42 results on '"Siemens ADVIA Centaur"'
Search Results
2. Performance evaluation of nine different syphilis serological tests in comparison with the FTA-abs test
- Author
-
Cemile Sonmez, Figen Sezen, and Selçuk Kiliç
- Subjects
0301 basic medicine ,medicine.medical_specialty ,Routine testing ,Immunology ,Enzyme-Linked Immunosorbent Assay ,urologic and male genital diseases ,Serology ,03 medical and health sciences ,0302 clinical medicine ,Predictive Value of Tests ,Internal medicine ,Siemens ADVIA Centaur ,parasitic diseases ,medicine ,Humans ,Immunology and Allergy ,Syphilis ,Treponema pallidum ,Treponema ,medicine.diagnostic_test ,biology ,business.industry ,Reproducibility of Results ,Fluorescent Treponemal Antibody-Absorption Test ,biology.organism_classification ,Serum samples ,medicine.disease ,Antibodies, Bacterial ,Test (assessment) ,030104 developmental biology ,Immunoglobulin M ,Immunoglobulin G ,Immunoassay ,business ,Biomarkers ,030215 immunology - Abstract
Background Serological methods have great importance for the detection of Treponema pallidum antibodies in syphilis diagnosis. The goal of the present study is to evaluate various commercially available screening assays in comparison with the FTA-abs test. Methods A total of 363 serum samples were enrolled in the study. Following routine testing including RPR and TPHA tests, each sample was tested by treponemal immunoassays (Chorus Syphilis Screen Recombinant, Architect Syphilis TP, Syphilis Virclia Monotest, Siemens Advia Centaur Syphilis, Euroimmun Treponema pallidum Screen ELISA, Vircell Syphilis ELISA IgG + IgM, SD Bioline Syphilis). The result obtained from each test was compared with the confirmatory FTA-abs test. Kappa (κ) coefficients were used to compare the concordance of the tests. Results When the various tests were evaluated in comparison with the FTA-abs test, the sensitivity, specificity and percent agreement of each test were as follows: Architect Syphilis TP, 92.3%, 94.5%, 92.8%; Chorus Syphilis Screen Recombinant, 87.9%, 91.2%, 88.7%; Syphilis Virclia Monotest, 80.5%, 97.8%, 84.9%; Siemens Advia Centaur Syphilis, 87.5%, 89%, 87.9%; Euroimmun Treponema pallidum Screen ELISA, 87.5%, 85.7%, 87.1%; Vircell Syphilis ELISA IgG + IgM, 73.2%, 62.6%, 70.5%; TPHA, 89%, 63.7%, 82.6%; SD Bioline Syphilis, 58.1%, 94.5%, 67.2%; RPR test, 57.7%, 57.1%, 57.6%. Conclusion The results of the present study show that Treponema pallidum specific immunoassays with a performance similar or better than TPHA test generally performed well with the confirmatory FTA-abs test and may be an alternative for screening total antibodies in syphilis infection.
- Published
- 2019
- Full Text
- View/download PDF
3. [Bioclinical comparison of two high sensitivity cardiac troponin I assays: Siemens ADVIA Centaur versus Mitsubishi PathFast]
- Author
-
Gaspard Beaune, Capucine Arrivé, Loic Belle, Sandrine Boutruche, and Thomas Rocher
- Subjects
Cardiac troponin ,biology ,business.industry ,Point-of-Care Systems ,Transferability ,Troponin I ,General Medicine ,Point of care device ,Troponin ,Sensitivity and Specificity ,High sensitivity troponin ,Siemens ADVIA Centaur ,biology.protein ,Medicine ,Humans ,Biological Assay ,Nuclear medicine ,business ,Laboratories ,Biomarkers ,Point of care - Abstract
High-sensitivity troponin has become an essential emergency biomarker for diagnosing or ruling out an ACS. The establishment of a point of care biology related to the reorganization and fusion of laboratories raise a question about transferability of results between techniques. In this study, we propose to compare the bioclinical performances of high-sensitivity troponin measured by two different techniques on laboratory immunoanalyzer (Siemens Advia Centaur XPT) and on point of care device (Mitsubishi Pathfast). The assay of high-sensitivity troponin (n = 90 patients), according to our study, show consistent clinical results with both method.
- Published
- 2021
4. Sensitivity of the Elecsys Anti-SARS-CoV-2 immunoassay as an aid in determining previous exposure to SARS-CoV-2
- Author
-
Tina Laengin, Johannes Kolja Hegel, Christopher M. Rank, Peter Findeisen, Elena Riester, and Florina Langen
- Subjects
medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) ,Ethics committee ,Roche Diagnostics ,Confidence interval ,Patient level data ,Siemens ADVIA Centaur ,Immunoassay ,Internal medicine ,Global policy ,medicine ,business - Abstract
BackgroundThe Elecsys® Anti-SARS-CoV-2 electrochemiluminescence immunoassay (Roche Diagnostics International Ltd) was developed for the in vitro qualitative detection of antibodies to SARS-CoV-2. We evaluated the sensitivity of the Elecsys Anti-SARS-CoV-2 immunoassay in samples from a diverse cross-section of patients across multiple sites and compared results against commercially available comparators.MethodsSensitivity of the Elecsys Anti-SARS-CoV-2 immunoassay was evaluated using anonymised, frozen, residual single and sequential serum and plasma samples from patients with polymerase chain reaction (PCR)-confirmed SARS-CoV-2 infection. Point estimates and 95% confidence intervals (CIs) were calculated and method comparisons performed versus the following comparator assays: Euroimmun Anti-SARS-CoV-2 IgG, Abbott ARCHITECT SARS-CoV-2 IgG, Siemens ADVIA Centaur SARS-CoV-2 Total, and YHLO iFlash SARS-CoV-2 IgG and IgM.ResultsOverall sensitivity for the Elecsys Anti-SARS-CoV-2 immunoassay in 219 samples drawn ≥14 days post-PCR confirmation was 93.6% (95% CI 89.5–96.5). Across the three study sites, sensitivity in samples drawn ≥14 days post-PCR confirmation ranged from 85.7–98.9%. Sensitivity was significantly higher for the Elecsys Anti-SARS-CoV-2 immunoassay compared with the YHLO iFlash SARS-CoV-2 IgM assay for samples drawn ≥14 days post-PCR confirmation (86.3% [95% CI 76.7–92.9] versus 33.8% [95% CI 23.6–45.2]). Both Siemens ADVIA Centaur SARS-CoV-2 Total and YHLO iFlash SARS-CoV-2 IgG assays had a significantly higher sensitivity compared with the Elecsys Anti-SARS-CoV-2 immunoassay for samples drawn ≥14 days post-PCR confirmation (95.1% [95% CI 87.8–98.6] versus 85.2% [95% CI 75.6–92.1]; 93.8% [95% CI 86.0–97.9] versus 86.3% [95% CI 76.7–92.9]). Differences in sensitivity between the Elecsys Anti-SARS-CoV-2 immunoassay and the Euroimmun Anti-SARS-CoV-2 IgG (90.3% [95% CI 83.7–94.9] versus 95.2% [95% CI 89.8–98.2]) and Abbott ARCHITECT SARS-CoV-2 IgG (84.8% [95% CI 75.0–91.9] versus 87.3% [95% CI 78.0–93.8]) assays for samples drawn ≥14 days post-PCR confirmation were not significant.ConclusionsThe Elecsys Anti-SARS-CoV-2 immunoassay demonstrated high sensitivity in samples collected ≥14 days post-PCR confirmation of SARS-CoV-2 infection, and comparable sensitivity to several commercially available comparator assays across multiple sites, supporting the use of this assay as a tool to aid in determination of previous exposure to SARS-CoV-2.Required information for submission systemEthical guidelinesThe study was conducted in accordance with the study protocol provided by Roche Diagnostics and in accordance with the principles of the Declaration of Helsinki. All human samples utilised at the three study sites in Germany (Augsburg, Heidelberg, Berlin) were anonymised, frozen, residual samples, therefore no ethical approval or waiver was required in accordance with local legislation from ZEKO (Central Ethics Commission at the German Medical Association). A statement was obtained from the Ethics Committee of the Landesärztekammer Bayern confirming that there are no objections to the coherent use of anonymised residual samples.Research reporting guidelinesPlease see separate STARD checklist.Data availability statementQualified researchers may request access to individual patient level data through the clinical study data request platform (https://vivli.org/). Further details on Roche’s criteria for eligible studies are available here: https://vivli.org/members/ourmembers/. For further details on Roche’s Global Policy on the Sharing of Clinical Information and how to request access to related clinical study documents, see here: https://www.roche.com/research_and_development/who_we_are_how_we_work/clinical_trials/our_commitment_to_data_sharing.htm
- Published
- 2021
- Full Text
- View/download PDF
5. False elevation of serum cortisol in chemiluminescence immunoassay by Siemens Advia Centaur XP system in 21-hydroxylase deficiency: an ‘endocrine laboma’
- Author
-
Anirban Sinha, Neeti Agrawal, Partha Pratim Chakraborty, and Animesh Maiti
- Subjects
Male ,endocrine system ,medicine.medical_specialty ,Luminescence ,Adrenal disorder ,Hydrocortisone ,Chemiluminescence immunoassay ,030209 endocrinology & metabolism ,Lessons Learned ,03 medical and health sciences ,0302 clinical medicine ,Siemens ADVIA Centaur ,Internal medicine ,medicine ,Endocrine system ,Humans ,In patient ,False Positive Reactions ,Siemens Immulite ,Immunoassay ,biology ,Adrenal Hyperplasia, Congenital ,business.industry ,21-Hydroxylase ,Infant ,General Medicine ,Endocrinology ,Child, Preschool ,biology.protein ,Female ,business ,030217 neurology & neurosurgery ,Serum cortisol - Abstract
Liquid chromatography–mass spectrometry, the gold standard method for cortisol measurement, is expensive and not widely available in the developing countries. Chemiluminescent immunoassay, commonly used for cortisol measurement is prone to clinically meaningful inter-assay variability in some analysers. This occurs due to non-specific nature of anticortisol antibodies used in different platforms, having cross reactivity with structurally similar cortisol precursors like 17α-hydroxyprogesterone (17OHP), 11-deoxycortisol and 21-deoxycortisol. In patients with 21-hydroxylase deficiency, where 17OHP and 21-deoxycortisol are significantly elevated, older generation machines like Siemens Advia Centaur XP provide spuriously high cortisol concentration compared with values measured by Roche Cobas e 411 or Siemens Immulite 1000. Diagnosis of potentially life-threatening salt-wasting 21-hydroxylase deficiency may be missed and treatment may be delayed due to such interference. Two children with classic 21-hydroxylase deficiency are being reported here, in whom high cortisol values were observed in Siemens Advia Centaur XP system.
