21 results on '"Ubben T"'
Search Results
2. Schlaganfallprophylaxe bei der Transkatheteraortenklappenimplantation (TAVI): Aktueller Stand
- Author
-
Ubben, T., Schmidt, T., Kuck, K.-H., and Frerker, C.
- Published
- 2017
- Full Text
- View/download PDF
3. Impact of intervention strategies after failed Mitraclip therapy on mid-term outcome
- Author
-
Alessandrini, H, primary, Geidel, S, additional, Wohlmuth, P, additional, Meincke, F, additional, Hakmi, S, additional, Gosau, N, additional, Ubben, T, additional, Kuck, K.H, additional, and Willems, S, additional
- Published
- 2020
- Full Text
- View/download PDF
4. Examining the Emotional and Physical Health Impact in Users of Open-Source Automated Insulin Delivery and Sources of Support: Qualitative Analysis of Patient Narratives.
- Author
-
Cleal B, Chen Y, Wäldchen M, Ballhausen H, Cooper D, O'Donnell S, Knoll C, Krug N, Raile K, Ubben T, Tappe A, Lewis D, Willaing I, Skinner T, and Braune K
- Subjects
- Humans, Female, Male, Middle Aged, Adult, Emotions, Quality of Life psychology, Insulin Infusion Systems, Narration, Qualitative Research, Diabetes Mellitus psychology, Diabetes Mellitus drug therapy, Aged, Insulin administration & dosage, Insulin therapeutic use
- Abstract
Background: Although commercially developed automated insulin delivery (AID) systems have recently been approved and become available in a limited number of countries, they are not universally available, accessible, or affordable. Therefore, open-source AID systems, cocreated by an online community of people with diabetes and their families behind the hashtag #WeAreNotWaiting, have become increasingly popular., Objective: This study focused on examining the lived experiences, physical and emotional health implications of people with diabetes following the initiation of open-source AID systems, their perceived challenges, and their sources of support, which have not been explored in the existing literature., Methods: We collected data from 383 participants across 29 countries through 2 sets of open-ended questions in a web-based survey on their experience of building and using open-source AID systems. Narratives were thematically analyzed, and a coding framework was identified through iterative alignment., Results: Participants consistently reported improvements in glycemia, physical health, sleep quality, emotional impact on everyday life, and quality of life. Knowledge of open-source AID systems was largely obtained through the #WeAreNotWaiting community, which was also the primary source of practical and emotional support. The acquisition of the components to build an open-source AID system and the technical setup were sometimes problematic., Conclusions: The #WeAreNotWaiting movement represents a primary example of how informed and connected patients proactively address their unmet needs, provide peer support to each other, and obtain results through impactful, user-driven solutions. Alongside providing evidence on the safety and efficacy of open-source AID systems, this qualitative analysis helps in understanding how patients' experiences and benefits range from psychosocial improvements to a reduction in the burden of managing diabetes., International Registered Report Identifier (irrid): RR2-10.2196/15368., (©Bryan Cleal, Yanbing Chen, Mandy Wäldchen, Hanne Ballhausen, Drew Cooper, Shane O'Donnell, Christine Knoll, Niklas Krug, Klemens Raile, Tebbe Ubben, Adrian Tappe, Dana Lewis, Ingrid Willaing, Timothy Skinner, Katarina Braune. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 06.01.2025.)
- Published
- 2025
- Full Text
- View/download PDF
5. German Experience with a Novel Balloon-Expandable Heart Valve Prosthesis for Transcatheter Aortic Valve Implantation-Outcomes of the MYLAND (MYvaL germAN stuDy) Study.
- Author
-
Ubben T, Tigges E, Kim WK, Holzamer A, Breitenbach I, Sodian R, Rothe J, Hochholzer W, Hakmi S, and Neumann FJ
- Abstract
Background: The primary objective of this study was to evaluate the initial experience in Germany with the Meril Myval™ (MM) transcatheter heart valve (THV) system for the treatment of severe symptomatic aortic valve stenosis. The MM THV is a novel balloon-expandable valve with an expanded sizing matrix. Contemporary patients undergoing TAVI with the established Edwards Sapien™ (ES) THV served as the comparator group. Methods : Between 1st March and 31 August 2020 a total of 134 patients (33% female, 80.1 ± 6.7 years; EuroScore II 4.7 ± 4.8) underwent TAVI with an MM (95% transfemoral) for severe aortic stenosis at six German tertiary care centers. Results: Correct positioning of the THV was achieved in 98.5% (n = 132). Mean aortic gradients (MPG) were reduced from 42 ± 14 mmHg to 11 ± 5 mmHg. Mild postprocedural paravalvular leak (PVL) was observed in 62% (n = 82) patients, whereas only one patient had more than mild PVL. New permanent pacemaker implantation (PPI) was indicated in 15 patients (11%). Major vascular complications occurred in 6.7% (n = 9) patients. The in-hospital combined incidence of all-cause death and stroke was 4.5% (n = 6). In the comparator group that included 268 patients, the 30-day incidences of PPI, major vascular complications, and the composite of all-cause death and stroke were 16%, 1.9%, and 7.1%, respectively; MPGs were reduced from 44 ± 15 mmHg to 12.8 ± 4.6 mmHg and the more than mild PVL occurred in 0.7%. Conclusions: The MM is a promising novel THV system, with performance comparable to the established ES THVs. These findings await confirmation by ongoing randomized trials.
