37 results on '"Van Dun B"'
Search Results
2. CR-lipped bearing is an adequate functional solution to patients with perioperative excessive laxity in cruciate retaining total knee arthroplasty
- Author
-
Kalaai, S., van Dun, B., Boonen, B., van Haaren, E.H., and Schotanus, M.G.M.
- Published
- 2021
- Full Text
- View/download PDF
3. Click-Evoked Auditory Brainstem Responses in an Australian Sea Lion (Neophoca cinerea)
- Author
-
Lucke, Klaus, Van Dun, B., Gardner-Berry, K., Carter, L., Martin, K., Rogers, T., Tripovich, J., Lucke, Klaus, Van Dun, B., Gardner-Berry, K., Carter, L., Martin, K., Rogers, T., and Tripovich, J.
- Abstract
This otariid species, endemic to Australia, is listed as vulnerable under the Australian Environmental Protection and Biodiversity Conservation Act 1999 (Australian Government, 1999) and as endangered by the International Union for Conservation of Nature (IUCN) (Goldsworthy & Gales, 2015). Breeding colonies of the Australian sea lion can only be found on the south and west coasts of Australia, and numbers are declining. Mother-pup recognition in large breeding colonies is mediated primarily through acoustic cues. Any auditory impairment of a breeding sea lion could have knock-on effects in terms of nursing and, ultimately, breeding success. While by-catch in gill-net and trap fisheries is suspected to be the main threat (Goldsworthy & Gales, 2008), effects induced by excessive exposure to anthropogenic underwater sound (such as seismic exploration, underwater explosions, and pile driving for port construction; see Wyatt, 2008) might also cause changes in the distribution or abundance of this species.
- Published
- 2016
4. Analysis of alertness status of subjects undergoing the cortical auditory evoked potential hearing test
- Author
-
Al-Ani, A, Van Dun, B, Dillon, H, and Rabie, A
- Subjects
Artificial Intelligence & Image Processing - Abstract
In this paper, we analyze the EEG rhythms of subjects undergoing the cortical auditory evoked potential (CAEP) hearing test. Investigation of the importance of the different EEG rhythms in terms of their capability in differentiating between the different alertness states when considering 64 channel EEG montage is conducted. This is followed by considering subsets that contain 2, 3, 4 as well as all 5 EEG rhythms. Finally, a feature subset selection method based on differential evolution (DE) that has particularly been proposed to deal with multi-channel signals is used to search for the best subset of EEG rhythms for the various channels. © 2012 Springer-Verlag.
- Published
- 2012
5. Kennisbundeling covergisting
- Author
-
Kool, A., de Boer, H.C., van Dooren, H.J.C., Timmerman, M., van Dun, B., and Tijmensen, M.
- Subjects
Research ,Life Science ,Research Institute for Animal Husbandry ,Praktijkonderzoek Veehouderij ,Onderzoek - Published
- 2005
6. Detection of alertness states using electroencephalogram and cortical auditory evoked potential responses
- Author
-
Rabie, A, Al-Ani, A, Van Dun, B, Dillon, H, Rabie, A, Al-Ani, A, Van Dun, B, and Dillon, H
- Abstract
In this paper, we focus on identifying the alertness state of subjects undergoing the cortical auditory evoked potential (CAEP) hearing test. A supervised classification approach is adopted, where subjects were advised to indicate their alertness states in specified time instances. Two sets of features are considered here to represent the recorded data. The first is based on the wavelet transform of the background EEG, while the second is obtained from the peaks of the CAEP responses. The rational behind using the second feature set is to evaluate the relationship between CAEP responses and alertness levels. Obtained results suggest that the CAEP-based features are very comparable, in terms of classification accuracy, to the well-established wavelet-based features of EEG signals (79% compared to 80%). The findings of this paper will contribute towards a better understanding of CAEP responses at the different alertness states. © 2013 IEEE.
- Published
- 2013
7. A Procedural Framework for Auditory Steady-State Response Detection
- Author
-
Van Dun, B., primary, Rombouts, G., additional, Wouters, J., additional, and Moonen, M., additional
- Published
- 2009
- Full Text
- View/download PDF
8. Improving Auditory Steady-State Response Detection Using Independent Component Analysis on Multichannel EEG Data
- Author
-
Van Dun, B., primary, Wouters, J., additional, and Moonen, M., additional
- Published
- 2007
- Full Text
- View/download PDF
9. The influence of the detection paradigm in recording auditory steady-state responses.
- Author
-
Luts H, Van Dun B, Alaerts J, and Wouters J
- Published
- 2008
- Full Text
- View/download PDF
10. Multi-Channel Wiener Filtering Based Auditory Steady-State Response Detection.
- Author
-
Van Dun, B., Wouters, J., and Moonen, M.
- Published
- 2007
- Full Text
- View/download PDF
11. Acoustic change complex for assessing speech discrimination in normal-hearing and hearing-impaired infants.
- Author
-
Ching TYC, Zhang VW, Ibrahim R, Bardy F, Rance G, Van Dun B, Sharma M, Chisari D, and Dillon H
- Subjects
- Humans, Infant, Evoked Potentials, Hearing Tests, Hearing, Acoustic Stimulation, Speech Perception physiology, Hearing Loss diagnosis, Hearing Aids
- Abstract
Objective: This study examined (1) the utility of a clinical system to record acoustic change complex (ACC, an event-related potential recorded by electroencephalography) for assessing speech discrimination in infants, and (2) the relationship between ACC and functional performance in real life., Methods: Participants included 115 infants (43 normal-hearing, 72 hearing-impaired), aged 3-12 months. ACCs were recorded using [szs], [uiu], and a spectral rippled noise high-pass filtered at 2 kHz as stimuli. Assessments were conducted at age 3-6 months and at 7-12 months. Functional performance was evaluated using a parent-report questionnaire, and correlations with ACC were examined., Results: The rates of onset and ACC responses of normal-hearing infants were not significantly different from those of aided infants with mild or moderate hearing loss but were significantly higher than those with severe loss. On average, response rates measured at 3-6 months were not significantly different from those at 7-12 months. Higher rates of ACC responses were significantly associated with better functional performance., Conclusions: ACCs demonstrated auditory capacity for discrimination in infants by 3-6 months. This capacity was positively related to real-life functional performance., Significance: ACCs can be used to evaluate the effectiveness of amplification and monitor development in aided hearing-impaired infants., (Copyright © 2023 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
12. Automated cortical auditory response detection strategy.
- Author
-
Bardy F, Van Dun B, Seeto M, and Dillon H
- Subjects
- Acoustic Stimulation, Adult, Evoked Potentials, Auditory, Hearing Tests, Humans, Noise adverse effects, Auditory Cortex, Deafness, Hearing Loss
- Abstract
Objective: This study describes a new automated strategy to determine the detection status of an electrophysiological response. Design: Response, noise and signal-to-noise ratio of the cortical auditory evoked potential (CAEP) were characterised. Detection rules were defined: when to start testing, when to conduct subsequent statistical tests using residual noise as an objective criterion, and when to stop testing. Study sample: Simulations were run to determine optimal parameters on a large combined CAEP data set collected in 45 normal-hearing adults and 17 adults with hearing loss. Results: The proposed strategy to detect CAEPs is fully automated. The first statistical test is conducted when the residual noise level is equal to or smaller than 5.1 µV. The succeeding Hotelling's T
2 statistical tests are conducted using pre-defined residual noise levels criteria ranging from 5.1 to 1.2 µV. A rule was introduced allowing to stop testing before the maximum number of recorded epochs is reached, depending on a minimum p -value criterion. Conclusion: The proposed framework can be applied to systems which involves detection of electrophysiological responses in biological systems containing background noise. The proposed detection algorithm which optimise sensitivity, specificity, and recording time has the potential to be used in clinical setting.- Published
- 2020
- Full Text
- View/download PDF
13. Is cortical automatic threshold estimation a feasible alternative for hearing threshold estimation with adults with dementia living in aged care?