- Published
- 2020
6. Correlation of ELISA based with random access serologic immunoassays for identifying adaptive immune response to SARS-CoV-2
- Author
-
Li Chen, Alejandro C. Arroliga, Walter Linz, Arundhati Rao, Priscilla R. Powell, Liping Wang, Lam T. Nguyen, Nguyen N. Nguyen, Richard R. Gomez, Dapeng Wang, Yinan Hua, Amin A. Mohammad, Manohar B. Mutnal, Colin C. McCormack, Huy N. Pham, and William Koss
- Subjects
medicine.medical_specialty ,Emergency Use Authorization ,medicine.diagnostic_test ,Coronavirus disease 2019 (COVID-19) ,business.industry ,Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) ,Concordance ,Diagnostic test ,Serology ,Internal medicine ,Immunoassay ,Siemens ADVIA Centaur ,medicine ,business - Abstract
Public health emergency of SARS-CoV-2 has facilitated diagnostic testing as a related medical countermeasure against COVID-19 outbreak. Numerous serologic antibody tests have become available through an expedited federal emergency use only process. This paper highlights the analytical characteristic of an ELISA based assay by AnshLabs and three random access immunoassay (RAIA) by DiaSorin, Roche, and Abbott that have been approved for emergency use authorization (EUA), at a tertiary academic center in a low disease-prevalence area. The AnshLabs gave higher estimates of sero-prevalence, over the three RAIA methods. For positive results, AnshLabs had 93.3% and 100% concordance with DiaSorin or Abbott and Roche respectively. For negative results, AnshLabs had 69.7% and 73.0% concordance with DiaSorin and Roche or Abbott respectively. All discrepant samples that were positive by AnshLabs and negative by RAIA tested positive by all-in-one step SARS-CoV-2 Total (COV2T) assay performed on the automated Siemens Advia Centaur XPT analyzer. None of these methods, however, are useful in early diagnosis of SARS-CoV-2.
- Published
- 2020
- Full Text
- View/download PDF
7. Comparison of four matrixes for diluting insulin in routine clinical measurements
- Author
-
Xinqi Cheng, Honglei Li, Qiong Wu, Danchen Wang, Xiuzhi Guo, and Liangyu Xia
- Subjects
Quality Control ,0301 basic medicine ,Microbiology (medical) ,insulin ,medicine.medical_treatment ,Clinical Biochemistry ,Serum insulin ,Indicator Dilution Techniques ,Diluent ,recovery ,03 medical and health sciences ,0302 clinical medicine ,Siemens ADVIA Centaur ,medicine ,Humans ,Immunology and Allergy ,Research Articles ,Immunoassay ,diluent ,Chromatography ,Chemistry ,Insulin ,Biochemistry (medical) ,Public Health, Environmental and Occupational Health ,Hematology ,Serum samples ,matrix ,Dilution ,Medical Laboratory Technology ,030104 developmental biology ,Dilution ratio ,Linear range ,030220 oncology & carcinogenesis ,Research Article - Abstract
Objective In our laboratory, 2.36% (6626/280765) samples obtained for insulin evaluation have serum insulin concentrations higher than 300 mU/L, resulting in curves outside the linear range in the insulin release test (IRT). Accordingly, using appropriate dilution protocols to determine insulin concentration accurately is important. Here, we compared the effectiveness and economy of four different solutions for diluting high‐insulin serum in routine clinical measurements. Method Residual serum samples with high‐insulin concentrations ranging from 200 to 300 mU/L were collected in Peking Union Medical College Hospital from August to November 2017. Four different matrixes including a Siemens original diluent, pure water, 0.9% NaCl, and low‐insulin serum (labeled as A to D, respectively) were used to dilute the serum in the ratios of 1:2, 1:5, and 1:10. Results We found that the linear correlation coefficients of A to D were higher than 0.9. The recovery rates of A to D were 86.4%–104.0%, 73.2%–99.3%, 76.4%–101.3%, and 84.2%–99.7%, respectively. We conclude that the use of 0.9% NaCl, pure water, or low‐insulin serum to dilute high‐serum insulin (>300 mU/L) is feasible and cost‐effective. Conclusion We recommend a dilution factor of 1:5 on a Siemens ADVIA Centaur XP® instrument. The clinically reported range was 0.5‐1500 mU/L. For specific samples (>1500 mU/L), we recommended using low‐insulin serum samples for dilution.
- Published
- 2020
- Full Text
- View/download PDF
8. Evaluation of the Siemens ADVIA Centaur high-sensitivity cardiac troponin I assay in serum
- Author
-
Andrew Worster, Peter A. Kavsak, Allan S. Jaffe, and Stephen Hill
- Subjects
Male ,Cardiac troponin ,Clinical Biochemistry ,Population ,Siemens ,030204 cardiovascular system & hematology ,Chest pain ,Biochemistry ,03 medical and health sciences ,0302 clinical medicine ,Siemens ADVIA Centaur ,Troponin I ,Humans ,Medicine ,education ,Aged ,Aged, 80 and over ,education.field_of_study ,business.industry ,Biochemistry (medical) ,Area under the curve ,General Medicine ,Middle Aged ,Serum samples ,ROC Curve ,030220 oncology & carcinogenesis ,Female ,medicine.symptom ,business ,Nuclear medicine ,Blood Chemical Analysis - Abstract
International recommendations on high-sensitivity cardiac troponin (hs-cTn) testing recommend that laboratories select only one sample type for testing. We evaluated the Siemens ADVIA Centaur hs-cTnI assay in serum and thereby provide information on imprecision, long-term storage stability, freeze-thaw stability, method comparison to other hs-cTnI assays, and clinical performance.Patients with chest pain onset6 h who already had Roche hs-cTnT, Beckman hs-cTnI and Abbott hs-cTnI results recorded and had non-thawed and frozen serum aliquots formed the study population (n = 134 patients with 305 serum aliquots obtained at either 0, 3 or 6 h stored below -70 °C since 2003) for measurement with the Siemens hs-cTnI assay in 2018. Receiver-operating characteristic curve analyses for myocardial infarction (MI) using the highest obtained hs-cTn concentration was performed. Additional comparison testing on serum samples stored frozen (at -70 °C for1 month in 2018) for the Siemens and Abbott hs-cTnI assays were performed, as well as precision testing in serum pools and freeze-thaw stability testing.The Siemens hs-cTnI assay had an area under the curve (AUC) of 0.978 (95%CI: 0.937-0.996) for MI in the study cohort (Roche hs-cTnT AUC = 0.965 and Abbott AUC = 0.973). The Siemens hs-cTnI assay yielded higher cTnI concentrations than the other hs-cTn assays, with the same proportional bias (slope = 1.4) between the Siemens and Abbott hs-cTnI assays obtained from serum samples collected in 2003 and 2018. Over 3 months, a low serum pool of 3.5 ng/l achieved a CV of 20% (SD = 0.7, n = 42) and a high serum pool of 820 ng/l achieved a CV of 2.3% (SD = 20, n = 42). Three different serum pools recovered within 10% from baseline concentration after 5 freeze-thaw cycles for the Siemens hs-cTnI assay.In serum, the Siemens ADVIA Centaur hs-cTnI assay had excellent clinical performance for MI in an early chest pain onset population, acceptable precision at normal and highly elevated cTnI concentrations, long-term storage stability (15 y storage below -70 °C) and acceptable freeze-thaw stability, all of which supports serum as an acceptable sample type to use in clinical studies and in clinical practice.
- Published
- 2018
- Full Text
- View/download PDF
9. Effects of sex, age, sampling time, and season on thyroid-stimulating hormone concentrations: A retrospective study
- Author
-
G. Xiuzhi, L. Honglei, W. Danchen, L. Dandan, X. Tao, L. Hongchun, Q. Ling, Y. Songlin, and C. Xinqi
- Subjects
Adult ,Male ,endocrine system ,Time Factors ,Adolescent ,endocrine system diseases ,Chemiluminescence immunoassay ,Clinical Biochemistry ,Biophysics ,Thyrotropin ,Physiology ,030209 endocrinology & metabolism ,Biochemistry ,Young Adult ,03 medical and health sciences ,Sex Factors ,0302 clinical medicine ,Thyroid-stimulating hormone ,Siemens ADVIA Centaur ,Outpatients ,medicine ,Humans ,Molecular Biology ,Aged ,business.industry ,Biochemistry (medical) ,Thyroid ,Age Factors ,Retrospective cohort study ,General Medicine ,Cell Biology ,Middle Aged ,TSH measurement ,medicine.anatomical_structure ,030220 oncology & carcinogenesis ,Linear Models ,Female ,Seasons ,Sampling time ,business ,hormones, hormone substitutes, and hormone antagonists ,Hormone - Abstract
Background Measuring thyroid-stimulating hormone (TSH) is essential for diagnosing and monitoring thyroid diseases. The aim of this study was to evaluate the effect of sex, age, sampling time and season on TSH in a large Chinese population and to determine which factor had the greatest impact on TSH measurement results. Methods Data were obtained from the laboratory information system from September 1, 2013 to August 31, 2016. A total of 80150 TSH measurements of outpatients were enrolled in this study. TSH was measured using a Siemens ADVIA Centaur XP automatic chemiluminescence immunoassay analyzer. Linear regression models were used to assess the association between log-transformed TSH concentrations and sex, age, sampling time and season. Results The serum TSH concentrations in women were significantly higher than in men. In all subjects, serum TSH concentrations increased by 0.005 μIU/mL for each year of age. TSH concentrations showed circannual variation during the 3 consecutive years of data collection and decreased during the summer while increased during the winter. The serum TSH concentrations decreased from 7 a.m. to 1 p.m. while increased from 1 p.m. to 4 p.m. The same trend was observed in TSH concentrations for sampling time stratified by sex. Linear regression revealed that sampling time might be the major factor affecting serum TSH concentrations. Conclusion Sex, age, season, and sampling time significantly affected serum TSH concentrations. Age-related alteration in serum TSH concentrations was observed in this study. Sampling time was the major factor affecting serum TSH concentrations.
- Published
- 2018
- Full Text
- View/download PDF
10. Accuracy of Two Progesterone Immunoassays for Monitoring In Vitro Fertilization
- Author
-
Sridevi Devaraj, Stephen M. Roper, Jessica Rubin, Mahesheema Ali, P.W. Zarutskie, and William E. Gibbons
- Subjects
030219 obstetrics & reproductive medicine ,In vitro fertilisation ,Chromatography ,medicine.diagnostic_test ,business.industry ,medicine.medical_treatment ,General Medicine ,Serum progesterone ,Serum samples ,03 medical and health sciences ,0302 clinical medicine ,Progesterone measurement ,Method comparison ,030220 oncology & carcinogenesis ,Immunoassay ,Siemens ADVIA Centaur ,Medicine ,Sample collection ,business - Abstract
Background Progesterone concentrations are routinely monitored during in vitro fertilization cycles. Immunoassay-based platforms are used most often in this setting because they are simple to use and amenable to same-day sample collection and result-reporting. However, immunoassay methods are subject to variation in specificity between different assay manufacturers. In this study, a set of unexpectedly high progesterone concentrations led to a method comparison between two in-house immunoassay platforms relative to the reference method. Methods Progesterone was measured in 28 serum samples from women undergoing IVF cycles using the Siemens ADVIA Centaur Immunoassay system and the Abbott Architect i1000SR analyzer. A subset of these samples was selected for progesterone measurement by liquid chromatography–tandem mass spectrometry to define the accuracy of each immunoassay. Results The Siemens ADVIA Centaur immunoassay system overestimated progesterone concentrations by 19% and the Abbott Architect overestimated progesterone concentrations by 5%. Conclusions The Abbott Architect progesterone immunoassay provides a more accurate measurement of serum progesterone than the Centaur immunoassay at concentrations relevant for monitoring in vitro fertilization populations.
