1. Development of Diamond-Based Pass-Through Diagnostics for Next-Generation XFELs
- Author
-
Zhu,Diling, Kachiguine,Serguei, Potter,Emma, Prebys,Eric, Nizam,Mohammad, Harris,Charles, Norvell,Nora, Kim,Dongsung, Prakash,Tarun, Wilder,Max, Mazza,Simone, Martinez-Mckinney,Forest, Ryan,Eric, Gonzalez,Eric, MacArthur,James, Bohon,Jen, Schumm,Bruce, Silva Torrecilla,Isleydys, Jacobson,Bryce, Smedley,John, Grace,Carl, Tarka,Michal, Padilla,Rene, and Stuart,David
- Subjects
photon-beamline-instrumentation-undulators - Photon beamline instrumentation & undulators ,Accelerator Physics - Abstract
FELs deliver rapid pulses on the femtosecond scale, and high peak intensities that fluctuate strongly on a pulse-to-pulse basis. The fast drift velocity and high radiation tolerance properties of chemical vapor deposition (CVD) diamonds make these crystals a good candidate material for developing a high frame rate pass-through diagnostic for the next generation of XFELs. We report on two diamond based diagnostic systems being developed by a collaboration of a UC campuses and National Laboratories supported by the University of California and the SLAC National Laboratory. For the first of these diagnostic systems, we have developed a new approach to the readout of diamond diagnostic sensors designed to facilitate operation as a passthrough detection system for high frame-rate XFEL diagnostics. Making use of the X-ray Pump Probe (XPP) beam at the Linac Coherent Light Source (LCLS), the performance of this new diamond sensor system has been characterized and compared to that of a commercially available system. Limits in the magnitude and speed of signal charge collection are explored as a function of the generated electron-hole plasma density and compared to results from a TCAD simulation. A leading proposal for improving the efficiency of producing longitudinally coherent FEL pulses is the cavity-based X-ray free electron laser (CBFEL). In this configuration, the FEL pulses are recirculated within an X-ray cavity in such a way that the fresh electron bunches interact with the FEL pulses stored in the cavity over multiple passes. This creates a need for diagnostics that can measure the intensity and centroid of the X-ray beam on every pass around the recirculatory path. For the second of these diagnostic systems, we have created a four-channel, position-sensitive pass-through diagnostic system that can measure the intensity and centroid of the circulating beam with a repetition rate in excess of 20 MHz. The diagnostic makes use of a planar diamond sensor thinned to 43 µm to allow for minimal absorption and wave-front distortion of the circulating beam. We present results on the response and position sensitivity of the diagnostic, again measured using the LCLS XPP beam.
- Published
- 2023
- Full Text
- View/download PDF