- Author
-
Bott A, Hickson L, Meyer C, Bardy F, Van Dun B, and Pachana NA
- Subjects
- Adult, Aged, Audiometry, Pure-Tone, Auditory Threshold, Cross-Sectional Studies, Humans, Dementia diagnosis, Hearing
- Abstract
Objective: This study explored the feasibility of cortical automatic threshold estimation (CATE), a fully automated late auditory evoked potential (AEP) test, as an alternative to pure-tone audiometry for hearing threshold estimation for adults with dementia living in aged care. Design: A single group cross-sectional study was conducted. Participants' dementia severity was determined through the Clinical Dementia Rating scale. Hearing thresholds were obtained for four audiometric frequencies in at least one ear by using both pure-tone audiometry and CATE. Study sample: Sixteen participants enrolled in the study, of which 14 completed at least one of the hearing tests. Twelve ears, from six participants, were included in the final correlation analysis. Results: Pearson correlation coefficients were significant between CATE and pure-tone audiometry for all frequencies: r
2 = 0.52 ( p = 0.008) for 500 Hz, r2 = 0.79 ( p = 0.0001) for 1000 Hz, r2 = 0.71 ( p = 0.0005) for 2000 Hz, and r2 = 0.92 ( p < 0.0001) for 4000 Hz. Cortical thresholds were within 10 dB of behavioural thresholds for all four frequencies. Conclusions: Findings are encouraging for the feasibility of CATE as an alternative diagnostic test to pure-tone audiometry for adults living with dementia in aged care.- Published
- 2020
- Full Text
- View/download PDF
14. Recording Obligatory Cortical Auditory Evoked Potentials in Infants: Quantitative Information on Feasibility and Parent Acceptability.
- Author
-
Munro KJ, Purdy SC, Uus K, Visram A, Ward R, Bruce IA, Marsden A, Stone MA, and Van Dun B
- Subjects
- Acoustic Stimulation, Child, Evoked Potentials, Auditory, Feasibility Studies, Humans, Infant, Infant, Newborn, Parents, Speech, Speech Perception
- Abstract
Objectives: With the advent of newborn hearing screening and early intervention, there is a growing interest in using supra-threshold obligatory cortical auditory evoked potentials (CAEPs) to complement established pediatric clinical test procedures. The aim of this study was to assess the feasibility, and parent acceptability, of recording infant CAEPs., Design: Typically developing infants (n = 104) who had passed newborn hearing screening and whose parents expressed no hearing concerns were recruited. Testing was not possible in 6 infants, leaving 98, age range 5 to 39 weeks (mean age = 21.9, SD = 9.4). Three short duration speech-like stimuli (/m/, /g/, /t/) were presented at 65 dB SPL via a loudspeaker at 0° azimuth. Three criteria were used to assess clinical feasibility: (i) median test duration <30 min, (ii) >90% completion rate in a single test session, and (iii) >90% response detection for each stimulus. We also recorded response amplitude, latency, and CAEP signal to noise ratio. Response amplitudes and residual noise levels were compared for Fpz (n = 56) and Cz (n = 42) noninverting electrode locations. Parental acceptability was based on an 8-item questionnaire (7-point scale, 1 being best). In addition, we explored the patient experience in semistructured telephone interviews with seven families., Results: The median time taken to complete 2 runs for 3 stimuli, including preparation, was 27 min (range 17 to 59 min). Of the 104 infants, 98 (94%) were in an appropriate behavioral state for testing. A further 7 became restless during testing and their results were classified as "inconclusive." In the remaining 91 infants, CAEPs were detected in every case with normal bilateral tympanograms. Detection of CAEPs in response to /m/, /g/, and /t/ in these individuals was 86%, 100%, and 92%, respectively. Residual noise levels and CAEP amplitudes were higher for Cz electrode recordings. Mean scores on the acceptability questionnaire ranged from 1.1 to 2.6. Analysis of interviews indicated that parents found CAEP testing to be a positive experience and recognized the benefit of having an assessment procedure that uses conversational level speech stimuli., Conclusions: Test duration, completion rates, and response detection rates met (or were close to) our feasibility targets, and parent acceptability was high. CAEPs have the potential to supplement existing practice in 3- to 9-month olds.
- Published
- 2020
- Full Text
- View/download PDF
15. Clinicians' views of using cortical auditory evoked potentials (CAEP) in the permanent childhood hearing impairment patient pathway.
- Author
-
Mehta K, Mahon M, Van Dun B, Marriage J, and Vickers D
- Subjects
- Adult, Attitude of Health Personnel, Audiologists statistics & numerical data, Child, Child, Preschool, Correction of Hearing Impairment methods, Correction of Hearing Impairment psychology, Female, Hearing Tests methods, Humans, Infant, Male, Surveys and Questionnaires, Audiologists psychology, Critical Pathways statistics & numerical data, Evoked Potentials, Auditory, Hearing Loss rehabilitation, Hearing Tests psychology, Practice Patterns, Physicians' statistics & numerical data
- Abstract
Objective: To obtain clinicians' views on the use of cortical auditory evoked potentials (CAEP) in the clinical pathway. Design: A questionnaire aimed at clinicians who use the HEARLab system with the Aided Cortical Assessment (ACA) Module. Results compared for Australians (where HEARLab produced) to other countries. Sample: The questionnaire was completed by 49 clinicians; 33 from Australia and 13 clinicians outside of Australia and 3 clinicians, destination unknown. Results: The findings of this research demonstrated that clinicians using CAEPs found them valuable for clinical practice. CAEPs were used to verify or modify hearing aid fittings and were used for counselling parents to reinforce the need for hearing aids. With the use of speech token as the stimulus clinicians had more relevant information to increase confidence in decision-making on paediatric hearing management. Conclusions: The main benefit from the use of CAEPs (using speech token stimuli) was for infant hearing aid fitting programmes, to facilitate earlier decisions relating to hearing aid fitting, for fine-tuning the aids and as an additional measure for cochlear implant referrals.
- Published
- 2020
- Full Text
- View/download PDF
16. Restoration of cortical symmetry and binaural function: Cortical auditory evoked responses in adult cochlear implant users with single sided deafness.