- Published
- 2018
- Full Text
- View/download PDF
11. Performance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 Total 25-OH Vitamin D assays
- Author
-
Chen, Yu, Kinney, Lois, Božović, Andrea, Smith, Hilary, Tarr, Heather, Diamandis, Eleftherios P., and LeBlanc, Adrien
- Subjects
- *
BIOLOGICAL assay , *VITAMIN D , *HEMOLYSIS & hemolysins , *LIQUID chromatography-mass spectrometry , *IMMUNOASSAY , *PERFORMANCE evaluation , *EVALUATION - Abstract
Abstract: Objectives: To evaluate the newly developed Roche MODULAR Analytics E170 Total Vitamin D and the Siemens ADVIA Centaur® Vitamin D Total assays. Materials and Methods: Assays were evaluated using the Clinical and Laboratory Standards Institute protocols. Split patient samples were compared with LC-MS/MS and DiaSorin LIAISON assays (n =79 including 15 specimens with detectable endogenous 25-OH vitamin D2). Assay accuracy was also evaluated using the Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results: The ADVIA Centaur and E170 assays demonstrated maximum total CVs of 14.1% and 5.9%, respectively. Both showed excellent linearity (R 2 >0.99). The ADVIA Centaur assay demonstrated interference with bilirubin at 800μmol/L, hemolysis at 1.25g/L, and triglycerides at 2.8mmol/L. Compared to LC-MS/MS, the ADVIA Centaur assay demonstrated a R 2 value of 0.893, average bias of −8.8%; the E170 assay an R 2 value of 0.872, average bias of 14.3% with underestimation of 25-OH vitamin D2. Compared to the LIAISON assay, the ADVIA Centaur assay demonstrated an R 2 value of 0.781, average bias of −17.3%; the E170 assay an R 2 value of 0.823, average bias of 11.4%. The ADVIA Centaur and E170 assays demonstrated a biases of <20% in 10/10 and 8/10 DEQAS samples, respectively. Conclusions: The ADVIA Centaur and E170 vitamin D assays demonstrated acceptable linearity, imprecision, and accuracy. The E170 assay demonstrated consistent underestimation of 25-OH vitamin D2 levels. Compared with LC-MS/MS, the ADVIA Centaur assay demonstrated a higher R 2 value and a smaller average bias than the E170 assay. [Copyright &y& Elsevier]
- Published
- 2012
- Full Text
- View/download PDF
12. Impact of light exposure on thyroid-stimulating hormone results using the Siemens Advia Centaur TSH-3Ultra assay
- Author
-
Kathryn Brownbill, Ian Lancaster, Diane Giles, and Jane Armer
- Subjects
Quality Control ,030213 general clinical medicine ,medicine.medical_specialty ,Light ,Clinical Biochemistry ,Siemens ,Thyrotropin ,030204 cardiovascular system & hematology ,Specimen Handling ,03 medical and health sciences ,0302 clinical medicine ,Thyroid-stimulating hormone ,Siemens ADVIA Centaur ,Internal medicine ,medicine ,Humans ,Light exposure ,Immunoassay ,medicine.diagnostic_test ,business.industry ,General Medicine ,Endocrinology ,Thyroid hormones ,Thyroid function ,business ,Hormone - Abstract
Background Thyroid-stimulating hormone (TSH) is used as the first-line test of thyroid function. Siemens Healthcare Diagnostics recommend that Siemens Centaur reagents must be protected from light in the assay information and on reagent packaging. We have compared the effect of light exposure on results using Siemens TSH-3Ultra and follicle-stimulating hormone reagents. The thyroid-stimulating hormone reagent includes fluoroscein thiocyanate whereas the follicle-stimulating hormone reagent does not. Methods Three levels of quality controls were analysed using SiemensTSH-3Ultra and follicle-stimulating hormone reagent packs that had been kept protected from light or exposed to light at 6-h intervals for 48 h and then at 96 h. Results Thyroid-stimulating hormone results were significantly lower after exposure of TSH-3Ultra reagent packs to light. Results were >15% lower at all three levels of quality control following 18 h of light exposure and continued to decrease until 96 h. There was no significant difference in follicle-stimulating hormone results whether reagents had been exposed to or protected from light. Conclusions Thyroid-stimulating hormone results but not follicle-stimulating hormone results are lowered after exposure of reagent packs to light. Laboratories must ensure that TSH-3Ultra reagents are not exposed to light and analyse quality control samples on every reagent pack to check that there has not been light exposure prior to delivery. The labelling on TSH-3Ultra reagent packs should reflect the significant effect of light exposure compared with the follicle-stimulating hormone reagent. We propose that the effect of light exposure on binding of fluoroscein thiocyanate to the solid phase antibody causes the falsely low results.
- Published
- 2017
- Full Text
- View/download PDF
13. STUDY OF SERUM ELECTROLYTES IMBALANCES IN FEMALE THYROID PATIENTS AT AIIMS, PATNA: A HOSPITAL BASED COMPARATIVE STUDY
- Author
-
Mala Mahto, Dev Kant, and Jyoti Kumari
- Subjects
endocrine system ,medicine.medical_specialty ,Electrolytes sodium ,endocrine system diseases ,business.industry ,Thyroid ,Early detection ,Hospital based ,Gastroenterology ,medicine.anatomical_structure ,Paired samples ,Thyroid hormones ,Internal medicine ,Siemens ADVIA Centaur ,Medicine ,Serum electrolytes ,business ,hormones, hormone substitutes, and hormone antagonists - Abstract
Objectives: This present study was to compare the serum electrolytes (Na, K and Cl) imbalances in hypothyroidism, hyperthyroidism with euthyroidism female cases. Methods: A detail history, clinical examinations and relevant investigations were performed to all female thyroid cases. Thyroid hormones were estimated by chemiluminiscence method using Siemens Advia Centaur XP instrument. Electrolyte levels (Na+, k+ & Cl-) were measured by ion selective electrode method using Eschweiler combi. Results: Data was analyzed with the help of SPSS (version 26) software. Paired samples statistics was used. Mean ± standard deviation and t value were calculated. P value was taken less than or equal to 0.05 (p ≤ 0.05) for significant differences. Conclusions: This present study concluded that electrolytes sodium, potassium and chloride levels were significantly reduced in hypothyroidism female cases compared to euthyroids female (controls). This suggests that hypothyroid patients should be regularly checked for serum electrolytes. Early detection and treatment can prevent the further complications related to the disorder and will be helpful during the management of thyroid patients. Key words: Hypothyroidism, hyperthyroidism, euthyroidism, electrolytes.
- Published
- 2019
- Full Text
- View/download PDF
14. Assessing Diagnostic Accuracy of Serum Holotranscobalamin (Active-B12) in Comparison with Other Markers of Vitamin B12 Deficiency
- Author
-
Lakshmanan Jeyaseelan, Arun Jose Nellickal, F S Geethanjali, and Joseph Dian Bondu
- Subjects
0301 basic medicine ,Creatinine ,medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,Clinical Biochemistry ,Megaloblastic anaemia ,Diagnostic accuracy ,Positive correlation ,Gastroenterology ,03 medical and health sciences ,chemistry.chemical_compound ,030104 developmental biology ,0302 clinical medicine ,chemistry ,Body cells ,030220 oncology & carcinogenesis ,Internal medicine ,Siemens ADVIA Centaur ,medicine ,Vitamin B12 ,Original Research Article ,business ,Mean corpuscular volume - Abstract
About 15–40% India is Vitamin B12 deficient (commonly diagnosed by total Vitamin B12) but, as only holoTC (active form) is taken up by body cells, thus measuring holoTC is more reflective of Vitamin B12 status than the former. We aimed to assess diagnostic accuracy of serum holoTC in comparison with total Vitamin B12 and total Homocysteine (HCY) as indicator of serum Vitamin B12 status. 217 human subjects (99 males and 118 females) ranging from 17 to 83 years were divided into Vitamin B12 deficient (n = 70), borderline (n = 100) and sufficient groups (n = 47) who were further assessed for markers of Vitamin B12 deficiency—holoTC, HCY, Mean Corpuscular Volume (MCV), Folate, heamoglobin and creatinine. Samples were analysed using Siemens Advia Centaur Xpi. Total Vitamin B12 deficient group had − 84.3% holoTC deficient; 15.7% holoTC sufficient; 72.9% with elevated HCY; 27.1% with normal HCY; 11.4% with megaloblastic anaemia. Borderline group had − 34% holoTC deficient; 28% elevated HCY. A strong positive correlation was found between Total Vitamin B12 and holoTC (r = 0.754, p =
- Published
- 2019
15. Performance evaluation of two immunoassays for 25-hydroxyvitamin D
- Author
-
Zhongjian Xie, Jingjing Yuan, Lusha Li, and Qin Zeng
- Subjects
Vitamin ,Clinical Biochemistry ,Analytical chemistry ,Medicine (miscellaneous) ,030209 endocrinology & metabolism ,030204 cardiovascular system & hematology ,03 medical and health sciences ,chemistry.chemical_compound ,0302 clinical medicine ,Siemens ADVIA Centaur ,Lc ms ms ,medicine ,Vitamin D and neurology ,immunoassay ,LC-MS/MS ,Nutrition and Dietetics ,Chromatography ,medicine.diagnostic_test ,25(OH)D ,Chemistry ,Significant difference ,Healthy subjects ,Serum samples ,Immunoassay ,Elecsys ,Original Article ,Centaur - Abstract
Although immunoassays in measuring 25-hydroxyvitamin D [25(OH)D] have been improved recently, relatively large differences are still seen between results of 25(OH)D measured by immunoassays and by liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the present studies, we compared two immunoassays with LC-MS/MS for measuring 25(OH)D concentrations. Concentrations of 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] in serum samples from 59 healthy subjects were measured by two immunoassays including Siemens ADVIA Centaur Vitamin D Total (Centaur) and Roche Elecsys Vitamin D Total (Elecsys) and LC-MS/MS. To determine the cross reactivity of Elecsys and Centaur toward 25(OH)D2, a dosage of 200,000 IU vitamin D2 was given after first sampling. Serum samples were obtained 30 days later and concentrations of 25(OH)D2 and 25(OH)D3 were measured again. The results showed poor agreement between the immunoassays and LC-MS/MS in 25(OH)D2 and 25(OH)D3 measurements. The percentage of 25(OH)D2 cross-reactivity was 45.3% for Centaur and 41.2% for Elecsys and there was no significant difference between Centaur and Elecsys. In conclusion, Centaur and Elecsys perform unsatisfactorily in measuring 25(OH)D levels, especially for 25(OH)D2 cross-reactivity. Therefore, clinicians need to be aware of the underestimation of vitamin D status when using these immunoassays for measuring individuals supplemented with vitamin D2.
