Yi Hung Ho, Chih Han Chang, Yao Te Peng, Chih Wei Chang, Chun Ting Li, Pei Yuan Lee, and Yen Nien Chen
- Subjects
Models, Anatomic ,medicine.medical_specialty ,0206 medical engineering ,Tibia Fracture ,02 engineering and technology ,Bending ,Bone Nails ,law.invention ,Intramedullary rod ,Fractures, Bone ,03 medical and health sciences ,0302 clinical medicine ,law ,medicine ,Humans ,Computer Simulation ,Tibia ,skin and connective tissue diseases ,General Environmental Science ,Titanium ,Orthodontics ,030222 orthopedics ,integumentary system ,business.industry ,Reproducibility of Results ,Equipment Design ,020601 biomedical engineering ,Biomechanical Phenomena ,Fracture Fixation, Intramedullary ,Surgery ,Diaphysis ,medicine.anatomical_structure ,Nail (fastener) ,Fracture (geology) ,General Earth and Planetary Sciences ,Diaphyses ,Stress, Mechanical ,Deformation (engineering) ,business - Abstract
Introduction Elastic stable intramedullary nailing (ESIN) is a treatment strategy for the management of diaphyseal long-bone fractures in adolescents and children, but few studies have investigated the mechanical stability of tibial diaphyseal fractures treated with various degrees of prebending of the elastic nails. Therefore, the aim of this study was to compare the mechanical stability, including the gap deformation and nail dropping, of a tibia fracture with various fracture sites and fixed with various degrees of prebending of the elastic nails by the finite element method. Furthermore, the contribution of end caps to stability was taken into consideration in the simulation. Methods A tibia model was developed with a transverse fracture at the proximal, middle and distal parts of the diaphysis, and fixed with three degrees of prebending of elastic nails, including those equal to, two times and three times the diameter of the intramedullary canal. The outer diameter of the nail used in the computation was 3.5 mm, and the fractured tibia was fixed with two elastic double C-type nails. Furthermore, the proximal end of each nail was set to free or being tied to the surrounding bone by a constraint equation to simulate with or without using end caps. Results The results indicated that using end caps can prevent the fracture gap from collapsing by stopping the ends of the nails from dropping back in all prebending conditions and fracture patterns, and increasing the prebending of the nails to a degree three times the diameter of the canal reduced the gap shortening and the dropping distance of the nail end in those without using end caps under axial compression and bending. Insufficient prebending of the nails and not using end caps caused the gap to collapse and the nail to drop back at the entry point under loading. Conclusions Using end caps or increasing the prebending of the nails to three times the diameter of the canal is suggested to stop the nail from dropping back and thus produce a more stable structure, with less gap deformation, in the management of a simulated tibial diapyhseal fracture by using titanium elastic nails with a double C-shape.
- Published
- 2016
- Full Text
- View/download PDF
3. Effect of ankle kinesio taping on vertical jump with run-up and countermovement jump in athletes with ankle functional instability
- Author
-
Hong Wen Wu, Chih Han Chang, Yi Hung Ho, and Cheng Feng Lin
- Subjects
medicine.medical_specialty ,Functional instability ,biology ,business.industry ,Athletes ,Physical Therapy, Sports Therapy and Rehabilitation ,biology.organism_classification ,Sagittal plane ,Vertical jump ,medicine.anatomical_structure ,Kinesio taping ,Physical therapy ,Jump ,Ankle functional instability ,Medicine ,Original Article ,Force platform ,Ankle ,Ground reaction force ,business - Abstract
[Purpose] Limited research has been performed in spite of biomechanical evaluation of jump landing with kinesio taping. Therefore, the main objective of this study was to evaluate the effect of kinesio taping applied to athletes. In this study, the authors wished to investigate the effect of kinesio taping during a vertical jump with run-up and countermovement jump on ankle functional instability. [Subjects and Methods] Ten male athletes with ankle functional instability (FI) were recruited in this study from a college volleyball team. Each participant was requested to perform two tasks, the countermovement jump and vertical jump with run-up. Infrared high-speed cameras and force plates were used to assess the effect of ankle taping. [Results] The results showed that the peak ground reaction force in the sagittal plane during a vertical jump with run-up slowed down after kinesio taping and that the peak ankle plantar flexion moment in both types of jump also decreased. [Conclusion] In conclusion, this study proved the effect of kinesio taping on ankle functional instability, which was evaluated by measuring the vertical ground reaction force and peak plantar flexion moment. Its finding may allow us to provide some recommendations for athletes and trainers.