- Published
- 2024
- Full Text
- View/download PDF
6. Association of pulmonary hypertension with the outcome in patients undergoing edge-to-edge mitral valve repair.
- Author
-
Ubben T, Frerker C, Fujita B, Rosenkranz S, Pfister R, Baldus S, Alessandrini H, Kuck KH, Willems S, Eitel I, and Schmidt T
- Subjects
- Humans, Female, Male, Retrospective Studies, Aged, Treatment Outcome, Mitral Valve diagnostic imaging, Mitral Valve physiopathology, Mitral Valve surgery, Pulmonary Wedge Pressure physiology, Middle Aged, Risk Factors, Hemodynamics physiology, Hypertension, Pulmonary physiopathology, Hypertension, Pulmonary mortality, Hypertension, Pulmonary diagnosis, Mitral Valve Insufficiency surgery, Mitral Valve Insufficiency physiopathology, Mitral Valve Insufficiency mortality, Mitral Valve Insufficiency diagnosis, Mitral Valve Insufficiency complications, Cardiac Catheterization methods
- Abstract
Objectives: The association of pulmonary hypertension (PH) with the outcome after mitral transcatheter edge-to-edge repair (M-TEER) focusing on the new ESC/ERS guidelines definition for PH., Background: PH is frequently found in patients with mitral regurgitation and is associated with lower survival rates. Recent studies were based on echocardiographic parameters, but results based on invasive haemodynamics differentiating distinct types of PH using the new definition for PH are missing., Methods: 449 consecutive M-TEER-treated patients from December 2009 to February 2015 were included in this retrospective analysis. All patients were stratified by the distinct types of PH (no PH, precapillary PH, isolated postcapillary PH, combined post-PH and precapillary PH) according to the definitions of the ESC/ERS guidelines for the diagnosis of PH from 2015 (meanPA cut-off <25 mm Hg, pulmonary capillary wedge pressure (PCWP) cut-off ≤15 mm Hg, diastolic pulmonary gradient cut-off ≥7 mm Hg or pulmonary vascular resistance (PVR) >3 WU) and 2022 (meanPA cut-off ≤20 mm Hg, PCWP cut-off ≤15 mm Hg, PVR cut-off ≥3 WU)., Results: Patients with any type of PH (2015: meanPA cut-off 25 mm Hg; 2022: meanPA cut-off >20 mm Hg) showed a higher risk of death after M-TEER compared with patients with no PH (2015: HR 1.61 (95% CI 1.25 to 2.07); p<0.001 and 2022: HR 2.09 (95% CI 1.54 to 2.83); p<0.001). Based on the new PH definition, each PH subgroup showed a lower survival after M-TEER compared with patients with no PH. Echocardiographic estimated systolic PAP showed a correlation with invasively measured mean pulmonary artery pressure (mPAP) (r=0.29, p<0.001) and systolic pulmonary arterial pressure (r=0.34,p<0.001). Cox-regression analysis showed higher invasive diastolic, systolic and mean pulmonary pressures were associated with higher all-cause mortality (p<0.001). In addition, invasive measured higher right atrial pressure, lower pulmonary arterial compliance, higher PVR and higher wedge pressure were identified as predictors of all-cause mortality after M-TEER., Conclusions: The new PH definition discriminates PH groups and mortality better than the old definition. The lower threshold of mPAP of 20mmHg improved prognostication in this cohort of patients., Competing Interests: Competing interests: TU, BF, K-HK and SR declare the full disclosure of any relationship with industry. IE received lecture honoraria and research grants by Abbott and lecture honoraria by Edwards. HA received travel support by Abbott. T. Schmidt, S. Willems, CF received lecture honoraria and travel support from Abbott Vascular and Edwards Lifesciences. RP received lecture honoraria from Abbott Vascular and Edwards and is a consultant for Edwards. SB received lecture honoraria and research grants from Edwards and Abbott., (© Author(s) (or their employer(s)) 2024. No commercial re-use. See rights and permissions. Published by BMJ.)
- Published
- 2024
- Full Text
- View/download PDF
7. Open-source Web Portal for Managing Self-reported Data and Real-world Data Donation in Diabetes Research: Platform Feasibility Study.
- Author
-
Cooper D, Ubben T, Knoll C, Ballhausen H, O'Donnell S, Braune K, and Lewis D
- Abstract
Background: People with diabetes and their support networks have developed open-source automated insulin delivery systems to help manage their diabetes therapy, as well as to improve their quality of life and glycemic outcomes. Under the hashtag #WeAreNotWaiting, a wealth of knowledge and real-world data have been generated by users of these systems but have been left largely untapped by research; opportunities for such multimodal studies remain open., Objective: We aimed to evaluate the feasibility of several aspects of open-source automated insulin delivery systems including challenges related to data management and security across multiple disparate web-based platforms and challenges related to implementing follow-up studies., Methods: We developed a mixed methods study to collect questionnaire responses and anonymized diabetes data donated by participants-which included adults and children with diabetes and their partners or caregivers recruited through multiple diabetes online communities. We managed both front-end participant interactions and back-end data management with our web portal (called the Gateway). Participant questionnaire data from electronic data capture (REDCap) and personal device data aggregation (Open Humans) platforms were pseudonymously and securely linked and stored within a custom-built database that used both open-source and commercial software. Participants were later given the option to include their health care providers in the study to validate their questionnaire responses; the database architecture was designed specifically with this kind of extensibility in mind., Results: Of 1052 visitors to the study landing page, 930 participated and completed at least one questionnaire. After the implementation of health care professional validation of self-reported clinical outcomes to the study, an additional 164 individuals visited the landing page, with 142 completing at least one questionnaire. Of the optional study elements, 7 participant-health care professional dyads participated in the survey, and 97 participants who completed the survey donated their anonymized medical device data., Conclusions: The platform was accessible to participants while maintaining compliance with data regulations. The Gateway formalized a system of automated data matching between multiple data sets, which was a major benefit to researchers. Scalability of the platform was demonstrated with the later addition of self-reported data validation. This study demonstrated the feasibility of custom software solutions in addressing complex study designs. The Gateway portal code has been made available open-source and can be leveraged by other research groups., (©Drew Cooper, Tebbe Ubben, Christine Knoll, Hanne Ballhausen, Shane O'Donnell, Katarina Braune, Dana Lewis. Originally published in JMIR Diabetes (https://diabetes.jmir.org), 31.03.2022.)