- Author
-
Wedekind A, Rajan G, Van Dun B, and Távora-Vieira D
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Hearing Tests methods, Humans, Male, Middle Aged, Auditory Cortex physiopathology, Cochlear Implants, Evoked Potentials, Auditory physiology, Hearing Loss, Unilateral physiopathology, Hearing Loss, Unilateral therapy, Sound Localization physiology, Speech Perception physiology
- Abstract
Background: Cochlear implantation for single-sided deafness (SSD) is the only treatment option with the potential to restore binaural hearing cues. Significant binaural benefit has been measured in adults by speech in noise and localisation tests, who receive a cochlear implant for SSD, however, little is known on the cortical changes that help provide this benefit. In the present study, detection of sound in the auditory cortex, speech testing and localisation was used to investigate the ability of a cochlear implant (CI) to restore auditory cortical latencies and improve binaural benefit in the adult SSD population., Methods: Twenty-nine adults with acquired single-sided deafness who received a CI in adulthood were studied. Speech perception in noise was tested using the Bamford-Kowal-Bench speech-in-noise test, localisation ability was measured using the auditory speech sounds evaluation (AδE) localisation test and cortical auditory evoked responses, comparing N1-P2 latencies recorded from the normal hearing ear and cochlear implant were used to investigate the synchrony of the cortical pathway from the CI and normal hearing ear (NHe) with binaural hearing function., Results: There was a significant improvement in speech perception in noise in all spatial configurations S0/N0 (Z = -3.066, p<0.002), S0/NHE (Z = -4.031, p<0.001), SCI/NHE (Z = -3.851, p<0.001). Localization significantly improved when tested with the cochlear implant on (p<0.001) with a shorter duration of deafness correlating to a greater improvement in localisation ability F(1:18) = 6.854; p = 0.017). There was no significant difference in N1-P2 latency recorded from the normal hearing ear and the CI., Conclusion: Cortical auditory evoked response latencies recorded from the CI and NHe showed no significant difference, indicating that the detection of sound in the auditory cortex occurred simultaneously, providing the cortex with auditory information for binaural hearing., Competing Interests: The authors have declared no competing interests exist.
- Published
- 2020
- Full Text
- View/download PDF
17. The frequency-following response as an assessment of spatial processing.
- Author
-
Graydon K, Van Dun B, Dowell R, and Rance G
- Subjects
- Acoustic Stimulation, Adolescent, Age Factors, Child, Comprehension, Cues, Female, Humans, Male, Speech Intelligibility, Noise adverse effects, Perceptual Masking, Sound Localization, Speech Perception
- Abstract
Objective: It is important to detect children with difficulties distinguishing speech-in-noise early. Prompt identification may be assisted by an evoked potential. The aims of the present study were: 1) to evaluate the frequency-following response (FFR) as a measure of binaural processing and spatial listening and, 2) to investigate the relationship between the FFR and a behavioural measure of binaural processing and spatial listening. Design: A single group, repeated measures design. The FFR was recorded in two different spatial conditions and amplitudes compared to spatial listening ability. Study Sample: Thirty-two children (aged 6.0 to 13.1 years) with a range of spatial processing abilities as measured behaviourally using the Listening in Spatialised Noise Sentences test (LiSN-S). Results: FFR waveforms were elicited using speech-like stimuli in co-located and separated conditions. A significant ( p≤ 0.005) spatial advantage effect was observed with larger amplitudes in the separated condition. No correlations were observed between FFR amplitude and LiSN-S results. Conclusions: The FFR shows promise as a measure of binaural processing and spatial listening, but could be measuring different processes to those measured by the LiSN-S.
- Published
- 2019
- Full Text
- View/download PDF
18. Effects of lifetime noise exposure on the middle-age human auditory brainstem response, tinnitus and speech-in-noise intelligibility.
- Author
-
Valderrama JT, Beach EF, Yeend I, Sharma M, Van Dun B, and Dillon H
- Subjects
- Acoustic Stimulation, Adult, Age Factors, Audiometry, Speech, Auditory Threshold, Case-Control Studies, Cochlear Diseases diagnosis, Cochlear Diseases physiopathology, Cochlear Diseases psychology, Electroencephalography, Female, Hearing, Hearing Loss, Noise-Induced diagnosis, Hearing Loss, Noise-Induced physiopathology, Hearing Loss, Noise-Induced psychology, Humans, Male, Middle Aged, Reaction Time, Time Factors, Tinnitus diagnosis, Tinnitus physiopathology, Tinnitus psychology, Cochlea physiopathology, Cochlear Diseases etiology, Evoked Potentials, Auditory, Brain Stem, Hearing Loss, Noise-Induced etiology, Noise adverse effects, Perceptual Masking, Speech Intelligibility, Speech Perception, Tinnitus etiology
- Abstract
Recent animal studies have shown that the synapses between inner hair cells and the dendrites of the spiral ganglion cells they innervate are the elements in the cochlea most vulnerable to excessive noise exposure. Particularly in rodents, several studies have concluded that exposure to high level octave-band noise for 2 h leads to an irreversible loss of around 50% of synaptic ribbons, leaving audiometric hearing thresholds unaltered. Cochlear synaptopathy following noise exposure is hypothesized to degrade the neural encoding of sounds at the subcortical level, which would help explain certain listening-in-noise difficulties reported by some subjects with otherwise 'normal' hearing. In response to this peripheral damage, increased gain of central stages of the auditory system has been observed across several species of mammals, particularly in association with tinnitus. The auditory brainstem response (ABR) wave I amplitude and waves I-V amplitude ratio have been suggested as non-invasive indicators of cochlear synaptopathy and central gain activation respectively, but the evidence for these hearing disorders in humans is inconclusive. In this study, we evaluated the influence of lifetime noise exposure (LNE) on the human ABR and on speech-in-noise intelligibility performance in a large cohort of adults aged 29 to 55. Despite large inter-subject variability, results showed a moderate, but statistically significant, negative correlation between the ABR wave I amplitude and LNE, consistent with cochlear synaptopathy. The results also showed (a) that central gain mechanisms observed in animal studies might also occur in humans, in which higher stages of the auditory pathway appear to compensate for reduced input from the cochlea; (b) that tinnitus was associated with activation of central gain mechanisms; (c) that relevant cognitive and subcortical factors influence speech-in-noise intelligibility, in particular, longer ABR waves I-V interpeak latencies were associated with poorer performance in understanding speech in noise when central gain mechanisms were active; and (d) absence of a significant relationship between LNE and tinnitus, central gain activation or speech-in-noise performance. Although this study supports the possible existence of cochlear synaptopathy in humans, the great degree of variability, the lack of uniformity in central gain activation and the significant involvement of attention in speech-in-noise performance suggests that noise-induced cochlear synaptopathy is, at most, one of several factors that play a role in humans' speech-in-noise performance., (Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
19. Remediation of spatial processing disorder (SPD).
- Author
-
Graydon K, Van Dun B, Tomlin D, Dowell R, and Rance G
- Subjects
- Auditory Perception, Child, Cues, Female, Humans, Male, Perceptual Disorders psychology, Treatment Outcome, Cognitive Remediation methods, Perceptual Disorders therapy, Spatial Processing
- Abstract
Objective: To determine the efficacy of deficit-specific remediation for spatial processing disorder, quantify effects of remediation on functional listening, and determine if remediation is maintained., Design: Participants had SPD, diagnosed using the Listening in Spatialised Noise-Sentences test. The LiSN and Learn software was provided as auditory training. Post-training, repeat LiSN-S testing was conducted. Questionnaires pre- and post-training acted as subjective measures of remediation. A late-outcome assessment established long-term effects of remediation., Study Sample: Sixteen children aged between 6;3 [years; months] and 10;0 completed between 20 and 146 training games., Results: Post-training LiSN-S improved in measures containing spatial cues (p ≤ 0.001) by 2.0 SDs (3.6 dB) for DV90, 1.8 SDs for SV90 (3.2 dB), 1.4 SDs for spatial advantage (2.9 dB) and 1.6 SDs for total advantage (3.3 dB). Improvement was also found in the DV0 condition (1.4 dB or 0.5 SDs). Post-training changes were not significant in the talker advantage measure (1.0 dB or 0.4 SDs) or the SV0 condition (0.3 dB or 0.1 SDs). The late-outcome assessment demonstrated improvement was maintained. Subjective improvement post-remediation was observed using the parent questionnaire., Conclusions: Children with SPD had improved ability to utilise spatial cues following deficit-specific remediation, with the parent questionnaire sensitive to remediation. Effects of the remediation also appear to be sustained.
