1. The Behavior of Post-installed Rebar Connectors in Steel Frame Retrofitted Concrete Structures Under Combined Shear and Tension
- Author
-
Rong Zeng, En-He Bao, Xia Yin, and Feng Fu
- Subjects
Post-installed rebar connector ,Shear performance ,Deformation ,Strength ,Equivalent shear capacity ,Equivalent tensile capacity ,Systems of building construction. Including fireproof construction, concrete construction ,TH1000-1725 - Abstract
Abstract To investigate the response of post-installed rebar connectors in steel frame retrofitted concrete structures under combined shear and tension, seven shear-and-tensile tests were conducted. The bearing capacity, stiffness, and hysteresis behavior of the connectors were investigated during the tests. Both Monotonic and cyclic load regimes were applied in the loading process. The results show that with the increase of the loading angle, the deformation capacity, the yield force, ultimate tensile force, and tensile stiffness of the specimen decrease, while the maximum shear force and shear stiffness of the specimen increase. The bearing capacity, stiffness, and energy dissipation performance of the specimen under a monotonic load is greater than that under the coupled shear-and-pull load. The bearing capacity, stiffness, hysteresis curve, and failure status of the specimens are not affected by different loading regimes. At the end, the design formula of anchor bolt for this type of connectors from the design code of China, United States, and Japan were compared. Formulas to calculate the shear strength under combined shear and tension is developed.
- Published
- 2024
- Full Text
- View/download PDF