- Published
- 2016
16. Analytical validation of a conventional cardiac troponin I assay for dogs and cats
- Author
-
Rebecca Langhorn, Jacob D Yrfelt, Claus S Stjernegaard, Liselotte B Christiansen, Lise Nikolic Nielsen, and Lisbeth H. Olsen
- Subjects
030213 general clinical medicine ,medicine.medical_specialty ,Cardiac troponin ,040301 veterinary sciences ,Urology ,0403 veterinary science ,03 medical and health sciences ,0302 clinical medicine ,Blood serum ,Dogs ,Siemens ADVIA Centaur ,Troponin I ,Medicine ,Animals ,Detection limit ,Immunoassay ,CATS ,General Veterinary ,medicine.diagnostic_test ,business.industry ,Reproducibility of Results ,04 agricultural and veterinary sciences ,Serum samples ,Luminescent Measurements ,Cats ,business - Abstract
Background Cardiac troponins are gold-standard biomarkers of myocardial injury. There is a need for validation of assays with higher availability and lower costs in veterinary medicine. Objectives The primary aim of the present study was to perform an analytical validation of the IMMULITE 2000 TnI assay for use in dogs and cats. A secondary aim was to evaluate its agreement with the previously validated and sensitive Siemens ADVIA Centaur TnI-Ultra assay. Methods Intra- and inter-assay variation, detection limits, the linearity under dilution, and a sample addition study (modified spike-and-recovery analysis) were investigated to assess analytical performance in 15 canine and 15 feline serum samples. Agreement between the assays was evaluated by correlation and Bland-Altman analyses including an additional 99 canine serum samples. Results Intra-assay variation of cTnI in canine and feline serum was 3.71% and 4.68%, while inter-assay variation was 5.88% and 6.54%, respectively. The assay performed with acceptable linearity within a clinically relevant range of serum cTnI concentrations. The sample addition study revealed insufficient recovery in the range of 71.9%-81.4% for dogs and 62.6%-75.7% for cats. This was considered to be due to a negative matrix effect. A significant correlation between the assays was found, and the Bland-Altman analysis showed acceptable agreement for a wide range of concentrations, but revealed a proportional error, with the IMMULITE TnI assay consistently measuring a higher concentration than the Centaur TnI-Ultra assay. This was relevant only at high serum cTnI concentrations. Conclusions The IMMULITE TnI assay is considered acceptable for clinical use in dogs and cats.
- Published
- 2018
17. Detection of in vivo hepatitis B virus surface antigen mutations-A comparison of four routine screening assays
- Author
-
Giuseppina Brancaccio, Teresa Santantonio, Jérémie Gautier, Peter Gohl, G.B. Gaeta, P. T. T. Thuy, C. Reinsch, B. H. Hoang, Massimo Fasano, Stephan Pabinger, C. W. Spearman, E. Brill, Gaston Westergaard, Mark W. Sonderup, A. Woeste, Anja Seffner, Mikael Gencay, Hyun-Seok Kim, Wolfgang E. Kaminski, Richard Batrla, Dionissios Neofytos, M. Weizenegger, Gencay, M, Seffner, A, Pabinger, S, Gautier, J, Gohl, P, Weizenegger, M, Neofytos, D, Batrla, R, Woeste, A, Kim, H S, Westergaard, G, Reinsch, C, Brill, E, Thuy, P T T, Hoang, B H, Sonderup, M, Spearman, C W, Brancaccio, G, Fasano, M, and Gaeta, Giovanni Battista
- Subjects
0301 basic medicine ,HBsAg ,Hepatitis B virus ,Genotype ,Economic shortage ,“a” determinant region ,Hepatitis b surface antigen ,Sensitivity and Specificity ,Cohort Studies ,03 medical and health sciences ,Hepatitis B, Chronic ,In vivo ,Virology ,Siemens ADVIA Centaur ,HBsAg mutations ,Hbv genotype ,Medicine ,Humans ,Mass Screening ,HBV mutations ,Immunoassay ,Hepatitis B virus surface Antigen ,Routine screening ,Hepatitis B Surface Antigens ,Hepatology ,business.industry ,Diagnostic Tests, Routine ,HBV mutation ,virus diseases ,Hepatitis B ,digestive system diseases ,030104 developmental biology ,Infectious Diseases ,mutation spectrum ,Mutation ,business ,HBsAg mutation - Abstract
An important requirement for a state-of-the-art hepatitis B surface antigen (HBsAg) screening assay is reliable detection of mutated HBsAg. Currently, there is a striking shortage of data regarding the detection rates of in vivo HBsAg mutations for these clinically important assays. Therefore, we compared the detection rates of four commercial HBsAg screening assays using a global cohort of 1553 patients from four continents with known HBV genotypes. These samples, which represent the broadest spectrum of known and novel HBsAg major hydrophilic region (MHR) mutations to date, were analyzed for the presence of HBsAg using the Roche Elecsys® HBsAg II Qualitative, Siemens ADVIA Centaur XP HBsAg II, Abbott Architect HBsAg Qualitative II and DiaSorin Liaison® HBsAg Qualitative assays, respectively. Of the 1553 samples, 1391 samples could be sequenced; of these, 1013 (72.8%) carried at least one of the 345 currently known amino acid substitutions (distinct HBsAg mutation) in the HBsAg MHR. All 1553 patient samples were positive for HBsAg using the Elecsys® HBsAg II Qual assay, with a sensitivity (95% confidence interval) of 99.94% (99.64%-100%), followed by the Abbott Architect 99.81% (99.44%-99.96%), Siemens ADVIA 99.81% (99.44%-99.96%) and DiaSorin Liaison® 99.36% (98.82%-99.69%) assays, respectively. Our results indicate that the Elecsys® HBsAg II Qual assay exhibits the highest sensitivity among the commercial HBsAg screening assays, and demonstrate that its capacity to detect HBV infection is not compromised by HBsAg MHR mutants.
- Published
- 2018
18. Multicenter Comparison of Seven 25Oh Vitamin D Automated Immunoassays / Multicentrično Poređenje Sedam Automatizovanih Imunoeseja Za 25Oh Vitamin D
- Author
-
Giorgio Da Rin, Davide Giavarina, Mariella Dipalo, Giuseppe Lippi, Antonio Fortunato, Gian Luca Salvagno, and Rosalia Aloe
- Subjects
standardization ,Chromatography ,medicine.diagnostic_test ,business.industry ,poredenje metoda ,25OH-D ,vitamin D ,imunoeseji ,Serum samples ,immunoassays ,250H-D ,lcsh:Biochemistry ,standardizacija ,multicenter study ,Method comparison ,Multicenter study ,method comparison ,Siemens ADVIA Centaur ,Immunoassay ,Vitamin D and neurology ,Medicine ,lcsh:QD415-436 ,vitamin D, laboratory, multicenter study ,business ,laboratory - Abstract
SummaryBackground: The measurement of 25OH vitamin D continues to grow in clinical laboratories. The aim of this multicenter study was to compare the results of seven automated commercial immunoassays with a reference HPLC technique.Methods: One hundred and twenty consecutive outpatient serum samples were centrifuged, divided in aliquots, frozen and shipped to the participating laboratories. 25OH Vita - min D was measured with a reference HPLC system and with seven automated commercial immunoassays (Roche Cobas E601, Beckman Coulter Unicel DXI 800, Ortho Vitros ES, DiaSorin Liaison, Siemens Advia Centaur, Abbott Architect i System and IDS iSYS).Results: Compared to the reference method, the regression coefficients ranged from 0.923 to 0.961 (all pConclusions:The excellent correlation with the reference HPLC technique attests that all seven automated immuno - assays may be reliably used for routine assessment of 25OH-D in clinical laboratories. The significant bias among the different methods seems mostly attributable to the lack of standardization and calls for additional efforts for improving harmonization of 25OH-D immunoassays.
- Published
- 2015
19. The development of decision limits for the GH-2000 detection methodology using additional insulin-like growth factor-I and amino-terminal pro-peptide of type III collagen assays
- Author
-
Richard I. G. Holt, Nishan Guha, E. Eryl Bassett, Walailuck Böhning, Christiaan Bartlett, Peter H. Sönksen, Sylvain Giraud, Dankmar Böhning, and David A. Cowan
- Subjects
Type III collagen ,Oncology ,Engineering ,medicine.medical_specialty ,business.industry ,Amino terminal ,Pharmaceutical Science ,Analytical Chemistry ,Sample size determination ,Siemens ADVIA Centaur ,Internal medicine ,medicine ,Environmental Chemistry ,Elite athletes ,business ,Spectroscopy ,Decision limit - Abstract
The GH-2000 and GH-2004 projects have developed a method for detecting GH misuse based on measuring insulin-like growth factor-I (IGF-I) and the amino-terminal pro-peptide of type III collagen (P-III-NP). The objectives were to analyze more samples from elite athletes to improve the reliability of the decision limit estimates, to evaluate whether the existing decision limits needed revision, and to validate further non-radioisotopic assays for these markers. The study included 998 male and 931 female elite athletes. Blood samples were collected according to World Anti-Doping Agency (WADA) guidelines at various sporting events including the 2011 International Association of Athletics Federations (IAAF) World Athletics Championships in Daegu, South Korea. IGF-I was measured by the Immunotech A15729 IGF-I IRMA, the Immunodiagnostic Systems iSYS IGF-I assay and a recently developed mass spectrometry (LC-MS/MS) method. P-III-NP was measured by the Cisbio RIA-gnost P-III-P, Orion UniQ™ PIIINP RIA and Siemens ADVIA Centaur P-III-NP assays. The GH-2000 score decision limits were developed using existing statistical techniques. Decision limits were determined using a specificity of 99.99% and an allowance for uncertainty because of the finite sample size. The revised Immunotech IGF-I - Orion P-III-NP assay combination decision limit did not change significantly following the addition of the new samples. The new decision limits are applied to currently available non-radioisotopic assays to measure IGF-I and P-III-NP in elite athletes, which should allow wider flexibility to implement the GH-2000 marker test for GH misuse while providing some resilience against manufacturer withdrawal or change of assays.
- Published
- 2015
- Full Text
- View/download PDF
20. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay
- Author
-
Tony Mazzulli, Paul N. Levett, Todd F. Hatchette, M.J. Gill, J. Maregmen, K. Kadivar, Stephanie Lavoie, John Kim, R. Needle, Carmen L. Charlton, Kamran Kadkhoda, Richard Garceau, and D. Caswell
- Subjects
0301 basic medicine ,HIV Antigens ,030106 microbiology ,Human immunodeficiency virus (HIV) ,Antibodies, Heterophile ,HIV Infections ,HIV Antibodies ,medicine.disease_cause ,03 medical and health sciences ,Antigen ,Virology ,Siemens ADVIA Centaur ,medicine ,Fourth generation ,Humans ,Available Volume ,False Positive Reactions ,Immunoassay ,biology ,business.industry ,virus diseases ,Infectious Diseases ,HIV-2 ,biology.protein ,HIV-1 ,Antibody ,business - Abstract
Background False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or ‘combo’ assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. Objectives We sought to characterize these specimens and determine the effect of heterophilic interference. Study design Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Results Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94–678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Conclusions Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference.