- Published
- 2018
- Full Text
- View/download PDF
20. Clinically recorded cortical auditory evoked potentials from paediatric cochlear implant users fitted with electrically elicited stapedius reflex thresholds.
- Author
-
Kosaner J, Van Dun B, Yigit O, Gultekin M, and Bayguzina S
- Subjects
- Acoustic Impedance Tests, Child, Preschool, Female, Hearing Loss physiopathology, Humans, Infant, Longitudinal Studies, Male, Stapedius physiopathology, Auditory Cortex physiology, Cochlear Implantation methods, Cochlear Implants, Evoked Potentials, Auditory physiology, Hearing Loss surgery, Speech Perception physiology
- Abstract
Objectives: This study aimed to objectively evaluate access to soft sounds (55 dB SPL) in paediatric CI users, all wearing MED-EL (Innsbruck, Austria) devices who were fitted with the objective electrically elicited stapedius reflex threshold (eSRT) fitting method, to track their cortical auditory evoked potential (CAEP) presence and latency, and to compare their CAEPs to those of normal-hearing peers., Methods: Forty-five unilaterally implanted, pre-lingually deafened MED-EL CI users, aged 12-48 months, underwent CAEP testing in the clinic at regular monthly intervals post switch-on. CAEPs were recorded in response to short speech tokens /m/, /g/ and /t/ presented in the free field at 55 dB SPL. Twenty children with normal hearing (NH), similarly aged, underwent CAEP testing once., Results: The proportion of present CAEPs increased and CAEP P1 latencies reduced significantly with post-implantation duration. CAEPs were scored based on their presence and age-appropriate P1 latency. These CAEP scores increased significantly with post-implantation duration. CAEP scores were significantly worse for the /m/ speech token compared to the other two tokens. Compared to the NH group, CAEP scores were significantly smaller for all post-implantation test intervals., Conclusions: This study provides clinicians with a first step towards typical ranges of CAEP presence, latency, and derived CAEP score over the first months of MED-EL CI use. CAEPs within these typical ranges could validate intervention whereas less than optimum CAEPs could prompt clinicians to seek solutions in a timely manner. CAEPs could clinically validate whether a CI provides adequate access to soft sounds. This approach could form an alternative to behavioural soft sound access verification., (Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
21. An automatic algorithm for blink-artifact suppression based on iterative template matching: application to single channel recording of cortical auditory evoked potentials.
- Author
-
Valderrama JT, de la Torre A, and Van Dun B
- Subjects
- Adult, Electrooculography methods, Female, Humans, Male, Algorithms, Artifacts, Blinking physiology, Electroencephalography methods, Evoked Potentials, Auditory physiology
- Abstract
Objective: Artifact reduction in electroencephalogram (EEG) signals is usually necessary to carry out data analysis appropriately. Despite the large amount of denoising techniques available with a multichannel setup, there is a lack of efficient algorithms that remove (not only detect) blink-artifacts from a single channel EEG, which is of interest in many clinical and research applications. This paper describes and evaluates the iterative template matching and suppression (ITMS), a new method proposed for detecting and suppressing the artifact associated with the blink activity from a single channel EEG., Approach: The approach of ITMS consists of (a) an iterative process in which blink-events are detected and the blink-artifact waveform of the analyzed subject is estimated, (b) generation of a signal modeling the blink-artifact, and (c) suppression of this signal from the raw EEG. The performance of ITMS is compared with the multi-window summation of derivatives within a window (MSDW) technique using both synthesized and real EEG data., Main Results: Results suggest that ITMS presents an adequate performance in detecting and suppressing blink-artifacts from a single channel EEG. When applied to the analysis of cortical auditory evoked potentials (CAEPs), ITMS provides a significant quality improvement in the resulting responses, i.e. in a cohort of 30 adults, the mean correlation coefficient improved from 0.37 to 0.65 when the blink-artifacts were detected and suppressed by ITMS., Significance: ITMS is an efficient solution to the problem of denoising blink-artifacts in single-channel EEG applications, both in clinical and research fields. The proposed ITMS algorithm is stable; automatic, since it does not require human intervention; low-invasive, because the EEG segments not contaminated by blink-artifacts remain unaltered; and easy to implement, as can be observed in the Matlab script implemeting the algorithm provided as supporting material.
- Published
- 2018
- Full Text
- View/download PDF
22. Consequences of Early Conductive Hearing Loss on Long-Term Binaural Processing.
- Author
-
Graydon K, Rance G, Dowell R, and Van Dun B
- Subjects
- Adolescent, Case-Control Studies, Child, Female, Hearing Loss, Conductive etiology, Hearing Tests, Humans, Male, Signal-To-Noise Ratio, Sound Localization, Auditory Perception, Hearing Loss, Conductive physiopathology, Otitis Media complications
- Abstract
Objectives: The aim of the study was to investigate the long-term effects of early conductive hearing loss on binaural processing in school-age children., Design: One hundred and eighteen children participated in the study, 82 children with a documented history of conductive hearing loss associated with otitis media and 36 controls who had documented histories showing no evidence of otitis media or conductive hearing loss. All children were demonstrated to have normal-hearing acuity and middle ear function at the time of assessment. The Listening in Spatialized Noise Sentence (LiSN-S) task and the masking level difference (MLD) task were used as the two different measures of binaural interaction ability., Results: Children with a history of conductive hearing loss performed significantly poorer than controls on all LiSN-S conditions relying on binaural cues (DV90, p = <0.001 and SV90, p = 0.003). No significant difference was found between the groups in listening conditions without binaural cues. Fifteen children with a conductive hearing loss history (18%) showed results consistent with a spatial processing disorder. No significant difference was observed between the conductive hearing loss group and the controls on the MLD task. Furthermore, no correlations were found between LiSN-S and MLD., Conclusions: Results show a relationship between early conductive hearing loss and listening deficits that persist once hearing has returned to normal. Results also suggest that the two binaural interaction tasks (LiSN-S and MLD) may be measuring binaural processing at different levels. Findings highlight the need for a screening measure of functional listening ability in children with a history of early otitis media.