- Published
- 2015
- Full Text
- View/download PDF
4. Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures
- Author
-
Pei Yuan Lee, Chun Ting Li, Chih Han Chang, Yen Nien Chen, Chih Wei Chang, Yao Te Peng, and Yi Hung Ho
- Subjects
LONG BONE FRACTURE ,Materials science ,0206 medical engineering ,Long bone ,Biomedical Engineering ,Biophysics ,General Physics and Astronomy ,Dentistry ,chemistry.chemical_element ,02 engineering and technology ,Bone Nails ,Fractured bone ,Diaphyseal fracture ,law.invention ,Intramedullary rod ,03 medical and health sciences ,Fractures, Bone ,0302 clinical medicine ,law ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Computer Simulation ,Elasticity (economics) ,skin and connective tissue diseases ,Orthodontics ,Titanium ,030222 orthopedics ,integumentary system ,business.industry ,Torsion (mechanics) ,Reproducibility of Results ,Models, Theoretical ,020601 biomedical engineering ,Elasticity ,Biomechanical Phenomena ,medicine.anatomical_structure ,chemistry ,Diaphyses ,Stress, Mechanical ,business - Abstract
This study numerically investigated the deformation of titanium elastic nails prebent at various degrees during implantation into the intramedullary canal of fractured bones and the mechanism by which this prebending influenced the stability of the fractured bone. Three degrees of prebending the implanted portions of the nails were used: equal to, two times, and three times the diameter of the intramedullary canal. Furthermore, a simulated diaphyseal fracture with a 5-mm gap was created in the middle shaft portion of the bone fixed with two elastic nails in a double C-type configuration. End caps were simulated using a constraint equation. To confirm that the simulation process is able to present the mechanical response of the nail inside the intramedullary, an experiment was conducted by using sawbone for validation. The results indicated that increasing the degrees of nail prebending facilitated straightening the nails against the inner aspect of canal after implantation, with increase in stability under torsion. Furthermore, reducing nail prebending caused a larger portion of the nails to move closer to the loading site and center of bone after implantation; the use of end caps prevented the nail tips from collapsing and increased axial stability. End cap use was critical for preventing the nail tips from collapsing and for increasing the stability of the nails prebent at a degree equal to the diameter of the canal with insufficient frictional force between the nail and canal. Therefore, titanium elastic nail prebending in a double C-type configuration with a degree three times the diameter of the canal represents a superior solution for treating transverse fractures without a gap, whereas that with a degree equal to the diameter of the intramedullary canal and combined with end cap use represents an advanced solution for treating comminuted fractures in a diaphyseal long bone fracture.
- Published
- 2016
5. CONFIGURATION SET TO MOTION SIMULATION FOR BACKHAND STROKE OF TENNIS
- Author
-
Chung-Shun Hung, Li-Cheng Hsieh, Ran-Sing Chen, Hong-Wen Wu, and Yi-Hung Ho
- Subjects
Biomedical Engineering ,Biophysics ,Bioengineering - Abstract
Many people sustain injuries while playing tennis due to improper methods of impacting the ball and insufficient muscle warm-up. A common injury of playing the backhand stroke would be either elbow flexor strain or extensor strain. It is popular to analyze the motion of backhand stroke using kinematics and kinetics of upper extremities. In this research, the LifeMOD™ module developed from a commercially available software, ADAMS, was used for simulation. The objective is to determine the relatively fitting parameters, using compared results obtained from LifeMOD™ and Matlab. According to various researches, the parameters for each human joint set in LifeMOD™ that would play key roles for the results are stiffness, damping, and weighting. For stiffness and damping parameters, 105 N/m and 104 Ns/m respectively, is a better set for each joint. And for the weighting parameter, 10 is the best setting value for wrist joint, yet, either setting value would be applied for rest joints. In addition, the simulation model would be facile to observe the forces and moments of the joints in kinematics and kinetics for tennis backhand stroke.
