1. Polymer-Free Biolimus-Eluting Stents or Polymer-Based Zotarolimus-Eluting Stents for Coronary Bifurcation Lesions
- Author
-
Mauro Chiarito, Federico Landra, Arnaldo Poli, Guglielmo Gallone, Vincenzo Infantino, Grzegorz Smolka, Davide Capodanno, Andrea Rognoni, Franco Fabbiocchi, Fabrizio D'Ascenzo, Alfonso Ielasi, Alaide Chieffo, Gennaro Sardella, Maurizio D'Urbano, Giacomo Boccuzzi, Gaetano M. De Ferrari, Massimo Mancone, Fabrizio Tomai, Giulio G. Stefanini, Arturo Giordano, Maurizio Di Biasi, Carlo Briguori, Maurizio Tespili, and Javier Escaned
- Subjects
Male ,medicine.medical_specialty ,Acute coronary syndrome ,Polymers ,medicine.medical_treatment ,Coronary Artery Disease ,030204 cardiovascular system & hematology ,Prosthesis Design ,Coronary artery disease ,03 medical and health sciences ,Percutaneous Coronary Intervention ,0302 clinical medicine ,Internal medicine ,medicine ,Humans ,Zotarolimus ,cardiovascular diseases ,030212 general & internal medicine ,Myocardial infarction ,Sirolimus ,business.industry ,Infant ,Percutaneous coronary intervention ,Stent ,Drug-Eluting Stents ,General Medicine ,medicine.disease ,Treatment Outcome ,Conventional PCI ,Cardiology ,Female ,Stents ,Cardiology and Cardiovascular Medicine ,business ,Mace ,medicine.drug - Abstract
Background A polymer-free biolimus-eluting stent (PF-BES) and a zotarolimus-eluting stent (ZES) recently showed similar clinical profiles and appear to be competing options in specific clinical settings of patients undergoing percutaneous coronary intervention (PCI). Whether they perform similarly also in complex procedural settings as coronary bifurcation lesions remains unaddressed. Methods All consecutive patients undergoing coronary bifurcation PCI with PF-BES or the new iteration of the ZES from three large multicenter real-world registries were included. The primary outcome was major adverse cardiovascular events (MACE), a composite of all-cause death, myocardial infarction (MI), target lesion revascularization (TLR) and stent thrombosis (ST). Multiple analyses to adjust for baseline differences were carried out including propensity-score matching, propensity-score stratification and inverse-probability-weighting. Outcomes are reported according to Cox proportional hazard models censored at 400-day follow-up. Results 1169 patients treated with PF-BES (n = 440) or ZES (n = 729) on the main branch of a coronary bifurcation lesion were included (mean age 69 ± 11 years, 75.4% male, 53.8% acute coronary syndrome at presentation, 26.6% left main bifurcation, median dual antiplatelet therapy duration 12 [range 12–12] months). MACE, all-cause death, TLR and ST tended towards non-statistically higher rates with the PF-BES as compared to the ZES. Higher MI and target vessel revascularization occurrence was observed with PF-BES. Conclusions In this large contemporary cohort of patients undergoing coronary bifurcation PCI, the occurrence of MACE was non-statistically different with the use of PF-BES and ZES devices. However, differences favoring the ZES device that may entail clinical relevance were observed. Further studies are needed to confirm these findings and explore whether they remain valid when a short dual antiplatelet therapy is adopted.
- Published
- 2022