- Published
- 2022
- Full Text
- View/download PDF
8. Comprehensive echocardiographic prediction of postprocedural transmitral pressure gradient following transcatheter mitral valve repair.
- Author
-
Alessandrini H, Wohlmuth P, Meincke F, Hakmi S, Ubben T, Bohnen S, Wißt T, Kuck KH, Willems S, and Tigges E
- Subjects
- Cardiac Catheterization adverse effects, Echocardiography, Female, Humans, Male, Mitral Valve diagnostic imaging, Mitral Valve surgery, Predictive Value of Tests, Retrospective Studies, Treatment Outcome, Heart Valve Prosthesis Implantation adverse effects, Mitral Valve Insufficiency diagnostic imaging, Mitral Valve Insufficiency etiology, Mitral Valve Insufficiency surgery
- Abstract
Iatrogenic mitral stenosis following transcatheter mitral valve repair (TMVR) for relevant mitral regurgitation (MR) is a potential adverse side-effect, known to affect long-term outcome. However, only few determinants of an elevated mean transmitral pressure gradient (TMPG) have been described thus far. We sought to develop an integrative model for the prediction of TMPG following MitraClip (MC) therapy. From 01/2013 to 03/2017, a total of 175 consecutive patients were successfully (MR ≤ 2 + at discharge) treated with a MitraClip implantation at our centre. Of these, a total of 148 patients (54% male, 77.0 ± 6.0 years, 58% with secondary MR) had complete echocardiographic data sets comprising pre- and postinterventional two- and three-dimensional transthoracic (TTE) and transoesophageal (TOE) echocardiograms. Comprehensive studies of predefined parameters were performed. An expert-based prediction model including preprocedural variables (annular ellipticity, mitral valve commissure-to-commissure diameter, preprocedural transmitral pressure gradient and MR aetiology) was set up and validated with a total of 200 bootstrap samples. A nomogram was developed to predict the postprocedural TMPG based on selected echocardiographic variables. Introduction of nomogram-based guiding of MC therapy could help identify patients at risk for postprocedural mitral stenosis, have an influence on preprocedural patient selection and intraprocedural decision making., (© 2021. The Author(s), under exclusive licence to Springer Nature B.V.)
- Published
- 2021
- Full Text
- View/download PDF
9. Benefits of routine prophylactic femoral access during transvenous lead extraction.
- Author
-
Chung DU, Müller L, Ubben T, Yildirim Y, Petersen J, Sinning C, Castro L, Demal TJ, Kaiser L, Gosau N, Reichenspurner H, Willems S, Pecha S, and Hakmi S
- Subjects
- Aged, Female, Femoral Vein, Follow-Up Studies, Humans, Male, Retrospective Studies, Risk Factors, Treatment Outcome, Defibrillators, Implantable, Device Removal adverse effects, Pacemaker, Artificial, Postoperative Complications prevention & control
- Abstract
Background: The number of patients requiring lead extraction has been increasing in recent years. Despite significant advances in operator experience and technique, unexpected complications may occur. Prophylactic placement of femoral sheaths allows for immediate endovascular access for emergency procedures and may shorten response time in the event of complications., Objective: The purpose of this study was to assess the benefits of routine prophylactic femoral access in patients undergoing transvenous lead extraction (TLE) and to evaluate the methods, frequency, and efficacy of the emergency measures used in those patients., Methods: We conducted a retrospective analysis of patients who underwent TLE from January 2012 to February 2019. The data were analyzed with regard to procedural complications and deployment of emergency measures via femoral access., Results: Two hundred eighty-five patients (mean age 65.3 ± 15.5 years) were included in the study. Median lead dwell time was 84 months (interquartile range 58-144). Overall complication rate was 4.2% (n = 12), with 1.8% major complications (n = 5). Clinical success rate was 97.2%. Procedure-related mortality was 1.1% (n = 3). Femoral sheaths were actively engaged in 9.1% (n = 26) of cases. Deployment of snares was the most common intervention (n = 10), followed by prophylactic (n = 6) or emergency placement (n = 1) of occlusion balloons, temporary pacing (n = 3), venous angioplasty (n = 3), diagnostic venography (n = 3), and extracorporeal membrane oxygenation (n = 1). We did not observe any femoral vascular complications due to prophylactic sheath placement., Conclusion: Routine prophylactic placement of femoral sheaths shortens response time and quickly establishes control in the event of various complications that may occur during TLE procedures., (Copyright © 2021 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