- Published
- 2017
- Full Text
- View/download PDF
23. Effects of spectral smearing on performance of the spectral ripple and spectro-temporal ripple tests.
- Author
-
Narne VK, Sharma M, Van Dun B, Bansal S, Prabhu L, and Moore BC
- Abstract
The main aim of this study was to use spectral smearing to evaluate the efficacy of a spectral ripple test (SRt) using stationary sounds and a recent variant with gliding ripples called the spectro-temporal ripple test (STRt) in measuring reduced spectral resolution. In experiment 1 the highest detectable ripple density was measured using four amounts of spectral smearing (unsmeared, mild, moderate, and severe). The thresholds worsened with increasing smearing and were similar for the SRt and the STRt across the three conditions with smearing. For unsmeared stimuli, thresholds were significantly higher (better) for the STRt than for the SRt. An amplitude fluctuation at the outputs of simulated (gammatone) auditory filters centered above 6400 Hz was identified as providing a potential detection cue for the STRt stimuli. Experiment 2 used notched noise with energy below and above the passband of the SRt and STRt stimuli to reduce confounding cues in the STRt. Thresholds were almost identical for the STRt and SRt for both unsmeared and smeared stimuli, indicating that the confounding cue for the STRt was eliminated by the notched noise. Thresholds obtained with notched noise present could be predicted reasonably accurately using an excitation-pattern model.
- Published
- 2016
- Full Text
- View/download PDF
24. Cortical Auditory-Evoked Potentials in Response to Multitone Stimuli in Hearing-Impaired Adults.
- Author
-
Bardy F, Sjahalam-King J, Van Dun B, and Dillon H
- Subjects
- Aged, Aged, 80 and over, Auditory Threshold, Deafness, Female, Humans, Male, Middle Aged, Noise, Sensitivity and Specificity, Acoustic Stimulation methods, Evoked Potentials, Auditory, Hearing Tests
- Abstract
Purpose: To determine if one-octave multitone (MT) stimuli increase the amplitude of cortical auditory-evoked potentials (CAEPs) in individuals with a hearing loss when compared to standard pure-tone (PT) stimuli and narrow-band noise (NBN)., Research Design: CAEPs were obtained from 16 hearing-impaired adults in response to PT and MT auditory stimuli centered around 0.5, 1, 2, and 4 kHz and NBN centered around 1 and 2 kHz. Hearing impairment ranged from a mild to a moderate hearing loss in both ears. Auditory stimuli were monaurally delivered through insert earphones at 10 and 20 dB above threshold. The root mean square amplitude of the CAEP and the detectability of the responses using Hotelling's T² were calculated and analyzed., Results: CAEP amplitudes elicited with MT stimuli were on average 29% larger than PT stimuli for frequencies centered around 1, 2, and 4 kHz. No significant difference was found for responses to 0.5-kHz stimuli. Significantly higher objective detection scores were found for MT when compared to PT. For the 1- and 2-kHz stimuli, the CAEP amplitudes to NBN were not significantly different to those evoked by PT but a significant difference was found between MT stimuli and both NBN and PT. The mean detection sensitivity of MT for the four frequencies was 80% at 10 dB SL and 95% at 20 dB SL, and was comparable with detection sensitivities observed in normal-hearing participants., Conclusions: Using MT stimuli when testing CAEPs in adults with hearing impairment showed larger amplitudes and a higher objective detection sensitivity compared to using traditional PT stimuli for frequencies centered around 1, 2, and 4 kHz. These findings suggest that MT stimuli are a clinically useful tool to increase the efficiency of frequency-specific CAEP testing in adults with hearing impairment., (American Academy of Audiology.)
- Published
- 2016
- Full Text
- View/download PDF
25. Clinical Experience of Using Cortical Auditory Evoked Potentials in the Treatment of Infant Hearing Loss in Australia.
- Author
-
Punch S, Van Dun B, King A, Carter L, and Pearce W
- Abstract
This article presents the clinical protocol that is currently being used within Australian Hearing for infant hearing aid evaluation using cortical auditory evoked potentials (CAEPs). CAEP testing is performed in the free field at two stimulus levels (65 dB sound pressure level [SPL], followed by 55 or 75 dB SPL) using three brief frequency-distinct speech sounds /m/, /ɡ/, and /t/, within a standard audiological appointment of up to 90 minutes. CAEP results are used to check or guide modifications of hearing aid fittings or to confirm unaided hearing capability. A retrospective review of 83 client files evaluated whether clinical practice aligned with the clinical protocol. It showed that most children could be assessed as part of their initial fitting program when they were identified as a priority for CAEP testing. Aided CAEPs were most commonly assessed within 8 weeks of the fitting. A survey of 32 pediatric audiologists provided information about their perception of cortical testing at Australian Hearing. The results indicated that clinical CAEP testing influenced audiologists' approach to rehabilitation and was well received by parents and that they were satisfied with the technique. Three case studies were selected to illustrate how CAEP testing can be used in a clinical environment. Overall, CAEP testing has been effectively integrated into the infant fitting program.
- Published
- 2016
- Full Text
- View/download PDF
26. Cortical Auditory Evoked Potentials in (Un)aided Normal-Hearing and Hearing-Impaired Adults.
- Author
-
Van Dun B, Kania A, and Dillon H
- Abstract
Cortical auditory evoked potentials (CAEPs) are influenced by the characteristics of the stimulus, including level and hearing aid gain. Previous studies have measured CAEPs aided and unaided in individuals with normal hearing. There is a significant difference between providing amplification to a person with normal hearing and a person with hearing loss. This study investigated this difference and the effects of stimulus signal-to-noise ratio (SNR) and audibility on the CAEP amplitude in a population with hearing loss. Twelve normal-hearing participants and 12 participants with a hearing loss participated in this study. Three speech sounds-/m/, /g/, and /t/-were presented in the free field. Unaided stimuli were presented at 55, 65, and 75 dB sound pressure level (SPL) and aided stimuli at 55 dB SPL with three different gains in steps of 10 dB. CAEPs were recorded and their amplitudes analyzed. Stimulus SNRs and audibility were determined. No significant effect of stimulus level or hearing aid gain was found in normal hearers. Conversely, a significant effect was found in hearing-impaired individuals. Audibility of the signal, which in some cases is determined by the signal level relative to threshold and in other cases by the SNR, is the dominant factor explaining changes in CAEP amplitude. CAEPs can potentially be used to assess the effects of hearing aid gain in hearing-impaired users.
- Published
- 2016
- Full Text
- View/download PDF
27. Bigger Is Better: Increasing Cortical Auditory Response Amplitude Via Stimulus Spectral Complexity.
- Author
-
Bardy F, Van Dun B, and Dillon H
- Subjects
- Adult, Audiometry, Pure-Tone, Electroencephalography, Female, Healthy Volunteers, Humans, Male, Young Adult, Acoustic Stimulation methods, Auditory Cortex physiology, Evoked Potentials, Auditory physiology
- Abstract
Objective: To determine the influence of auditory stimuli spectral characteristics on cortical auditory evoked potentials (CAEPs)., Design: CAEPs were obtained from 15 normal-hearing adults in response to six multitone (MT), four pure-tone (PT), and two narrowband noise stimuli. The sounds were presented at 10, 20, and 40 dB above threshold, which were estimated behaviorally beforehand. The root mean square amplitude of the CAEP and the detectability of the response were calculated and analyzed., Results: Amplitudes of the CAEPs to the MT were significantly larger compared with PT for stimuli with frequencies centered around 1, 2, and 4 kHz, whereas no significant difference was found for 0.5 kHz. The objective detection score for the MT was significantly higher compared with the PT. For the 1- and 2-kHz stimuli, the CAEP amplitudes to narrowband noise were not significantly different than those evoked by PT., Conclusion: The study supports the notion that spectral complexity, not just bandwidth, has an impact on the CAEP amplitude for stimuli with center frequency above 0.5 kHz. The implication of these findings is that the clinical test time required to estimate thresholds can potentially be decreased by using complex band-limited MT rather than conventional PT stimuli.