- Published
- 2017
21. P2754Performance evaluation of the siemens advia centaur high sensitivity troponin i assay
- Author
-
L. Halik, H. Zhang, J. Balderson, C. Deflippi, J. Conklin, R. Gorman, J. Zhang, A. Chase, Y. Bahrainy, R. Payne, J. Ma, M. Gaylord, B. Plouffe, K. Yokoyama, and N. Ozgen
- Subjects
030213 general clinical medicine ,03 medical and health sciences ,0302 clinical medicine ,business.industry ,Siemens ADVIA Centaur ,High sensitivity troponin ,Medicine ,030204 cardiovascular system & hematology ,Cardiology and Cardiovascular Medicine ,business ,Nuclear medicine - Published
- 2017
- Full Text
- View/download PDF
22. Price of High-Throughput 25-Hydroxyvitamin D Immunoassays: Frequency of Inaccurate Results
- Author
-
Ashley R. Brady, Edward J. Yoon, Gary L. Horowitz, and Nicole V. Tolan
- Subjects
0301 basic medicine ,education.field_of_study ,medicine.diagnostic_test ,Chemistry ,Population ,Analytical chemistry ,General Medicine ,030204 cardiovascular system & hematology ,03 medical and health sciences ,Patient population ,030104 developmental biology ,0302 clinical medicine ,Method comparison ,Immunoassay ,Siemens ADVIA Centaur ,medicine ,education - Abstract
Background With a 10-year sustained increase in 25-hydroxyvitamin D [25(OH)D] testing, laboratories have swapped their LC-MS/MS methods for high-throughput automated immunoassays. Although it is generally well-known that immunoassays have poor recoveries for 25-hydroxyvitamin D2 [25(OH)D2], the frequency and extent to which this impacts total 25(OH)D have not been previously demonstrated. We evaluated 3 automated immunoassays against the first FDA-cleared CDC/NIST-traceable LC-MS/MS method. Methods Method comparison was performed for the Siemens ADVIA Centaur, Roche Elecsys Cobas, and Abbott Architect 25(OH)D immunoassay methods in real patient samples (n = 105). We calculated the mean bias in samples containing >20 ng/mL 25(OH)D2 and estimated the percent 25(OH)D2 cross-reactivities. We determined the prevalence of appreciable concentrations of 25(OH)D2 in our patient population through random sampling (n = 120) and projected the frequency of inaccurate 25(OH)D immunoassay results. Results Linear regression for 25(OH)D was y = 1.09x − 4.44 (Centaur), y = 0.84 + 0.43 (Cobas), and y = 0.83x − 0.48 (Architect). The mean biases of 25(OH)D concentrations were 5.6 (11.0) ng/mL (Centaur), −17.5 (7.2) ng/mL (Cobas), and −20.3 (9.8) ng/mL (Architect) in samples containing >20 ng/mL 25(OH)D2. The observed percent cross-reactivities for 25(OH)D2 were 115% (Centaur), 52% (Cobas), and 44% (Architect). We estimate that 8% of our population has >20 ng/mL 25(OH)D2, thereby compromising the accuracy of 25(OH)D results in >3000 samples annually. Conclusions We demonstrate that immunoassay manufacturer package inserts indicate much better recoveries of 25(OH)D2 than what is observed in unadulterated real patient samples. We estimate the frequency of inaccurate total 25(OH)D determination by these immunoassay methods to be largely dependent on the concentration of 25(OH)D2 in each sample.
- Published
- 2017
23. Interassay Comparison of the Tumor Markers CA125, CA15.3, and CA27.29
- Author
-
Andrew N. Hoofnagle, Dina N. Greene, Gabrielle N Winston-McPherson, Sheng-Ying Lo, and Anna E. Merrill
- Subjects
Oncology ,CA15-3 ,medicine.medical_specialty ,business.industry ,General Medicine ,030204 cardiovascular system & hematology ,medicine.disease ,Reference intervals ,03 medical and health sciences ,0302 clinical medicine ,Breast cancer ,030220 oncology & carcinogenesis ,Siemens ADVIA Centaur ,Internal medicine ,Multiple comparisons problem ,Immunology ,Medicine ,business ,Tumor marker - Abstract
Background Cancer antigens 125, 27.29, and 15-3 (CA125, CA27.29, and CA15-3) are markers of ovarian and breast cancer. Comparing tumor marker results across methods is challenging because of the lack of harmonization. Documenting comparability of results is important. Methods Siemens Advia Centaur CA125 and CA27.29 assays were compared to their corresponding Beckman Coulter DxI CA125 and CA15-3 assays. The interassay bias was determined and the manufacturer-recommended reference intervals were evaluated. Results The DxI CA125 assay demonstrated an overall positive 29% bias relative to the Centaur CA125 assay. The DxI CA15-3 assay demonstrated an overall negative 65% bias relative to the Centaur CA27.29 assay. For patients with multiple comparisons during the study period, the trend of results over time was similar across both sets of assays. Implementing the manufacturer-recommended reference interval for the DxI CA125 assay increased the abnormal flagging rate by 4.5%. In contrast, implementing the manufacturer-recommended reference interval for the DxI CA15-3 assay decreased the abnormal flagging rate by 13.0%. Conclusions The overall trends for the majority of patients were similar. Therefore, despite the overall biases, transitioning tumor marker assays should not affect clinical interpretation of results.
- Published
- 2017
24. Syphilis detection using the Siemens ADVIA Centaur Syphilis treponemal assay
- Author
-
Annemiek Letens-van Vliet, H. Roma Levy, and Ad Donkers
- Subjects
medicine.medical_specialty ,Clinical Biochemistry ,Automated immunoassay ,Biochemistry ,Pregnancy ,Syphilis testing ,Siemens ADVIA Centaur ,medicine ,Humans ,ADVIA Centaur ,Treponema pallidum ,Syphilis ,Treponema pallidum IgM ,Reverse algorithm ,Biochemistry, medical ,business.industry ,Biochemistry (medical) ,General Medicine ,medicine.disease ,Dermatology ,Syphilis Serodiagnosis ,Treponemal testing ,Immunology ,Performance evaluation ,Female ,business ,Algorithms - Abstract
Background Treponemal tests for detecting syphilis should be sufficiently sensitive and specific, especially when used as the first-line method in reverse-algorithm testing. We compared the Siemens ADVIA Centaur® Syphilis assay to 2 other commercial assays in use by the Star-MDC laboratory to evaluate its performance and usability. Methods Agreement between the Siemens ADVIA Centaur Syphilis assay, Siemens IMMULITE® 2000 Syphilis Screen, and Biokit bioelisa Syphilis 3.0 assay was evaluated using 1251 patient samples (50 from known positives, 701 from patients referred for syphilis testing, and 500 from pregnant women). Reactive samples (i.e., reactive according to at least two of the three treponemal methods) were further evaluated using Western blot IgG and IgM, and Venereal Disease Research Laboratory (VDRL) testing. Results Overall, positive and negative agreement was 100% between the Centaur and IMMULITE assays. In this study, overall agreement was 99.92% between either of the Siemens assays and the Biokit assay; positive agreement was 99%, and negative agreement was 100%. Overall, 0.88% (11/1251) of the samples were interpreted as positive/reactive based on the combined positive results by the ADVIA Centaur, IMMULITE 2000, and bioelisa assays; a positive Euroline anti- Treponema pallidum IgM blot; and a VDRL result of ≥ 1:8. In this study, no false-reactive samples were identified using this method. Conclusion The Centaur Syphilis assay performance is comparable to the other 2 commercial assays.
- Published
- 2014
- Full Text
- View/download PDF
25. A comprehensive validation of very early rule-out strategies for non-ST-segment elevation myocardial infarction in emergency departments: protocol for a multicentre prospective cohort study
- Author
-
Taku Iwami, Yoshimasa Murakami, Yoshimitsu Shimada, Ryota Okada, Masafumi Tada, Andrew R. Chapman, Hiroyuki Hayashi, Hideya Nagai, Hose Iwasaki, Hiroyasu Uzui, Naotsugu Iwakami, Ken-ichi Kano, Taketsune Kobuchi, Masaki Ando, Naoki Yamada, Hiroyuki Azuma, Takahisa Kawano, Sanae Kishimoto, Koji Maeno, Hideyuki Matano, Hiroshi Ishida, Nicholas L. Mills, Norio Watanabe, Hiroyuki Yoshida, Hiroshi Tada, Shigenobu Maeda, Toshi A. Furukawa, and Takahiko Aoyama
- Subjects
medicine.medical_specialty ,Acute coronary syndrome ,clinical impression ,030204 cardiovascular system & hematology ,Risk Assessment ,Time-to-Treatment ,03 medical and health sciences ,0302 clinical medicine ,Japan ,Predictive Value of Tests ,high sensitivity troponin ,Clinical Decision Rules ,Siemens ADVIA Centaur ,Protocol ,medicine ,Humans ,ST segment ,Prospective Studies ,030212 general & internal medicine ,Myocardial infarction ,Non-ST Elevated Myocardial Infarction ,Prospective cohort study ,prediction rule ,Protocol (science) ,business.industry ,Troponin I ,Ethics committee ,General Medicine ,medicine.disease ,University hospital ,myocardial infarction ,Early Diagnosis ,Emergency medicine ,Emergency Medicine ,Symptom Assessment ,Emergency Service, Hospital ,business ,Biomarkers - Abstract
IntroductionRecent advances in troponin sensitivity enabled early and accurate judgement of ruling-out myocardial infarction, especially non-ST elevation myocardial infarction (NSTEMI) in emergency departments (EDs) with development of various prediction-rules and high-sensitive-troponin-based strategies (hs-troponin). Reliance on clinical impression, however, is still common, and it remains unknown which of these strategies is superior. Therefore, our objective in this prospective cohort study is to comprehensively validate the diagnostic accuracy of clinical impression-based strategies, prediction-rules and hs-troponin-based strategies for ruling-out NSTEMIs.Methods and analysisIn total, 1500 consecutive adult patients with symptoms suggestive of acute coronary syndrome will be prospectively recruited from five EDs in two tertiary-level, two secondary-level community hospitals and one university hospital in Japan. The study has begun in July 2018, and recruitment period will be about 1 year. A board-certified emergency physician will complete standardised case report forms, and independently perform a clinical impression-based risk estimation of NSTEMI. Index strategies to be compared will include the clinical impression-based strategy; prediction rules and hs-troponin-based strategies for the following types of troponin (Roche Elecsys hs-troponin T; Abbott ARCHITECT hs-troponin I; Siemens ADVIA Centaur hs-troponin I; Siemens ADVIA Centaur sensitive-troponin I). The reference standard will be the composite of type 1 MI and cardiac death within 30 days after admission to the ED. Outcome measures will be negative predictive value, sensitivity and effectiveness, defined as the proportion of patients categorised as low risk for NSTEMI. We will also evaluate inter-rater reliability of the clinical impression-based risk estimation.Ethics and disseminationThe study is approved by the Ethics Committees of the Kyoto University Graduate School and Faculty of Medicine and of the five hospitals where we will recruit patients. We will disseminate the study results through conference presentations and peer-reviewed journals.