10. Permanent Pacemaker Implantation Following Valve-in-Valve Transcatheter Aortic Valve Replacement: VIVID Registry.
- Author
-
Alperi A, Rodés-Cabau J, Simonato M, Tchetche D, Charbonnier G, Ribeiro HB, Latib A, Montorfano M, Barbanti M, Bleiziffer S, Redfors B, Abdel-Wahab M, Allali A, Bruschi G, Napodano M, Agrifoglio M, Petronio AS, Giannini C, Chan A, Kornowski R, Pravda NS, Adam M, Iadanza A, Noble S, Chatfield A, Erlebach M, Kempfert J, Ubben T, Wijeysundera H, Seiffert M, Pilgrim T, Kim WK, Testa L, Hildick-Smith D, Nerla R, Fiorina C, Brinkmann C, Conzelmann L, Champagnac D, Saia F, Nissen H, Amrane H, Whisenant B, Shamekhi J, Søndergaard L, Webb JG, and Dvir D
- Subjects
- Aged, Aged, 80 and over, Female, Humans, Male, Prosthesis Implantation, Registries, Pacemaker, Artificial, Transcatheter Aortic Valve Replacement methods
- Abstract
Background: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs)., Objectives: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures., Methods: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs., Results: A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups)., Conclusions: In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up., Competing Interests: Funding Support and Author Disclosures Dr. Alperi was supported by a grant from the Fundación Alfonso Martin Escudero (Madrid, Spain). Dr. Rodés-Cabau holds the Research Chair “Fondation Famille Jacques Larivière” for the Development of Structural Heart Disease Interventions, and has received institutional research grants from Edwards Lifesciences and Medtronic. Dr. Montorfano is a proctor for Edwards Lifesciences, Abbott, and Boston Scientific. Dr. Adam has received personal fees from Edwards Lifesciences and Boston Scientific; and has received grants and personal fees from Medtronic during the conduct of the study. Dr. Noble has received institutional research grants from Abbott Vascular, Edwards Lifesciences, and Medtronic; and is a proctor for Medtronic. Dr. Erlebach has received fees from Medtronic. Dr. Kempfert has received fees from Medtronic, Edwards Lifesciences, and Abbott. Dr. Pilgrim has received institutional research grants from Biotronik, Boston Scientific, and Edwards Lifesciences; has received speaker fees from Biotronik and Boston Scientific; has received consultancy fees from HighLife SAS (CEC); and has performed proctoring for Medtronic and Boston Scientific. Dr. Kim has received personal fees from, performed proctoring for, and has served on advisory boards for Abbott Vascular, Boston Scientific, Edwards Lifesciences, Meril, Medtronic, and Shockwave Med. Dr. Hildick-Smith has served as a proctor and advisor for Edwards Lifesciences, Boston Scientific, and Medtronic. Dr. Dvir has provided consulting for Edwards Lifesciences, Medtronic, and Abbott. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose., (Copyright © 2021 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
11. Clinical impact of intervention strategies after failed transcatheter mitral valve repair.
- Author
-
Alessandrini H, Dreher A, Harr C, Wohlmuth P, Meincke F, Hakmi S, Ubben T, Kuck KH, Hassan K, Willems S, Schmoeckel M, and Geidel S
- Subjects
- Cardiac Catheterization adverse effects, Humans, Mitral Valve diagnostic imaging, Mitral Valve surgery, Treatment Outcome, Cardiac Surgical Procedures, Heart Valve Prosthesis Implantation adverse effects, Mitral Valve Insufficiency diagnostic imaging, Mitral Valve Insufficiency surgery
- Abstract
Aims: Failure of transcatheter mitral valve repair (fTMVR) therapy has a decisive prognostic influence, and complex retreatment is of higher risk. The aim of this analysis was to evaluate the survival outcome following percutaneous procedures and surgery after unsuccessful TMVR interventions for different aetiologies., Methods and Results: Of 824 consecutive patients who had been treated with the MitraClip device at our institution, between September 2009 and May 2019, 63 (7.6%) symptomatic patients with therapy failure and persistent or recurrent mitral regurgitation (MR) underwent reinterventions. An outcome analysis for primary (PMR) and secondary mitral regurgitation (SMR) and subsequent percutaneous versus surgical treatment was carried out. MitraClip reinterventions were performed in 36 patients (57.1%; n=26 SMR, n=10 PMR), while 27 (42.9%; n=13 SMR, n=14 PMR) underwent open heart surgery. Surgical patients with PMR showed lower mortality than patients with SMR (p<0.0001) and ReClip patients with PMR (p=0.073). Atrial fibrillation (HR 2.915, 95% CI: [1.311, 6.480]), prior open heart surgery (2.820 [1.215, 6.544]) and chronic obstructive pulmonary disease (2.506 [1.099, 5.714]) increased the risk of death. The level of post-interventional MR had no relevant impact on survival., Conclusions: We conclude that, after SMR and failed TMVR, reclipping is an appropriate treatment option for symptomatic patients. For PMR patients, surgery must be favoured over a reclipping procedure. However, patients with atrial fibrillation, prior open heart surgery and chronic obstructive pulmonary disease are at risk of reduced survival after reinterventions.
- Published
- 2021
- Full Text
- View/download PDF
12. Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement: Comprehensive Midterm Evaluation of Valve-in-Valve and Valve-in-Ring Implantation From the VIVID Registry.