- Published
- 2015
- Full Text
- View/download PDF
28. Estimating Hearing Thresholds in Hearing-Impaired Adults through Objective Detection of Cortical Auditory Evoked Potentials.
- Author
-
Van Dun B, Dillon H, and Seeto M
- Subjects
- Adult, Audiometry, Cohort Studies, Decision Trees, Female, Humans, Male, Noise, Reproducibility of Results, Auditory Threshold physiology, Evoked Potentials, Auditory physiology, Hearing Loss, Sensorineural diagnosis, Hearing Loss, Sensorineural physiopathology
- Abstract
Background: Hearing threshold estimation based on cortical auditory evoked potentials (CAEPs) has been applied for some decades. However, available research is scarce evaluating the accuracy of this technique with an automated paradigm for the objective detection of CAEPs., Purpose: To determine the difference between behavioral and CAEP thresholds detected using an objective paradigm based on the Hotelling's T² statistic. To propose a decision tree to choose the next stimulus level in a sample of hearing-impaired adults. This knowledge potentially could increase the efficiency of clinical hearing threshold testing., Research Design: Correlational cohort study. Thresholds obtained behaviorally were compared with thresholds obtained through cortical testing., Study Sample: Thirty-four adults with hearing loss participated in this study., Data Collection and Analysis: For each audiometric frequency and each ear, behavioral thresholds were collected with both pure-tone and 40-msec tone-burst stimuli. Then, corresponding cortical hearing thresholds were determined. An objective cortical-response detection algorithm based on the Hotelling's T² statistic was applied to determine response presence. A decision tree was used to select the next stimulus level. In total, 241 behavioral-cortical threshold pairs were available for analysis. The differences between CAEP and behavioral thresholds (and their standard deviations [SDs]) were determined for each audiometric frequency. Cortical amplitudes and electroencephalogram noise levels were extracted. The practical applicability of the decision tree was evaluated and compared to a Hughson-Westlake paradigm., Results: It was shown that, when collapsed over all audiometric frequencies, behavioral pure-tone thresholds were on average 10 dB lower than 40-msec cortical tone-burst thresholds, with an SD of 10 dB. Four percent of CAEP thresholds, all obtained from just three individual participants, were more than 30 dB higher than their behavioral counterparts. The use of a decision tree instead of a Hughson-Westlake procedure to obtain a CAEP threshold did not seem to reduce test time, but there was significantly less variation in the number of CAEP trials needed to determine a threshold., Conclusions: Behavioral hearing thresholds in hearing-impaired adults can be determined with an acceptable degree of accuracy (mean threshold correction and SD of both 10 dB) using an objective statistical cortical-response detection algorithm in combination with a decision tree to determine the test levels., (American Academy of Audiology.)
- Published
- 2015
- Full Text
- View/download PDF
29. Least-squares (LS) deconvolution of a series of overlapping cortical auditory evoked potentials: a simulation and experimental study.
- Author
-
Bardy F, Van Dun B, Dillon H, and Cowan R
- Subjects
- Acoustic Stimulation, Adult, Algorithms, Computer Simulation, Electroencephalography, Evoked Potentials, Auditory, Brain Stem physiology, Female, Humans, Least-Squares Analysis, Male, Signal-To-Noise Ratio, Auditory Cortex physiology, Evoked Potentials, Auditory physiology
- Abstract
Objective: To evaluate the viability of disentangling a series of overlapping 'cortical auditory evoked potentials' (CAEPs) elicited by different stimuli using least-squares (LS) deconvolution, and to assess the adaptation of CAEPs for different stimulus onset-asynchronies (SOAs)., Approach: Optimal aperiodic stimulus sequences were designed by controlling the condition number of matrices associated with the LS deconvolution technique. First, theoretical considerations of LS deconvolution were assessed in simulations in which multiple artificial overlapping responses were recovered. Second, biological CAEPs were recorded in response to continuously repeated stimulus trains containing six different tone-bursts with frequencies 8, 4, 2, 1, 0.5, 0.25 kHz separated by SOAs jittered around 150 (120-185), 250 (220-285) and 650 (620-685) ms. The control condition had a fixed SOA of 1175 ms. In a second condition, using the same SOAs, trains of six stimuli were separated by a silence gap of 1600 ms. Twenty-four adults with normal hearing (<20 dB HL) were assessed., Main Results: Results showed disentangling of a series of overlapping responses using LS deconvolution on simulated waveforms as well as on real EEG data. The use of rapid presentation and LS deconvolution did not however, allow the recovered CAEPs to have a higher signal-to-noise ratio than for slowly presented stimuli. The LS deconvolution technique enables the analysis of a series of overlapping responses in EEG., Significance: LS deconvolution is a useful technique for the study of adaptation mechanisms of CAEPs for closely spaced stimuli whose characteristics change from stimulus to stimulus. High-rate presentation is necessary to develop an understanding of how the auditory system encodes natural speech or other intrinsically high-rate stimuli.
- Published
- 2014
- Full Text
- View/download PDF
30. Deconvolution of overlapping cortical auditory evoked potentials recorded using short stimulus onset-asynchrony ranges.
- Author
-
Bardy F, Van Dun B, Dillon H, and McMahon CM
- Subjects
- Acoustic Stimulation methods, Adult, Electroencephalography, Female, Humans, Male, Middle Aged, Young Adult, Auditory Cortex physiology, Evoked Potentials, Auditory physiology
- Abstract
Objective: The first aim of this study is to validate the theoretical framework of least-squares (LS) deconvolution on experimental data. The second is to investigate the waveform morphology of the cortical auditory evoked potential (CAEP) for five stimulus onset-asynchronies (SOAs) and effects of alternating stimulus frequency in normally hearing adults., Methods: Eleven adults (19-55 years) with normal hearing were investigated using tone-burst stimuli of 500 and 2000 Hz with SOAs jittered around 150, 250, 450, and 850 ms in a paired-interval paradigm with fixed or alternating stimulus frequency., Results: The LS deconvolution technique disentangled the overlapping responses, which then provided the following insights. The CAEP amplitude reached a minimum value for SOAs jittered around 450 ms, in contrast with significantly larger amplitudes for SOAs jittered around 150 and 850 ms. Despite this, longer latencies of N1 and P2 consistently occurred for decreasing SOAs. Alternating stimulus frequency significantly increased the amplitude of the CAEP response and decreased latencies for SOAs jittered around 150 ms. Effects of SOAs and alternating stimuli on CAEP amplitude can be modelled using a quantitative model of latent inhibition., Conclusions: LS deconvolution allows correction for cortical response overlap. The amplitude of the CAEP is sensitive to SOA and stimulus frequency alternation., Significance: CAEPs are emerging as an important tool in the objective evaluation of hearing aid and cochlear implant fittings. Responses to closely spaced stimuli provide objective information about integration and inhibition mechanisms in the auditory cortex., (Copyright © 2013 International Federation of Clinical Neurophysiology. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
31. Least-squares deconvolution of evoked potentials and sequence optimization for multiple stimuli under low-jitter conditions.