- Published
- 2011
- Full Text
- View/download PDF
6. Predicting the holistic force-displacement relation of the periodontal ligament: in-vitro experiments and finite element analysis
- Author
-
Yi Hung Ho, Ting-Sheng Lin, Chih Han Chang, Yu Hsing Sung, and Yao Ning Lei
- Subjects
X-ray microtomography ,Periodontal Ligament ,Swine ,Finite Element Analysis ,Biomedical Engineering ,Dentistry ,Materials testing ,Biomechanical Phenomena ,Biomaterials ,stomatognathic system ,Materials Testing ,Periodontal fiber ,Medicine ,Animals ,Radiology, Nuclear Medicine and imaging ,Force displacement ,Mechanical Phenomena ,Micro-computed tomography ,Radiological and Ultrasound Technology ,business.industry ,Micro computed tomography ,Research ,Mechanical Processes ,General Medicine ,X-Ray Microtomography ,musculoskeletal system ,Finite element method ,business ,human activities - Abstract
Background The biomechanical property of the periodontal ligament (PDL) is important in orthodontics and prosthodontics. The objective of this study was to evaluate the feasibility of measuring the biomechanical behavior of the periodontal ligament using micro-computed tomography (micro-CT). Methods A custom-made apparatus measured the force and displacement of a porcine PDL specimen within the micro-CT environment. Synchronized computed tomography (CT) images were used to obtain the deformation and displacement of the entire specimen and to reconstruct the three-dimensional mesh model. To match the experimental results, finite element analysis was then applied to simulate the biomechanical response of the PDL. The mechanical model of the PDL was assumed as the hyperelastic material in this study. Results The volume variations of the tooth and the alveolar bone were less than 1%, which implies that tooth displacement was caused mostly by displacement of the PDL. Only translational displacement was observed with each load step because the transformation matrix acquired from the CT image registration was identical. The force-displacement curve revealed the nonlinear behavior of the PDL. There was a high correlation between the experimental displacement results and the simulation displacement results. The numerical results (based on the assumption that the PDL is the hyperelastic material) showed good agreement with the experimental results. Conclusions Nondestructive measurements by micro-CT obtained the biomechanical behavior of the PDL. Using the hyperelastic characteristic as the constitutive model can properly predict the force-displacement relation of the PDL after loading. This study provided a feasible approach for measuring the biomechanical behavior of the PDL for further dental application.
- Published
- 2014
7. Development of a rehabilitation apparatus to actuate upper extremity passive motion
- Author
-
Ching-Hua Chiu, Chung-Shun Hung, Yi-Hung Ho, and Cheng, Wei-Lin
- Subjects
rehabilitation apparatus,post-stroke patient,upper extremity passive motion - Abstract
2, 6, Maejo International Journal of Science and Technology
- Published
- 2012
- Full Text
- View/download PDF
8. Outcomes after minimally invasive lumbar decompression: a biomechanical comparison of unilateral and bilateral laminotomies.
- Author
-
Yi-Hung Ho, Yuan-Kun Tu, Chih-Kun Hsiao, and Chih-Han Chang
- Subjects
- *
SURGICAL decompression , *LUMBAR vertebrae , *LAMINECTOMY , *ALTERNATIVE medicine , *SPINAL instability - Abstract
Background: The unilateral approach for bilateral decompression was developed as an alternative to laminectomy. Unilateral laminotomy has been rated technically considerably more demanding and associated with more perioperative complications than bilateral laminotomy. Several studies have indicated that bilateral laminotomy are associated with a substantial benefit in most outcome parameters and thus constituted a promising treatment alternative. However, no complete kinematic data and relative biomechanical analysis for evaluating spinal instability treated with unilateral and bilateral laminotomy are available. Therefore, the purpose of this study was to compare the stability of various decompression methods. Methods: Ten porcine lumbar spines were biomechanically evaluated regarding their strain and range of motion, and the results were compared following unilateral or bilateral laminotomies and laminectomy. The experimental protocol included flexion and extension in the following procedures: intact, unilateral or bilateral laminotomies (L2-L5), and full laminectomy (L2-L5). The spinal segment kinematics was captured using a motion tracking system, and the strain was measured using a strain gauge. Results: No significant differences were observed during flexion and extension between the unilateral and bilateral laminotomies, whereas laminectomy yielded statistically significant findings. Regarding strain, significant differences were observed between the laminectomy and other groups. These results suggest that laminotomy entails higher spinal stability than laminectomy, with no significant differences between bilateral and unilateral laminotomies. Conclusions: The laminectomy group exhibited more instability, including the index of the range of motion and strain. However, bilateral laminotomy seems to have led to stability similar to that of unilateral laminotomy according to our short-term follow-up. In addition, performing bilateral laminotomies is easier for surgeons than adopting a unilateral approach for bilateral decompression. The results provide recommendations for surgeons regarding final decision making. Future studies conducting long-term evaluation are required. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
9. Predicting the holistic force-displacement relation of the periodontal ligament: in-vitro experiments and finite element analysis.