- Author
-
Simonato M, Whisenant B, Ribeiro HB, Webb JG, Kornowski R, Guerrero M, Wijeysundera H, Søndergaard L, De Backer O, Villablanca P, Rihal C, Eleid M, Kempfert J, Unbehaun A, Erlebach M, Casselman F, Adam M, Montorfano M, Ancona M, Saia F, Ubben T, Meincke F, Napodano M, Codner P, Schofer J, Pelletier M, Cheung A, Shuvy M, Palma JH, Gaia DF, Duncan A, Hildick-Smith D, Veulemans V, Sinning JM, Arbel Y, Testa L, de Weger A, Eltchaninoff H, Hemery T, Landes U, Tchetche D, Dumonteil N, Rodés-Cabau J, Kim WK, Spargias K, Kourkoveli P, Ben-Yehuda O, Teles RC, Barbanti M, Fiorina C, Thukkani A, Mackensen GB, Jones N, Presbitero P, Petronio AS, Allali A, Champagnac D, Bleiziffer S, Rudolph T, Iadanza A, Salizzoni S, Agrifoglio M, Nombela-Franco L, Bonaros N, Kass M, Bruschi G, Amabile N, Chhatriwalla A, Messina A, Hirji SA, Andreas M, Welsh R, Schoels W, Hellig F, Windecker S, Stortecky S, Maisano F, Stone GW, and Dvir D
- Subjects
- Aged, Aged, 80 and over, Female, Follow-Up Studies, Heart Valve Diseases diagnostic imaging, Heart Valve Prosthesis trends, Heart Valve Prosthesis Implantation methods, Heart Valve Prosthesis Implantation trends, Humans, Internationality, Male, Middle Aged, Mitral Valve diagnostic imaging, Reoperation trends, Retrospective Studies, Transcatheter Aortic Valve Replacement trends, Heart Valve Diseases surgery, Heart Valve Prosthesis standards, Mitral Valve surgery, Registries, Reoperation standards, Transcatheter Aortic Valve Replacement standards
- Abstract
Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR., Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate., Results: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR ( P <0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients ( P =0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P <0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P =0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P =0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P =0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P <0.001) were both independently associated with repeat mitral valve replacement., Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.
- Published
- 2021
- Full Text
- View/download PDF
13. Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism.
- Author
-
Braune K, Wäldchen M, Raile K, Hahn S, Ubben T, Römer S, Hoeber D, Reibel NJ, Launspach M, Blankenstein O, and Bührer C
- Subjects
- Female, Humans, Infant, Newborn, Male, Blood Glucose metabolism, Blood Glucose Self-Monitoring methods, Congenital Hyperinsulinism diagnosis, Intensive Care Units, Neonatal standards
- Abstract
Background: Use of real-time continuous glucose monitoring (rtCGM) systems has been shown to be a low-pain, safe, and effective method of preventing hypoglycemia and hyperglycemia in people with diabetes of various age groups. Evidence on rtCGM use in infants and in patients with conditions other than diabetes remains limited., Objective: This case study describes the off-label use of rtCGM and the use of an open-source app for glucose monitoring in a newborn with prolonged hypoglycemia secondary to transient congenital hyperinsulinism during the perinatal period., Methods: The Dexcom G6 rtCGM system (Dexcom, Inc) was introduced at 39 hours of age. Capillary blood glucose checks were performed regularly. In order to benefit from customizable alert settings and detect hypoglycemic episodes, the open-source rtCGM app xDrip+ was introduced at 9 days of age., Results: Time in range (45-180 mg/dL) for interstitial glucose remained consistently above 90%, whereas time in hypoglycemia (<45 mg/dL) decreased. Mean glucose was maintained above 70 mg/dL at 72 hours of life and thereafter. Daily sensor glucose profiles showed cyclic fluctuations that were less pronounced over time., Conclusions: While off-label use of medication is both common practice and a necessity in newborn infants, there are few examples of off-label uses of medical devices, rtCGM being a notable exception. Real-time information allowed us to better understand glycemic patterns and to improve the quality of glycemic control accordingly. Severe hypoglycemia was prevented, and measurement of serum levels of insulin and further lab diagnostics were performed much faster, while the patient's individual burden caused by invasive procedures was reduced. Greater customizability of threshold and alert settings would be beneficial for user groups with glycemic instability other than people with diabetes, and for hospitalized newborn infants in particular. Further research in the field of personal and off-label rtCGM use, efficacy studies evaluating the accuracy of low glucose readings, and studies on the differences between algorithms in translating raw sensor data, as well as customization of commercially available rtCGM systems, is needed., (©Katarina Braune, Mandy Wäldchen, Klemens Raile, Sigrid Hahn, Tebbe Ubben, Susanne Römer, Daniela Hoeber, Nora Johanna Reibel, Michael Launspach, Oliver Blankenstein, Christoph Bührer. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 04.12.2020.)
- Published
- 2020
- Full Text
- View/download PDF
14. Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves.
- Author
-
Bleiziffer S, Simonato M, Webb JG, Rodés-Cabau J, Pibarot P, Kornowski R, Windecker S, Erlebach M, Duncan A, Seiffert M, Unbehaun A, Frerker C, Conzelmann L, Wijeysundera H, Kim WK, Montorfano M, Latib A, Tchetche D, Allali A, Abdel-Wahab M, Orvin K, Stortecky S, Nissen H, Holzamer A, Urena M, Testa L, Agrifoglio M, Whisenant B, Sathananthan J, Napodano M, Landi A, Fiorina C, Zittermann A, Veulemans V, Sinning JM, Saia F, Brecker S, Presbitero P, De Backer O, Søndergaard L, Bruschi G, Franco LN, Petronio AS, Barbanti M, Cerillo A, Spargias K, Schofer J, Cohen M, Muñoz-Garcia A, Finkelstein A, Adam M, Serra V, Teles RC, Champagnac D, Iadanza A, Chodor P, Eggebrecht H, Welsh R, Caixeta A, Salizzoni S, Dager A, Auffret V, Cheema A, Ubben T, Ancona M, Rudolph T, Gummert J, Tseng E, Noble S, Bunc M, Roberts D, Kass M, Gupta A, Leon MB, and Dvir D
- Subjects
- Aged, Aged, 80 and over, Aortic Valve surgery, Female, Humans, Male, Prosthesis Design, Prosthesis Failure, Treatment Outcome, Aortic Valve Stenosis surgery, Bioprosthesis, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Transcatheter Aortic Valve Replacement
- Abstract
Aims: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV., Methods and Results: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]., Conclusions: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV., (Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2020. For permissions, please email: journals.permissions@oup.com.)