- Published
- 2019
- Full Text
- View/download PDF
26. Performance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 Total 25-OH Vitamin D assays
- Author
-
Eleftherios P. Diamandis, Adrien LeBlanc, Yu Chen, Heather Tarr, Andrea Božović, Lois Kinney, and Hilary Smith
- Subjects
Chromatography ,Chemistry ,business.industry ,Clinical Biochemistry ,Siemens ,Analytical chemistry ,General Medicine ,Reference Standards ,Signal-To-Noise Ratio ,Article ,Method comparison ,Limit of Detection ,Tandem Mass Spectrometry ,Analytics ,Siemens ADVIA Centaur ,Ergocalciferols ,Lc ms ms ,Linear Models ,Vitamin D and neurology ,Humans ,Total Vitamin D ,business ,Reference standards ,Blood Chemical Analysis ,Cholecalciferol - Abstract
To evaluate the newly developed Roche MODULAR Analytics E170 Total Vitamin D and the Siemens ADVIA Centaur Vitamin D Total assays.Assays were evaluated using the Clinical and Laboratory Standards Institute protocols. Split patient samples were compared with LC-MS/MS and DiaSorin LIAISON assays (n=79 including 15 specimens with detectable endogenous 25-OH vitamin D(2)). Assay accuracy was also evaluated using the Vitamin D External Quality Assessment Scheme (DEQAS) samples.The ADVIA Centaur and E170 assays demonstrated maximum total CVs of 14.1% and 5.9%, respectively. Both showed excellent linearity (R(2)0.99). The ADVIA Centaur assay demonstrated interference with bilirubin at 800 μmol/L, hemolysis at 1.25 g/L, and triglycerides at 2.8 mmol/L. Compared to LC-MS/MS, the ADVIA Centaur assay demonstrated a R(2) value of 0.893, average bias of -8.8%; the E170 assay an R(2) value of 0.872, average bias of 14.3% with underestimation of 25-OH vitamin D(2). Compared to the LIAISON assay, the ADVIA Centaur assay demonstrated an R(2) value of 0.781, average bias of -17.3%; the E170 assay an R(2) value of 0.823, average bias of 11.4%. The ADVIA Centaur and E170 assays demonstrated a biases of20% in 10/10 and 8/10 DEQAS samples, respectively.The ADVIA Centaur and E170 vitamin D assays demonstrated acceptable linearity, imprecision, and accuracy. The E170 assay demonstrated consistent underestimation of 25-OH vitamin D(2) levels. Compared with LC-MS/MS, the ADVIA Centaur assay demonstrated a higher R(2) value and a smaller average bias than the E170 assay.
- Published
- 2012
- Full Text
- View/download PDF
27. Performance evaluation of Siemens ADVIA Centaur® enhanced estradiol assay and a split sample comparison with liquid chromatography-tandem mass spectrometry
- Author
-
Lois Kinney, Yu Chen, and Steven J. Soldin
- Subjects
Immunoassay ,Chromatography ,Estradiol ,medicine.diagnostic_test ,Chemistry ,Clinical Biochemistry ,Siemens ,Reproducibility of Results ,General Medicine ,Mass spectrometry ,Split sample ,Method comparison ,Tandem Mass Spectrometry ,Liquid chromatography–mass spectrometry ,Siemens ADVIA Centaur ,medicine ,Humans ,Female ,ADVIA Centaur ,Chromatography, Liquid - Abstract
Objectives The objective of this study was to evaluate the newly developed Siemens ADVIA Centaur® enhanced Estradiol (eE2) assay and compare it with a well-established estradiol liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Design and methods The Siemens eE2 assay was evaluated using the Clinical and Laboratory Standards Institute evaluation protocols. Split patient samples were compared with the eE2 assay, the current ADVIA Centaur E2-6 Ill assay; and LC-MS/MS method by API5000 mass spectrometer. Results Within-run and total imprecision of the eE2 assay demonstrated coefficient of variations of 5.7%, 3.2%, 1.5%, and 10.4%, 7.3%, and 6.8%, at levels of 380, 752, and 2051 pmol/L, respectively. The method comparisons showed: eE2 = 0.903(E2-6 III) –16.2, R 2 = 0.938, average bias = − 12.3%; and eE2 = 0.946(LC-MS/MS) + 19.5, R 2 = 0.925, average bias: 0%. Conclusion The Siemens eE2 assay correlates well with LC-MS/MS. This method is reliable, and appropriate for routine clinical laboratory use.
- Published
- 2012
- Full Text
- View/download PDF
28. Standardization of assay methods reduces variability of total PSA measurements: an Irish study
- Author
-
Vivien E. Crowley, Ted McDermott, Ophelia Blake, Laure Marignol, Ronald Grainger, Thomas H. Lynch, and James C. Forde
- Subjects
medicine.medical_specialty ,Urology department ,business.industry ,Psa testing ,Urology ,Study Type ,Siemens ADVIA Centaur ,Medicine ,business ,Surgery ,Total psa - Abstract
Study Type – Diagnosis (quality control) Level of Evidence 2b What's known on the subject? and What does the study add? Today, numerous assays for PSA detection are available from various manufacturers. However, these various assays do not detect PSA equally and several studies have demonstrated variability between them. In order to harmonise PSA results and reduce the discrepancies, reference materials are available for assay calibration. We have demonstrated significantly variability between 6 different assay methods currently in use in 9 hospitals despite assay calibration. Variability in PSA values was reduced with the standardisation of the assay method in 4 hospitals. Our results highlight the dilemma of PSA assay variability and stress the need for nationwide standardisation of PSA testing. OBJECTIVE • To determine whether standardization of total prostate-specific antigen (tPSA) assay methods reduces variability in tPSA measurements. PATIENTS AND METHODS • Blood samples from 84 patients attending a single urology department were distributed across nine hospitals selected throughout Ireland for the independent determination of tPSA under the same conditions. • The selected hospitals collectively used six different assay methods for tPSA detection: Beckman Hybritech WHO Calibrated (used as reference method), Tosoh AIA 1800, Roche E170 (used in three hospitals), Abbott AxSYM, Immulite 2500 2nd Generation (used in two hospitals) and Siemens ADVIA Centaur. • The method of tPSA detection was next standardized in a subset of four hospitals using the same assay method and the measurements were repeated. • The difference in mean tPSA in the cohort across the hospitals tested was determined and the Bland–Altman test was used to assess the agreement between each test. Analysis was performed over both the full (0.5–30 µg/L, N= 84) and a narrow (3–7 µg/L, n= 25) tPSA range. RESULTS • The range and the mean tPSA of the full cohort were inflated across the eight test hospitals, when compared with the reference hospital. • The poorest agreement between assay methods was associated with a bias of 2.2 ± 2.4 µg/L. The variability in tPSA measurements between assay methods was inconsistent across the range of tPSA values tested and increased with increasing mean tPSA. • Agreement in reported tPSA was excellent after standardization of tPSA assay methods (bias
- Published
- 2012
- Full Text
- View/download PDF
29. Concordance, Variance, and Outliers in 4 Contemporary Cardiac Troponin Assays: Implications for Harmonization
- Author
-
Urs Wilgen, Carel J. Pretorius, Jacobus P.J. Ungerer, Louise Marquart, and Peter O'Rourke
- Subjects
Quality Control ,medicine.medical_specialty ,Percentile ,Pathology ,Analyte ,Cardiac troponin ,business.industry ,Concordance ,Troponin I ,Biochemistry (medical) ,Clinical Biochemistry ,Clinical Chemistry Tests ,medicine.disease ,Troponin complex ,Siemens ADVIA Centaur ,Internal medicine ,medicine ,Cardiology ,Humans ,Myocardial infarction ,business ,Biomarkers - Abstract
BACKGROUND Data to standardize and harmonize the differences between cardiac troponin assays are needed to support their universal status in diagnosis of myocardial infarction. We characterized the variation between methods, the comparability of the 99th-percentile cutoff thresholds, and the occurrence of outliers in 4 cardiac troponin assays. METHODS Cardiac troponin was measured in duplicate in 2358 patient samples on 4 platforms: Abbott Architect i2000SR, Beckman Coulter Access2, Roche Cobas e601, and Siemens ADVIA Centaur XP. RESULTS The observed total variances between the 3 cardiac troponin I (cTnI) methods and between the cTnI and cardiac troponin T (cTnT) methods were larger than expected from the analytical imprecision (3.0%–3.7%). The between-method variations of 26% between cTnI assays and 127% between cTnI and cTnT assays were the dominant contributors to total variances. The misclassification of results according to the 99th percentile was 3%–4% between cTnI assays and 15%–17% between cTnI and cTnT. The Roche cTnT assay identified 49% more samples as positive than the Abbott cTnI. Outliers between methods were detected in 1 patient (0.06%) with Abbott, 8 (0.45%) with Beckman Coulter, 10 (0.56%) with Roche, and 3 (0.17%) with Siemens. CONCLUSIONS The universal definition of myocardial infarction should not depend on the choice of analyte or analyzer, and the between- and within-method differences described here need to be considered in the application of cardiac troponin in this respect. The variation between methods that cannot be explained by analytical imprecision and the discordant classification of results according to the respective 99th percentiles should be addressed.
- Published
- 2012
- Full Text
- View/download PDF
30. Outliers as a Cause of False Cardiac Troponin Results: Investigating the Robustness of 4 Contemporary Assays
- Author
-
Louise Marquart, Urs Wilgen, Peter O'Rourke, Goce Dimeski, Shirley A. Tyack, Carel J. Pretorius, and Jacobus P.J. Ungerer
- Subjects
medicine.medical_specialty ,Cardiac troponin ,Clinical Biochemistry ,Troponin T ,Internal medicine ,Siemens ADVIA Centaur ,medicine ,Humans ,False Positive Reactions ,ADVIA Centaur ,Immunoassay ,biology ,business.industry ,Myocardium ,Troponin I ,Biochemistry (medical) ,Myocardium metabolism ,Data interpretation ,Troponin ,Surgery ,Data Interpretation, Statistical ,Outlier ,biology.protein ,Cardiology ,business ,Biomarkers - Abstract
BACKGROUND It is important that cardiac troponin be measured accurately with a robust method to limit false results with potentially adverse clinical outcomes. In this study, we characterized the robustness of 4 analytical platforms by measuring the outlier rate between duplicate results. METHODS We measured cardiac troponin concurrently in duplicate with 4 analyzers on 2391 samples. The outliers were detected from the difference between duplicate results and by calculating a z value: z = (result 1 − result 2) ÷ √(SD1est2 + SD2est2), with z > 3.48 identifying outliers with a probability of 0.0005. RESULTS The outlier rates were as follows: Abbott Architect i2000SR STAT Troponin-I, 0.10% (0.01%–0.19%); Beckman Coulter Access2 Enhanced AccuTnI, 0.44% (0.25%–0.63%); Roche Cobas e601 TroponinT hs, 0.06% (0.00%–0.13%); and Siemens ADVIA Centaur XP TnI-Ultra, 0.10% (0.01%–0.19%). The occurrence of outliers was higher than statistically expected on all platforms except the Cobas e601 (χ2 = 2.7; P = 0.10). A conservative approach with a constant 10% CV and z > 5.0 identified outliers with clear clinical impact and resulted in outlier rates of 0.11% (0.02%–0.20%) with the Architect i2000SR STAT Troponin-I, 0.36% (0.19%–0.53%) with the Access2 Enhanced AccuTnI, 0.02% (0.00%–0.06%) with the Cobas e601 TroponinT hs, and 0.06% (0.00%–0.13%) with the ADVIA Centaur XP TnI-Ultra. CONCLUSIONS Outliers occurred on all analytical platforms, at different rates. Clinicians should be made aware by their laboratory colleagues of the existence of outliers and the rate at which they occur.