- Author
-
Bardy F, Dillon H, and Van Dun B
- Subjects
- Computer Simulation, Electroencephalography, Humans, Noise, Physical Stimulation, Brain physiology, Evoked Potentials physiology, Models, Theoretical
- Abstract
Objective: Rapid presentation of stimuli in an evoked response paradigm can lead to overlap of multiple responses and consequently difficulties interpreting waveform morphology. This paper presents a deconvolution method allowing overlapping multiple responses to be disentangled., Methods: The deconvolution technique uses a least-squared error approach. A methodology is proposed to optimize the stimulus sequence associated with the deconvolution technique under low-jitter conditions. It controls the condition number of the matrices involved in recovering the responses. Simulations were performed using the proposed deconvolution technique., Results: Multiple overlapping responses can be recovered perfectly in noiseless conditions. In the presence of noise, the amount of error introduced by the technique can be controlled a priori by the condition number of the matrix associated with the used stimulus sequence. The simulation results indicate the need for a minimum amount of jitter, as well as a sufficient number of overlap combinations to obtain optimum results. An aperiodic model is recommended to improve reconstruction., Conclusions: We propose a deconvolution technique allowing multiple overlapping responses to be extracted and a method of choosing the stimulus sequence optimal for response recovery., Significance: This technique may allow audiologists, psychologists, and electrophysiologists to optimize their experimental designs involving rapidly presented stimuli, and to recover evoked overlapping responses., (Copyright © 2013 International Federation of Clinical Neurophysiology. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
32. Cortical auditory-evoked potentials (CAEPs) in adults in response to filtered speech stimuli.
- Author
-
Carter L, Dillon H, Seymour J, Seeto M, and Van Dun B
- Subjects
- Acoustic Stimulation methods, Adult, Age Factors, Aged, Aged, 80 and over, Child, Female, Hearing Loss, Sensorineural diagnosis, Hearing Loss, Sensorineural rehabilitation, Humans, Infant, Male, Middle Aged, Persons With Hearing Impairments psychology, Persons With Hearing Impairments rehabilitation, Prosthesis Fitting methods, Regression Analysis, Sensitivity and Specificity, Speech Acoustics, Audiometry methods, Auditory Threshold physiology, Evoked Potentials, Auditory, Brain Stem physiology, Hearing Aids, Hearing Loss, Sensorineural physiopathology, Speech Perception physiology
- Abstract
Background: Previous studies have demonstrated that cortical auditory-evoked potentials (CAEPs) can be reliably elicited in response to speech stimuli in listeners wearing hearing aids. It is unclear, however, how close to the aided behavioral threshold (i.e., at what behavioral sensation level) a sound must be before a cortical response can reliably be detected., Purpose: The purpose of this study was to systematically examine the relationship between CAEP detection and the audibility of speech sounds (as measured behaviorally), when the listener is wearing a hearing aid fitted to prescriptive targets. A secondary aim was to investigate whether CAEP detection is affected by varying the frequency emphasis of stimuli, so as to simulate variations to the prescribed gain-frequency response of a hearing aid. The results have direct implications for the evaluation of hearing aid fittings in nonresponsive adult clients, and indirect implications for the evaluation of hearing aid fittings in infants., Research Design: Participants wore hearing aids while listening to speech sounds presented in a sound field. Aided thresholds were measured, and cortical responses evoked, under a range of stimulus conditions. The presence or absence of CAEPs was determined by an automated statistic., Study Sample: Participants were adults (6 females and 4 males). Participants had sensorineural hearing loss ranging from mild to severe-profound in degree., Data Collection and Analysis: Participants' own hearing aids were replaced with a test hearing aid, with linear processing, during assessments. Pure-tone thresholds and hearing aid gain measurements were obtained, and a theoretical prediction of speech stimulus audibility for each participant (similar to those used for audibility predictions in infant hearing aid fittings) was calculated. Three speech stimuli, (/m/, /t/, and /g/) were presented aided (monaurally, nontest ear occluded), free field, under three conditions (+4 dB/octave, -4 dB/octave, and without filtering), at levels of 40, 50, and 60 dB SPL (measured for the unfiltered condition). Behavioral thresholds were obtained, and CAEP recordings were made using these stimuli. The interaction of hearing loss, presentation levels, and filtering conditions resulted in a range of CAEP test behavioral sensation levels (SLs), from -25 to +40 dB., Results: Statistically significant CAEPs (p < .05) were obtained for virtually every presentation where the behavioral sensation level was >10 dB, and for only 5% of occasions when the sensation level was negative. In these ("false-positive") cases, the greatest (negative) sensation level at which a CAEP was judged to be present was -6 dB SL., Conclusions: CAEPs are a sensitive tool for directly evaluating the audibility of speech sounds, at least for adult listeners. CAEP evaluation was found to be more accurate than audibility predictions, based on threshold and hearing aid response measures., (American Academy of Audiology.)
- Published
- 2013
- Full Text
- View/download PDF
33. The relationship between cortical auditory evoked potential (CAEP) detection and estimated audibility in infants with sensorineural hearing loss.
- Author
-
Chang HW, Dillon H, Carter L, van Dun B, and Young ST
- Subjects
- Acoustic Stimulation, Auditory Threshold, Correction of Hearing Impairment, Female, Hearing Aids, Hearing Loss, Sensorineural physiopathology, Hearing Loss, Sensorineural psychology, Hearing Loss, Sensorineural rehabilitation, Humans, Infant, Male, Models, Statistical, New South Wales, Persons With Hearing Impairments psychology, Persons With Hearing Impairments rehabilitation, Predictive Value of Tests, Psychoacoustics, Sound Spectrography, Speech Acoustics, Audiometry, Speech, Cerebral Cortex physiopathology, Electroencephalography, Evoked Potentials, Auditory, Hearing Loss, Sensorineural diagnosis, Speech Perception
- Abstract
Objective: To determine the effectiveness of objective statistical detection in CAEP testing to evaluate audibility in young infants with sensorineural hearing loss., Design: CAEP recordings to speech-based stimuli were made at three presentation levels (55, 65, or 75 dB SPL) when a group of hearing-impaired infants were either aided or unaided. Later-obtained behavioral audiograms were used as the gold standard against which to evaluate the accuracy of the automatic detection of the presence/absence of CAEP responses., Study Sample: Participants were 18 infants with confirmed sensorineural hearing loss., Results: Higher sensation levels led to a greater number of present CAEP responses being detected. More CAEP waveforms were detected in the aided condition than in the unaided condition., Conclusion: Our results suggest that the presence/absence of CAEP responses defined by the automatic statistical criterion was effective in showing whether increased sensation levels provided by amplification were sufficient to reach the cortex. This was clearly apparent from the significant increase in cortical detections when comparing unaided with aided testing.
- Published
- 2012
- Full Text
- View/download PDF
34. Sensitivity of cortical auditory evoked potential detection for hearing-impaired infants in response to short speech sounds.