- Published
- 2020
- Full Text
- View/download PDF
15. Evidence on User-Led Innovation in Diabetes Technology (The OPEN Project): Protocol for a Mixed Methods Study.
- Author
-
O'Donnell S, Lewis D, Marchante Fernández M, Wäldchen M, Cleal B, Skinner T, Raile K, Tappe A, Ubben T, Willaing I, Hauck B, Wolf S, and Braune K
- Abstract
Background: Digital innovations in health care have traditionally followed a top-down pathway, with manufacturers leading the design and production of technology-enabled solutions and those living with chronic conditions involved only as passive recipients of the end product. However, user-driven open-source initiatives in health care are becoming increasingly popular. An example is the growing movement of people with diabetes, who create their own "Do-It-Yourself Artificial Pancreas Systems" (DIYAPS)., Objective: The overall aim of this study is to establish the empirical evidence base for the clinical effectiveness and quality-of-life benefits of DIYAPS and identify the challenges and possible solutions to enable their wider diffusion., Methods: A research program comprising 5 work packages will examine the outcomes and potential for scaling up DIYAPS solutions. Quantitative and qualitative methodologies will be used to examine clinical and self-reported outcome measures of DIYAPS users. The majority of members of the research team live with type 1 diabetes and are active DIYAPS users, making Outcomes of Patients' Evidence With Novel, Do-It-Yourself Artificial Pancreas Technology (OPEN) a unique, user-driven research project., Results: This project has received funding from the European Commission's Horizon 2020 Research and Innovation Program, under the Marie Skłodowska-Curie Action Research and Innovation Staff Exchange. Researchers with both academic and nonacademic backgrounds have been recruited to formulate research questions, drive the research process, and disseminate ongoing findings back to the DIYAPS community and other stakeholders., Conclusions: The OPEN project is unique in that it is a truly patient- and user-led research project, which brings together an international, interdisciplinary, and intersectoral research group, comprising health care professionals, technical developers, biomedical and social scientists, the majority of whom are also living with diabetes. Thus, it directly addresses the core research and user needs of the DIYAPS movement. As a new model of cooperation, it will highlight how researchers in academia, industry, and the patient community can create patient-centric innovation and reduce disease burden together., International Registered Report Identifier (irrid): PRR1-10.2196/15368., (©Shane O'Donnell, Dana Lewis, María Marchante Fernández, Mandy Wäldchen, Bryan Cleal, Timothy Skinner, Klemens Raile, Adrian Tappe, Tebbe Ubben, Ingrid Willaing, Bastian Hauck, Saskia Wolf, Katarina Braune. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 19.11.2019.)
- Published
- 2019
- Full Text
- View/download PDF
16. Successful balloon valvuloplasty of rheumatic mitral valve stenosis in a pregnant patient without fluoroscopy: a case report.
- Author
-
Ubben T, Frerker C, Kuck KH, and Schmidt T
- Abstract
Introduction: Rheumatic mitral stenosis (MS) is the most common rheumatic heart disease that complicates pregnancy. Percutaneous transvenous mitral commissurotomy (PTMC) has become the first-choice treatment, but is routinely performed with fluoroscopic guidance, which bears risks from ionizing radiation for the embryo when performed in pregnant patients., Case Presentation: A pregnant patient was referred to our department for therapy of severe MS after she suffered from cerebral artery infarction. The patient underwent successful PTMC under exclusive echocardiographic imaging and showed stable results throughout the pregnancy. The patient showed an improvement in functional capacity from dyspnoea New York Heart Association (NYHA) III to I and delivered a healthy child without any complications., Discussion: This case shows that PTMC of MS under exclusive echocardiography guidance without fluoroscopy is feasible and appears to be safe without causing radiation damage to the embryo.
- Published
- 2018
- Full Text
- View/download PDF
17. Explorative analysis of IPA-SPECT data through statistical inference for an automated diagnosis of glioma tumor.
- Author
-
Ubben T, Kluge A, Abolmaali N, and Iannilli E
- Subjects
- Automation, Humans, Glioma diagnostic imaging, Image Interpretation, Computer-Assisted methods, Statistics as Topic, Tomography, Emission-Computed, Single-Photon
- Abstract
Purpose: The identification of a brain tumor imaged with PET or SPECT is usually performed with visual inspection of an expert medical clinician. However an automated diagnostic of such images hasn't been established or applied. In this study, we explored the possibility of establishing an automated statistical analysis for the diagnosis of glioma by means of IPA-SPECT data., Methods: On the basis of a dataset of 100 patients that have undergone MRI and IPA-SPECT acquisition, in this work, we identify an automated workflow. Three different approaches were explored: I. statistical non-parametric mapping analysis (SnPM), II. statistical non-parametric analysis with an increased number of permutations due to sign-flipping function (PALM) and III. statistical parametric analysis (SPM). The automated methods were compared with the visual inspection., Results: The study proved PALM and SPM approaches to have a high diagnostic power. Compared to the parametric methods, the non-parametric method is the mathematically correct approach for the problem in question. If we take the high resolution structural MRI information into account, the diagnostic power of PALM was not significantly inferior to the visual inspection (P = 0.5150), showing an area under the ROC curve (AUC) smaller only by less than 3%., Conclusions: The automated diagnostic method based on statistical inference, here applied to diagnose glioma tumors in IPA-SPECT data, seems to be a promising tool that can support the visual investigation in nuclear medicine. Moreover in the foreseeable future, the presented methodology has a big potential in various application like localization of active tumor tissues in surgical resection or stereotactic radiosurgery., (© 2018 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.)