- Published
- 2011
- Full Text
- View/download PDF
31. Performance evaluation of the new ADVIA® Centaur system cyclosporine assay (single-step extraction)
- Author
-
Jody Balko, Carolyn Chaffin, William Canfield, Robert W. Hardy, Julie Martel, H. Roma Levy, Frank H. Wians, Michael Oellerich, Steven J. Soldin, Minas Barbarakis, Damodara Rao Mendu, and Frank Streit
- Subjects
Adult ,Male ,030213 general clinical medicine ,Adolescent ,Clinical Biochemistry ,Analytical chemistry ,Single step ,Binding, Competitive ,030226 pharmacology & pharmacy ,Biochemistry ,Young Adult ,03 medical and health sciences ,0302 clinical medicine ,Reference Values ,Siemens ADVIA Centaur ,Fluorescence Polarization Immunoassay ,Humans ,ADVIA Centaur ,Aged ,Transplant type ,Aged, 80 and over ,Transplantation ,Cyclosporine assay ,business.industry ,Chemistry ,Biochemistry (medical) ,Relative bias ,General Medicine ,Middle Aged ,Cyclosporine ,Female ,Transplant patient ,Extraction methods ,Drug Monitoring ,Nuclear medicine ,business ,Immunosuppressive Agents - Abstract
Background Cyclosporine (CsA) monitoring is essential for transplant success. We report a performance study of the recently released, fully automated Siemens ADVIA Centaur ® CsA assay. Methods Whole blood samples from 248 transplant patients were prepared using a new 1-step extraction method. Performance evaluations vs. HPLC–tandem MS (LC-MS/MS), Abbott TDx and AxSYM assays were conducted according to CLSI EP5-A2 and EP9-A2 guidelines. Results The correlation coefficient for LC-MS/MS and ADVIA Centaur was ≥ 0.97 at each site, and for each transplant type. Regression analysis yielded y = 0.94 x + 19 for all sites: 95% CI = 0.91–0.96 (slope) and 10–28 (intercept). Absolute and relative bias was minimal for C0 and C2 sampling. Centaur vs. Abbott TDx and AxSYM assays: y = 0.72 x + 6, r = 0.98, 95% CI = 0.70–0.73 (slope), 3–9 (intercept); and y = 0.69 x + 18, r = 0.97, 95% CI = 0.67–0.71 (slope), 8–27(intercept). Within run CVs were 4.5%–7.1%, total CVs were 5.3%–7.7%. Conclusions The ADVIA Centaur assay compared favorably with LC-MS/MS and Abbott assays, displaying good correlation for all transplant types and methods.
- Published
- 2010
- Full Text
- View/download PDF
32. A long way to go for the harmonization of four immunoassays for carcinoembryonic antigen
- Author
-
Guigao Lin, Jinming Li, Hong Huo, Qingtao Wang, Yuhong Yue, and Kuo Zhang
- Subjects
0301 basic medicine ,Oncology ,medicine.medical_specialty ,Quality Assurance, Health Care ,Clinical Biochemistry ,Biochemistry ,World health ,03 medical and health sciences ,0302 clinical medicine ,Carcinoembryonic antigen ,Siemens ADVIA Centaur ,Internal medicine ,Neoplasms ,External quality assessment ,medicine ,Biomarkers, Tumor ,Humans ,Immunoassay ,medicine.diagnostic_test ,Reference preparation ,biology ,business.industry ,Biochemistry (medical) ,General Medicine ,Serum samples ,Carcinoembryonic Antigen ,030104 developmental biology ,030220 oncology & carcinogenesis ,Immunology ,biology.protein ,business - Abstract
Background Carcinoembryonic antigen (CEA) is one of the most widely used tumor markers worldwide. CEA immunoassays often yield different results. The objective of the present study was to investigate the current state of harmonization among CEA tests. Methods A total of 94 individual serum samples were divided into 3 subsets and measured in triplicate using 4 assays, Abbott Architect i2000SR, Beckman Access DXI800, Roche Cobas e601, and Siemens Advia Centaur XP. The standards from each manufacturer and the 1st International Reference Preparation (IRP) 73/601 of the World Health Organization were measured as unknowns in parallel with the patient samples using the 4 assays. The results of an external quality assessment (EQA) scheme for CEA were also analyzed. Results A perfect correlation was not observed between any 2 assays, and the values obtained using the 4 assays were different for the detection of 94 individual patient serum samples. No consistency was detected in the CEA results evaluated by various assays for EQA samples, individual patient samples, the standards from each manufacturer, and the WHO IRP 73/601. Conclusions Harmonization of the CEA results obtained using the 4 immunoassays has not yet been achieved.
- Published
- 2015
33. Multicenter comparison of automated procalcitonin immunoassays
- Author
-
Giuseppe Lippi, Massimo Locatelli, Andrea Motta, Tiziana Callegari, Giorgio Da Rin, Salvatore Pittalis, Mariella Dipalo, Vincenza Bianchi, Lorena Guido, Rosalia Aloe, and Gianmatteo Micca
- Subjects
medicine.medical_specialty ,Clinical Biochemistry ,Procalcitonin ,lcsh:Chemistry ,multicenter study, PCT, procalcitonin ,Bacterial infections ,Siemens ADVIA Centaur ,Sepsis ,medicine ,In patient ,ADVIA Centaur ,Immunoassay ,lcsh:R5-920 ,Radiological and Ultrasound Technology ,business.industry ,Serum samples ,Multicenter study ,Surgery ,lcsh:QD1-999 ,business ,Nuclear medicine ,lcsh:Medicine (General) ,PCT ,Research Article - Abstract
Objectives: A multicenter study to compare results of BRAHMS Kryptor PCT with those obtained using four BRAHMS-partnered procalcitonin (PCT) automated immunoassays (DiaSorin Liaison, BioMérieux Vidas, Roche Cobas E601 and Siemens Advia Centaur) and the Diazyme immunotubidimetric assay implemented on four clinical chemistry platforms (Abbott Architect c16000, Siemens Advia 2400, Roche Cobas C501 and Beckman Coulter AU5800). Design and methods: One hundred serum samples from in-patients with PCT values between 0.10 and 58.7 ng/mL were divided into aliquots and tested with the nine different reagents and analyzers. BRAHMS PCT Kryptor results were used as reference. Results: Compared to BRAHMS PCT Kryptor, significant differences in results were observed on Vidas, Advia Centaur, Architect, Cobas C501 and AU5800. However, the correlation coeffiecients (r) with BRAHMS PCT Kryptor were between 0.899 and 0.988. The mean bias was less than ±1.02 ng/mL, except for Vidas (2.70 ng/mL). The agreement at three clinically relevant cut-offs was optimal: between 83–98% at 0.50 ng/mL, 90–97% at 2.0 ng/mL, and 98% at 10 ng/mL. The comparison of Diazyme PCT across the four clinical chemistry analyzers yielded high correlation coefficients (r between 0.952 and 0.976), a mean bias less than ±0.9 ng/mL, acceptable agreement at 0.5 ng/mL (>82%), and high concordance at the 2.0 ng/mL (>97%) and 10 ng/mL (>98%) cut-offs. Conclusions: The methods and applications evaluated in this multicenter study are aligned with BRAHMS PCT Kryptor and can be used for predicting the risk of progression to systemic inflammation in patients with bacterial infections using the conventional PCT diagnostic thresholds. Keywords: Procalcitonin, Sepsis, Bacterial infections, Immunoassay, Multicenter study
- Published
- 2015
34. Evaluation of the new siemens ADVIA centaur testosterone II assay
- Author
-
Joseph Montalto, Alan McNeil, James C.G. Doery, Kay Weng Choy, and Nilika Wijeratne
- Subjects
03 medical and health sciences ,medicine.medical_specialty ,0302 clinical medicine ,Endocrinology ,business.industry ,Internal medicine ,Siemens ADVIA Centaur ,Medicine ,Testosterone (patch) ,030212 general & internal medicine ,030204 cardiovascular system & hematology ,business ,Pathology and Forensic Medicine - Published
- 2017
- Full Text
- View/download PDF
35. Blood Collection Tubes and Storage Temperature Should Be Evaluated when Using the Siemens ADVIA Centaur XP for Measuring 25-Hydroxyvitamin D
- Author
-
Huiling Fang, Weiyan Zhou, Songlin Yu, Ruiping Zhang, Qian Cheng, Liangyu Xia, Jianhua Han, Ling Qiu, Wei Su, and Xinqi Cheng
- Subjects
030213 general clinical medicine ,Physiology ,Surfactants ,Siemens ,Organic chemistry ,lcsh:Medicine ,030204 cardiovascular system & hematology ,Mass Spectrometry ,Analytical Chemistry ,Mathematical and Statistical Techniques ,Spectrum Analysis Techniques ,0302 clinical medicine ,Specimen Storage ,Tandem Mass Spectrometry ,Freezing ,Medicine and Health Sciences ,Vitamin D ,lcsh:Science ,Blood Specimen Collection ,Multidisciplinary ,Chromatographic Techniques ,Temperature ,Hematology ,Vitamins ,Body Fluids ,Physical sciences ,Chemistry ,Blood ,Liquid Chromatography-Tandem Mass Spectrometry ,Regression Analysis ,Anatomy ,Statistics (Mathematics) ,Research Article ,Materials science ,Materials Science ,Blood preservation ,Research and Analysis Methods ,Chemical compounds ,03 medical and health sciences ,Siemens ADVIA Centaur ,Organic compounds ,Humans ,Statistical Methods ,Immunoassays ,Materials by Attribute ,Analysis of Variance ,Chromatography ,lcsh:R ,Biology and Life Sciences ,Blood Preservation ,Storage and Handling ,Immunologic Techniques ,lcsh:Q ,Reagent Kits, Diagnostic ,Blood Collection Tube ,Mathematics ,Chromatography, Liquid - Abstract
A significant bias was found when using the Siemens ADVIA Centaur XP system for measurement of 25-hydroxyvitamin D (25OHD) with VACUETTE® tubes with Serum Clot Activator and Gel. Here, we examined whether other commonly used tubes or temperatures affected 25OHD results obtained with the Siemens ADVIA Centaur XP system. Serum was collected into five types of vacuum blood collection tubes from three manufacturers, and 25OHD was analyzed using the Siemens ADVIA Centaur XP system and liquid chromatography tandem mass spectrometry (LC-MS/MS) immediately or after storage at 4°C or -80°C for 48 h. Significantly higher 25OHD values were found when using the Siemens ADVIA Centaur XP system with VACUETTE® tubes with serum clot activator and gel and VACUETTE® tubes with clot activator but no gel compared with VACUETTE® tubes with no additives. The 25OHD values in all of these tubes were not significantly different from those obtained by LC-MS/MS. Moreover, after storage at -80°C for 48 h, the values obtained in IMPROVEVACUTER® tubes with serum clot activator and gel significantly increased, with a mean bias of 74.6% compared with the values before storage, on analysis with the Siemens ADVIA Centaur XP system. VACUETTE® tubes containing additives significantly affect the accuracy of 25OHD results obtained using the Siemens ADVIA Centaur XP system. Additionally, the composition of serum collected in IMPROVEVACUTER® tubes was affected by freezing, resulting in different measurements when using the Siemens 25OHD assay platform.