- Author
-
Van Dun B, Carter L, and Dillon H
- Abstract
Cortical auditory evoked potentials (CAEPs) are an emerging tool for hearing aid fitting evaluation in young children who cannot provide reliable behavioral feedback. It is therefore useful to determine the relationship between the sensation level of speech sounds and the detection sensitivity of CAEPs, which is the ratio between the number of detections and the sum of detections and non-detections. Twenty-five sensorineurally hearing impaired infants with an age range of 8 to 30 months were tested once, 18 aided and 7 unaided. First, behavioral thresholds of speech stimuli /m/, /g/, and /t/ were determined using visual reinforcement orientation audiometry. Afterwards, the same speech stimuli were presented at 55, 65, and 75 dB sound pressure level, and CAEPs were recorded. An automatic statistical detection paradigm was used for CAEP detection. For sensation levels above 0, 10, and 20 dB respectively, detection sensitivities were equal to 72±10, 75±10, and 78±12%. In 79% of the cases, automatic detection P-values became smaller when the sensation level was increased by 10 dB. The results of this study suggest that the presence or absence of CAEPs can provide some indication of the audibility of a speech sound for infants with sensorineural hearing loss. The detection of a CAEP might provide confidence, to a degree commensurate with the detection probability, that the infant is detecting that sound at the level presented. When testing infants where the audibility of speech sounds has not been established behaviorally, the lack of a cortical response indicates the possibility, but by no means a certainty, that the sensation level is 10 dB or less.
- Published
- 2012
- Full Text
- View/download PDF
35. Latencies of auditory steady-state responses recorded in early infancy.
- Author
-
Alaerts J, Luts H, Van Dun B, Desloovere C, and Wouters J
- Subjects
- Adult, Age Factors, Auditory Threshold physiology, Child, Preschool, Deafness congenital, Deafness physiopathology, Female, Gestational Age, Humans, Infant, Infant, Newborn, Infant, Premature, Diseases physiopathology, Male, Otoacoustic Emissions, Spontaneous, Reference Values, Sound Spectrography, Young Adult, Audiometry, Evoked Response methods, Deafness diagnosis, Evoked Potentials, Auditory physiology, Infant, Premature, Diseases diagnosis, Neonatal Screening, Reaction Time physiology
- Abstract
Multiple-stimulus auditory steady-state responses (ASSRs) were assessed in 111 ears of 70 infants between -4 and 19 weeks of age at risk for hearing loss. ASSR thresholds obtained in infants with normal hearing (n = 69 ears) were compared with normal adult ASSR thresholds (n = 32 ears), and the linear relation between ASSR thresholds and behavioral thresholds (BHTs) was investigated in normal-hearing and hearing-impaired infants (n = 79 ears). Furthermore, latency estimates of significant responses to stimuli of 50 dB SPL were compared between the normal-hearing infants (n = 171 data points) and adults (n = 124 data points) and developmental changes in latency were evaluated within the infant group. Normal ASSR thresholds were on average 12 dB higher in infants compared with adults. Correlations between ASSR thresholds and BHTs were 0.75, 0.87, 0.87 and 0.79 for 500, 1000, 2000 and 4000 Hz, respectively. There was a significant effect of carrier frequency on ASSR latency, with higher carrier frequencies evoking shorter latencies in both infants and adults. Mean latencies in adults were 24.3 +/- 1.5, 22.3 +/- 1.1, 19.4 +/- 1.0 and 18.0 +/- 1.1 ms for 500, 1000, 2000 and 4000 Hz, respectively. Depending on the data fit of the infant latency estimates, mean latencies were 1.0 ms shorter or 9.5 ms longer in infants compared with adults. In infants, latencies were on average 2.0 ms longer in the youngest infant group (< or =0 weeks) relative to the oldest infant group (3-8 weeks). These age-related trends, together with other arguments, point to longer latencies in infants compared with adults. The results of this study are valuable as a clinical reference for interpreting ASSR results obtained in high-risk infants within their first months of life and indicate that developmental changes occur regarding ASSR latency., (Copyright 2009 S. Karger AG, Basel.)
- Published
- 2010
- Full Text
- View/download PDF
36. Optimal electrode selection for multi-channel electroencephalogram based detection of auditory steady-state responses.
- Author
-
Van Dun B, Wouters J, and Moonen M
- Subjects
- Acoustic Stimulation, Adult, Algorithms, Artifacts, Auditory Threshold physiology, Evoked Potentials, Auditory, Female, Humans, Male, Models, Theoretical, Young Adult, Auditory Cortex physiology, Auditory Perception physiology, Brain Stem physiology, Electrodes, Electroencephalography instrumentation, Electroencephalography methods
- Abstract
Auditory steady-state responses (ASSRs) are used for hearing threshold estimation at audiometric frequencies. Hearing impaired newborns, in particular, benefit from this technique as it allows for a more precise diagnosis than traditional techniques, and a hearing aid can be better fitted at an early age. However, measurement duration of current single-channel techniques is still too long for clinical widespread use. This paper evaluates the practical performance of a multi-channel electroencephalogram (EEG) processing strategy based on a detection theory approach. A minimum electrode set is determined for ASSRs with frequencies between 80 and 110 Hz using eight-channel EEG measurements of ten normal-hearing adults. This set provides a near-optimal hearing threshold estimate for all subjects and improves response detection significantly for EEG data with numerous artifacts. Multi-channel processing does not significantly improve response detection for EEG data with few artifacts. In this case, best response detection is obtained when noise-weighted averaging is applied on single-channel data. The same test setup (eight channels, ten normal-hearing subjects) is also used to determine a minimum electrode setup for 10-Hz ASSRs. This configuration allows to record near-optimal signal-to-noise ratios for 80% of subjects.
- Published
- 2009
- Full Text
- View/download PDF
37. A flexible research platform for multi-channel auditory steady-state response measurements.
- Author
-
Van Dun B, Verstraeten S, Alaerts J, Luts H, Moonen M, and Wouters J
- Subjects
- Acoustic Stimulation, Adult, Audiometry, Evoked Response instrumentation, Auditory Cortex physiology, Auditory Threshold physiology, Electroencephalography instrumentation, Electronics instrumentation, Functional Laterality physiology, Humans, Reference Values, Signal Processing, Computer-Assisted instrumentation, Software trends, Audiometry, Evoked Response methods, Auditory Perception physiology, Electroencephalography methods, Electronics methods, Evoked Potentials, Auditory physiology, Software standards
- Abstract
The possibilities of currently commercially available auditory steady-state response (ASSR) devices are mostly limited to avoid unintentional misuse and to guarantuee patient safety as such. Some setups, e.g. do not allow the application of high intensities or the use of own stimuli. Moreover, most devices generally only allow data collection using maximal two EEG channels. The freedom to modify and extend the accompagnying software and hardware is very restricted or inexistent. As a result, these devices are not suited for research and several clinically diagnostic purposes. In this paper, a research platform for multi-channel ASSR measurements is presented, referred to as SOMA (setup ORL for multi-channel ASSR). The setup allows multi-channel measurements and the use of own stimuli. It can be easily extended to facilitate new measurement protocols and real-time signal processing. The mobile setup is based on an inexpensive multi-channel RME soundcard and software is written in C++. Both hardware and software of the setup are described. An evaluation study with nine normal-hearing subjects shows no significant performance differences between a reference and the proposed platform. SOMA presents a flexible and modularly extensible mobile high-end multi-channel ASSR test platform.
- Published
- 2008
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.