- Published
- 2018
- Full Text
- View/download PDF
18. Transcatheter Aortic Valve Replacement in Pure Native Aortic Valve Regurgitation.
- Author
-
Yoon SH, Schmidt T, Bleiziffer S, Schofer N, Fiorina C, Munoz-Garcia AJ, Yzeiraj E, Amat-Santos IJ, Tchetche D, Jung C, Fujita B, Mangieri A, Deutsch MA, Ubben T, Deuschl F, Kuwata S, De Biase C, Williams T, Dhoble A, Kim WK, Ferrari E, Barbanti M, Vollema EM, Miceli A, Giannini C, Attizzani GF, Kong WKF, Gutierrez-Ibanes E, Jimenez Diaz VA, Wijeysundera HC, Kaneko H, Chakravarty T, Makar M, Sievert H, Hengstenberg C, Prendergast BD, Vincent F, Abdel-Wahab M, Nombela-Franco L, Silaschi M, Tarantini G, Butter C, Ensminger SM, Hildick-Smith D, Petronio AS, Yin WH, De Marco F, Testa L, Van Mieghem NM, Whisenant BK, Kuck KH, Colombo A, Kar S, Moris C, Delgado V, Maisano F, Nietlispach F, Mack MJ, Schofer J, Schaefer U, Bax JJ, Frerker C, Latib A, and Makkar RR
- Subjects
- Aged, Aged, 80 and over, Catheterization, Peripheral methods, Catheterization, Peripheral statistics & numerical data, Female, Humans, International Cooperation, Male, Mortality, Outcome and Process Assessment, Health Care, Prosthesis Design trends, Quality Improvement, Registries statistics & numerical data, Risk Assessment, Severity of Illness Index, Aortic Valve surgery, Aortic Valve Insufficiency diagnosis, Aortic Valve Insufficiency mortality, Aortic Valve Insufficiency surgery, Femoral Artery surgery, Heart Valve Prosthesis adverse effects, Heart Valve Prosthesis standards, Postoperative Complications diagnosis, Postoperative Complications epidemiology, Transcatheter Aortic Valve Replacement adverse effects, Transcatheter Aortic Valve Replacement instrumentation, Transcatheter Aortic Valve Replacement methods, Transcatheter Aortic Valve Replacement statistics & numerical data
- Abstract
Background: Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR)., Objectives: This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR., Methods: From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices., Results: A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001). Compared with the early-generation devices, the new-generation devices were associated with a significantly higher device success rate (81.1% vs. 61.3%; p < 0.001) due to lower rates of second valve implantation (12.7% vs. 24.4%; p = 0.007) and post-procedural AR ≥ moderate (4.2% vs. 18.8%; p < 0.001). There were no significant differences in major 30-day endpoints between the 2 groups. The cumulative rates of all-cause and cardiovascular death at 1-year follow-up were 24.1% and 15.6%, respectively. The 1-year all-cause mortality rate was significantly higher in the patients with post-procedural AR ≥ moderate compared with those with post-procedural AR ≤ mild (46.1% vs. 21.8%; log-rank p = 0.001). On multivariable analysis, post-procedural AR ≥ moderate was independently associated with 1-year all-cause mortality (hazard ratio: 2.85; 95% confidence interval: 1.52 to 5.35; p = 0.001)., Conclusions: Compared with the early-generation devices, TAVR using the new-generation devices was associated with improved procedural outcomes in treating patients with pure native AR. In patients with pure native AR, significant post-procedural AR was independently associated with increased mortality., (Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Published
- 2017
- Full Text
- View/download PDF
19. High Sequence Variability of the ppE18 Gene of Clinical Mycobacterium tuberculosis Complex Strains Potentially Impacts Effectivity of Vaccine Candidate M72/AS01E.
- Author
-
Homolka S, Ubben T, and Niemann S
- Subjects
- Animals, Antigens, Bacterial genetics, Bacterial Proteins genetics, Genetic Heterogeneity, Humans, Mycobacterium tuberculosis immunology, Mycobacterium tuberculosis pathogenicity, Polymorphism, Single Nucleotide, Toll-Like Receptor 2 genetics, Toll-Like Receptor 2 metabolism, Tuberculosis microbiology, Tuberculosis prevention & control, Tuberculosis Vaccines genetics, Tuberculosis Vaccines therapeutic use, Antigens, Bacterial immunology, Bacterial Proteins immunology, Mycobacterium tuberculosis genetics, Tuberculosis immunology, Tuberculosis Vaccines immunology
- Abstract
The development of an effective vaccine is urgently needed to fight tuberculosis (TB) which is still the leading cause of death from a single infectious agent worldwide. One of the promising vaccine candidates M72/AS01E consists of two proteins subunits PepA and PPE18 coded by Rv0125 and Rv1196. However, preliminary data indicate a high level of sequence variability among clinical Mycobacterium tuberculosis complex (MTBC) strains that might have an impact on the vaccine efficacy. To further investigate this finding, we determined ppE18 sequence variability in a well-characterized reference collection of 71 MTBC strains from 23 phylogenetic lineages representing the global MTBC diversity. In total, 100 sequence variations consisting of 96 single nucleotide polymorphisms (SNPs), three insertions and one deletion were detected resulting in 141 variable positions distributed over the entire gene. The majority of SNPs detected were non-synonymous (n = 68 vs. n = 28 synonymous). Strains from animal adapted lineages, e.g., M. bovis, showed a significant higher diversity than the human pathogens such as M. tuberculosis Haarlem. SNP patterns specific for different lineages as well as for deeper branches in the phylogeny could be identified. The results of our study demonstrate a high variability of the ppE18 gene even in the N-terminal domains that is normally highly conserved in ppe genes. As the N-terminal region interacts with TLR2 receptor inducing a protective anti-inflammatory immune response, genetic heterogeneity has a potential impact on the vaccine efficiency, however, this has to be investigated in future studies.