- Author
-
Chih-Han Chang, Yao-Ning Lei, Yi-Hung Ho, Yu-Hsing Sung, and Ting-Sheng Lin
- Abstract
Background: The biomechanical property of the periodontal ligament (PDL) is important in orthodontics and prosthodontics. The objective of this study was to evaluate the feasibility of measuring the biomechanical behavior of the periodontal ligament using micro-computed tomography (micro-CT). Methods: A custom-made apparatus measured the force and displacement of a porcine PDL specimen within the micro-CT environment. Synchronized computed tomography (CT) images were used to obtain the deformation and displacement of the entire specimen and to reconstruct the three-dimensional mesh model. To match the experimental results, finite element analysis was then applied to simulate the biomechanical response of the PDL. The mechanical model of the PDL was assumed as the hyperelastic material in this study. Results: The volume variations of the tooth and the alveolar bone were less than 1%, which implies that tooth displacement was caused mostly by displacement of the PDL. Only translational displacement was observed with each load step because the transformation matrix acquired from the CT image registration was identical. The force-displacement curve revealed the nonlinear behavior of the PDL. There was a high correlation between the experimental displacement results and the simulation displacement results. The numerical results (based on the assumption that the PDL is the hyperelastic material) showed good agreement with the experimental results. Conclusions: Nondestructive measurements by micro-CT obtained the biomechanical behavior of the PDL. Using the hyperelastic characteristic as the constitutive model can properly predict the force-displacement relation of the PDL after loading. This study provided a feasible approach for measuring the biomechanical behavior of the PDL for further dental application. [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF
10. Outcomes after minimally invasive lumbar decompression: a biomechanical comparison of unilateral and bilateral laminotomies
- Author
-
Yi Hung Ho, Chih Han Chang, Yuan Kun Tu, and Chih Kun Hsiao
- Subjects
medicine.medical_specialty ,Decompression ,Spinal stenosis ,Swine ,medicine.medical_treatment ,Lumbar vertebrae ,Laminotomy ,Lumbar ,Rheumatology ,medicine ,Animals ,Orthopedics and Sports Medicine ,Range of Motion, Articular ,Lumbar Vertebrae ,business.industry ,Laminectomy ,medicine.disease ,Decompression, Surgical ,Surgery ,Biomechanical Phenomena ,medicine.anatomical_structure ,Anesthesia ,Orthopedic surgery ,Range of motion ,business ,Research Article - Abstract
Background The unilateral approach for bilateral decompression was developed as an alternative to laminectomy. Unilateral laminotomy has been rated technically considerably more demanding and associated with more perioperative complications than bilateral laminotomy. Several studies have indicated that bilateral laminotomy are associated with a substantial benefit in most outcome parameters and thus constituted a promising treatment alternative. However, no complete kinematic data and relative biomechanical analysis for evaluating spinal instability treated with unilateral and bilateral laminotomy are available. Therefore, the purpose of this study was to compare the stability of various decompression methods. Methods Ten porcine lumbar spines were biomechanically evaluated regarding their strain and range of motion, and the results were compared following unilateral or bilateral laminotomies and laminectomy. The experimental protocol included flexion and extension in the following procedures: intact, unilateral or bilateral laminotomies (L2–L5), and full laminectomy (L2–L5). The spinal segment kinematics was captured using a motion tracking system, and the strain was measured using a strain gauge. Results No significant differences were observed during flexion and extension between the unilateral and bilateral laminotomies, whereas laminectomy yielded statistically significant findings. Regarding strain, significant differences were observed between the laminectomy and other groups. These results suggest that laminotomy entails higher spinal stability than laminectomy, with no significant differences between bilateral and unilateral laminotomies. Conclusions The laminectomy group exhibited more instability, including the index of the range of motion and strain. However, bilateral laminotomy seems to have led to stability similar to that of unilateral laminotomy according to our short-term follow-up. In addition, performing bilateral laminotomies is easier for surgeons than adopting a unilateral approach for bilateral decompression. The results provide recommendations for surgeons regarding final decision making. Future studies conducting long-term evaluation are required.
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.