1. A prototype HBD for PHENIX
- Author
-
T. Vongpaseuth, S. C. Johnson, H. Chung, M. Akopyan, T. Piazza, T. K. Hemmick, and R.P. Pisani
- Subjects
Physics ,Nuclear and High Energy Physics ,Wire chamber ,Physics::Instrumentation and Detectors ,Cherenkov detector ,Detector ,Photocathode ,law.invention ,Nuclear physics ,Pion ,law ,Radiator (engine cooling) ,Electron efficiency ,Instrumentation - Abstract
We constructed and tested a threshold Cherenkov detector (inspired by the conceptual design of Giomataris and Charpak (Nucl. Instr. and Meth. A 310 (1991) 589 ) consisting of a gas radiator followed by a photosensitive wire chamber using a solid CsI photocathode. The detector was operated with C2F6 radiator gas and a 95%He+5%CH4 mixture for the avalanche gas. At 95% electron efficiency, the pion efficiency was 1 333 , 1 150 , and 1 100 for each of the lengths listed above.
- Published
- 1999
- Full Text
- View/download PDF