- Published
- 2016
- Full Text
- View/download PDF
20. High resolution discrimination of clinical Mycobacterium tuberculosis complex strains based on single nucleotide polymorphisms.
- Author
-
Homolka S, Projahn M, Feuerriegel S, Ubben T, Diel R, Nübel U, and Niemann S
- Subjects
- Animals, Genes, Bacterial physiology, Genotyping Techniques, Humans, Algorithms, Evolution, Molecular, Host-Pathogen Interactions genetics, Mycobacterium tuberculosis genetics, Polymorphism, Single Nucleotide, Quantitative Trait Loci, Tuberculosis genetics, Virulence Factors genetics
- Abstract
Recently, the diversity of the Mycobacterium tuberculosis complex (MTBC) population structure has been described in detail. Based on geographical separation and specific host pathogen co-evolution shaping MTBC virulence traits, at least 20 major lineages/genotypes have evolved finally leading to a clear influence of strain genetic background on transmissibility, clinical presentation/outcome, and resistance development. Therefore, high resolution genotyping for characterization of strains in larger studies is mandatory for understanding mechanisms of host-pathogen-interaction and to improve tuberculosis (TB) control. Single nucleotide polymorphisms (SNPs) represent the most reliable markers for lineage classification of clinical isolates due to the low levels of homoplasy, however their use is hampered either by low discriminatory power or by the need to analyze a large number of genes to achieve higher resolution. Therefore, we carried out de novo sequencing of 26 genes (approx. 20000 bp per strain) in a reference collection of MTBC strains including all major genotypes to define a highly discriminatory gene set. Overall, 161 polymorphisms were detected of which 59 are genotype-specific, while 13 define deeper branches such as the Euro-American lineage. Unbiased investigation of the most variable set of 11 genes in a population based strain collection (one year, city of Hamburg, Germany) confirmed the validity of SNP analysis as all strains were classified with high accuracy. Taken together, we defined a diagnostic algorithm which allows the identification of 17 MTBC phylogenetic lineages with high confidence for the first time by sequencing analysis of just five genes. In conclusion, the diagnostic algorithm developed in our study is likely to open the door for a low cost high resolution sequence/SNP based differentiation of the MTBC with a very high specificity. High throughput assays can be established which will be needed for large association studies that are mandatory for detailed investigation of host-pathogen-interaction during TB infection.
- Published
- 2012
- Full Text
- View/download PDF
21. Evaluation of Mycobacterium tuberculosis typing methods in a 4-year study in Schleswig-Holstein, Northern Germany.
- Author
-
Roetzer A, Schuback S, Diel R, Gasau F, Ubben T, di Nauta A, Richter E, Rüsch-Gerdes S, and Niemann S
- Subjects
- Cluster Analysis, DNA Fingerprinting methods, Genotype, Germany, Humans, Mycobacterium tuberculosis isolation & purification, Polymorphism, Genetic, Molecular Typing methods, Mycobacterium tuberculosis classification, Mycobacterium tuberculosis genetics, Tuberculosis microbiology
- Abstract
In order to evaluate the discriminatory power of different methods for genotyping of Mycobacterium tuberculosis complex (MTBC) isolates, we compared the performance of (i) IS6110 DNA fingerprint typing, (ii) spoligotyping, and (iii) 24-loci mycobacterial interspersed repetitive units-variable number of tandem repeats (MIRU-VNTR) typing in a long-term study on the epidemiology of tuberculosis (TB) in Schleswig-Holstein, the northernmost federal state of Germany. In total, we analyzed 277 MTBC isolates collected from patients between the years 2006 and 2010. The collection comprised a broad spectrum of 13 different genotypes, among which strains of the Haarlem genotype (31%) were most prominent, followed by strains belonging to the Delhi and Beijing lineages (7% and 6%, respectively). On the basis of IS6110 restriction fragment length polymorphism (RFLP) and spoligotyping analyses, 211 isolates had unique patterns (76%) and 66 isolates (24%) were in 20 clusters. MIRU-VNTR combined with spoligotyping analyses revealed 202 isolates with unique patterns (73%) and 75 isolates in 18 clusters (27%). Overall, there was 93.1% concordance between the typing results obtained; 198 strains were identified as unique, and 60 isolates were clustered by both typing combinations (including all 31 isolates with confirmed epidemiological links). Of the remaining 19 isolates with discrepant results, 15 were falsely clustered by MIRU-VNTR (six Beijing genotype strains) and four were clustered by IS6110 RFLP (low IS6110 copy number) only. In conclusion, in the study population investigated, a minority of isolates, especially of the Beijing genotype, clustered by standard 24-loci MIRU-VNTR and without an obvious epidemiological link may require second-line typing by IS6110 RFLP or hypervariable MIRU-VNTR loci.
- Published
- 2011
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.