- Published
- 2016
- Full Text
- View/download PDF
36. Serial cardiac troponin differences measured on four contemporary analyzers: relative differences, actual differences and reference change values compared
- Author
-
Urs Wilgen, Carel J. Pretorius, and Jacobus P.J. Ungerer
- Subjects
Decision level ,Pathology ,medicine.medical_specialty ,Cardiac troponin ,business.industry ,Biochemistry (medical) ,Clinical Biochemistry ,Myocardial Infarction ,General Medicine ,Biochemistry ,Troponin ,Troponin complex ,Reference Values ,Biological variation ,Internal medicine ,Siemens ADVIA Centaur ,Troponin I ,Cardiology ,Medicine ,Humans ,business ,Blood Chemical Analysis - Abstract
Introduction The diagnosis of myocardial infarction is in part predicated on a rise and/or fall in cardiac troponin (cTn). z-Values incorporate analytical and biological variation to standardize serial differences: z = Δ / 2 S D Analytical 2 + 2 S D Biological 2 . We investigated the theoretical distributions of actual differences (Δ), relative differences (%Δ) and z-values and compared the agreement in classification of differences measured on four contemporary platforms. Methods cTn was measured in 575 sample pairs on the Abbott Architect cTnI, Beckman Coulter Access2 cTnI, Roche Cobas cTnT and Siemens ADVIA Centaur cTnI methods. Results Good agreement was obtained amongst all methods with a universal z-value cut-off (κ>0.79) and method specific fixed Δ cut-offs (κ>0.82) while suboptimal agreement was obtained between cTnI and cTnT with fixed %Δ cut-offs (κ Conclusion Fixed Δ cut-offs will perform well at low cTn concentrations while fixed %Δ cut-off values are predicted to perform poorly. z-Values are independent of the cTn concentration, present differences as a continuum of probability and a universal decision level can be used for all cTnI and cTnT methods.
- Published
- 2012
37. Sex-specific young adult reference ranges for sex hormone concentrations measured on the Siemens ADVIA Centaur/Geschlechtsspezifische Referenzbereiche für Sexualhormonkonzentrationen junger Erwachsener gemessen auf dem Siemens ADVIA Centaur
- Author
-
Robin Haring, Christin Spielhagen, Anke Hannemann, Matthias Nauck, and Nele Friedrich
- Subjects
medicine.medical_specialty ,biology ,business.industry ,Biochemistry (medical) ,Clinical Biochemistry ,Reference range ,Sex specific ,Medical Laboratory Technology ,Sex hormone-binding globulin ,Endocrinology ,Siemens ADVIA Centaur ,Internal medicine ,biology.protein ,Medicine ,Young adult ,business ,Testosterone - Abstract
The present study aims to determine reference ranges for sex hormone concentrations measured on the Siemens ADVIA CentaurThe study sample consisted of 1638 individuals (814 men and 824 women) aged 18–60 years with measured serum concentrations of total testosterone (TT), sex hormone-binding globulin (SHBG), and dehydroepiandrosterone sulfate (DHEAS). Values for free testosterone (free T) and free androgen index (FAI) were calculated. Sex- and age-specific (18 to Sex hormone reference ranges were determined across each single year of age separately for men (TT: 5.60–29.58 nmol/L, SHBG: 17.65–73.64 nmol/L, DHEAS: 0.96–4.43 mg/L, free T: 0.10–0.51 nmol/L, and FAI: 15.04–70.37 nmol/L) and women (TT: 0.77–2.85 nmol/L, SHBG: 27.06–262.76 nmol/L, DHEAS: 0.50–3.15 mg/L, free T: 0.005–0.05 nmol/L, and FAI: 0.51–8.30 nmol/L), respectively.
- Published
- 2012
- Full Text
- View/download PDF
38. Age-dependent reference intervals for measured bioavailable testosterone on the Siemens Advia Centaur: ethnicity-specific values not necessary for South Asians
- Author
-
Amanda C. Zimmerman, Daniel T. Holmes, Kevin A. Buhr, and Scott A. Lear
- Subjects
Adult ,Male ,medicine.medical_specialty ,South asia ,Clinical Biochemistry ,Physiology ,Age dependent ,Cohort Studies ,Sex hormone-binding globulin ,Age Distribution ,Asian People ,Reference Values ,Internal medicine ,Siemens ADVIA Centaur ,medicine ,Humans ,Testosterone ,Aged ,biology ,Chemistry ,Testosterone (patch) ,General Medicine ,Middle Aged ,Reference Standards ,Reference intervals ,Endocrinology ,Cohort ,Bioavailable Testosterone ,biology.protein - Abstract
Objectives To determine reference intervals for bioavailable testosterone for the Siemens Centaur analyzer and to assess the need for ethnicity-specific ranges for total testosterone and/or bioavailable testosterone in South Asians. Design and methods Testosterone was measured before and after ammonium sulphate precipitation on specimens collected from a small cohort of healthy male South Asians and Europeans. Results Inter-ethnicity differences in BioT and TT were not significant. Age-specific BioT reference intervals are reported. Conclusions Ethnicity-specific TT and BioT reference intervals for South Asians do not appear necessary.
- Published
- 2009
39. 4th generation HIV testing false positivity by Siemens ADVIA Centaur® XP: a retrospective study
- Author
-
Burak Bahar
- Subjects
Pediatrics ,medicine.medical_specialty ,business.industry ,Biochemistry (medical) ,Clinical Biochemistry ,Retrospective cohort study ,Hiv testing ,False positivity ,Biochemistry ,Siemens ADVIA Centaur ,Immunology ,medicine ,business ,Molecular Biology - Published
- 2012
- Full Text
- View/download PDF
40. P2.037 Multicenter Evaluation of Three Novel 4ThGeneration HIV Ag/Ab Combo Assays: Abbott Architect, Roche HIV Combi and Siemens Advia Centaur: Abstract P2.037 Table 1
- Author
-
A Poirier, J Vincelette, E Frost, C Béliveau, F Doualla-Bell, D Phaneuf, Bouchra Serhir, M Bergevin, R Sanfaçon, and Cécile Tremblay
- Subjects
Oncology ,medicine.medical_specialty ,business.industry ,Human immunodeficiency virus (HIV) ,Acute infection ,HIV screening ,Dermatology ,medicine.disease_cause ,Screening HIV ,Infectious Diseases ,Siemens ADVIA Centaur ,Internal medicine ,Immunology ,medicine ,ADVIA Centaur ,business - Abstract
Background Currently, 24 out of 39 laboratories in Quebec use the AxSYM HIV Ag/Ab Combo for HIV screening. This kit will be discontinued December 2013 and three novel 4th generation screening HIV assays (Architect, Roche Elecsys HIV Combi and ADVIA CENTAUR), approved by Health Canada, represent the alternative to AxSYM. Objective and Methods: To investigate the performance of these 3 novel screening HIV Combo assays, in 6 clinical sites from Quebec. A total of 150 samples from patients with documented acute infection, a panel of 25 Seracare HIV-1 specimens, 3 quality control specimens (HIV-1.2 Ab POS, p24Ag POS, HIV-1.2 NEG), and 5577 sera from routine diagnostic patients were tested. Results Sensitivity assessment- The 3 novel combos demonstrated comparable 100% sensitivity. Confirmed positive samples on the Architect and Roche Elecsys presented much greater S/CO values than AxSYM. Specificity assessment- Each novel combo was compared separately to the AxSYM. Discordant results were confirmed using supplemental confirmatory assays. The specificity of Architect was evaluated using 1099 specimens: 1095/1099 were non reactive, 3/1099 were reactive and 1/1099 was discordant. For Roche Combo, 3282 specimens were tested: 3222/3282 were non reactive, 41/3282 were reactive, and 19/3282 were discordant. The Advia Centaur was evaluated using 1196 specimens, 1177/1196 were non reactive, 12/1196 were reactive and 7 were discordant. Amongst the 66 specimens that were reactive with novel and AxSYM combos, 52 (79%) were confirmed positive. All discordant results were confirmed negative. The 5494 specimens that were negative with both kits (novel and AxSYM) demonstrated lower S/CO values on Architect and Roche than on AxSym. Conclusions The 3 novel HIV Ag/Ab Combo demonstrated good performance (sensitivity, specificity and concordance) with better segregation of positive and negative samples than AxSYM. All 3 kits represent a good alternative to the AxSYM.
- Published
- 2013
- Full Text
- View/download PDF
41. Performance evaluation of four 25-hydroxyvitamin D assays to measure 25-hydroxyvitamin D2
- Author
-
Victoria Shalhoub, Ryan Spears, James Freeman, Paul Sibley, and Kimberly Wilson
- Subjects
Adult ,Male ,Clinical Biochemistry ,Analytical chemistry ,Isotope dilution ,25(OH)D2 ,Young Adult ,25(OH)D3 ,Tandem Mass Spectrometry ,Liquid chromatography–mass spectrometry ,Siemens ADVIA Centaur ,25 Hydroxyvitamin D ,Vitamin D and neurology ,Humans ,Vitamin D ,ID-LC-MS/MS ,Aged ,25-Hydroxyvitamin D 2 ,Immunoassay ,Chromatography ,Vitamin d supplementation ,VDSCP ,25(OH)D ,Chemistry ,Reproducibility of Results ,General Medicine ,Middle Aged ,Reference Standards ,Serum samples ,Vitamin D total assay ,Dietary Supplements ,Oral vitamin ,Biological Assay ,Female ,Chromatography, Liquid ,Blood drawing - Abstract
Objectives The ability of current immunoassays to accurately measure equimolar amounts of 25(OH)D 2 and 25(OH)D 3 has been recently questioned. This study determined serum 25(OH)D 2 , 25(OH)D 3 and total serum 25(OH)D concentrations in healthy vitamin D 2 -supplemented subjects by isotope dilution liquid chromatography mass spectrometry (ID-LC-MS/MS); and, evaluated the ability of the Siemens, DiaSorin, Roche, and Abbott Vitamin D Total assays to monitor total serum 25(OH)D concentrations compared to an ID-LC-MS/MS method traceable to the National Institute of Standards and Technology (NIST), and that has achieved certification from the Centers for Disease Control and Prevention (CDC) Vitamin D Standardization Certification Program (VDSCP). Design and methods Twenty (20) healthy adults, with no history of prior vitamin D supplementation were administered oral vitamin D 2 (2400 IU/day for 6 months). Serum samples (140) from baseline and monthly blood draws were tested. Results After one month, the mean serum 25(OH)D 2 concentrations rose from 0.8 to 43.6 nmol/L, whereas 25(OH)D 3 concentrations declined from 84.0 to 63.4 nmol/L; total serum 25(OH)D concentrations rose from 86.6 to 107.0 nmol/L. The overall mean bias to ID-LC-MS/MS was − 7.1% for the Siemens ADVIA Centaur assay, − 15.3% for the DiaSorin LIAISON assay; − 8.4% for the Roche ELECSYS assay and − 16.3% for the Abbott ARCHITECT assay. Correlation coefficients (r) were 0.94, 0.79, 0.74, and 0.73; the mean bias for baseline [25(OH) D 3 -containing] versus six-month [25(OH)D 2 - and 25(OH)D 3 -containing] samples was − 13.4% and − 5.7%; − 3.5% and 20.3%, 9.6% and − 12.1%, and 0.2% and − 17.8%, respectively. Conclusions The bias results obtained for the Siemens ADVIA Centaur assay and Roche ELECSYS assay were slightly lower than those for the DiaSorin LIAISON assay and the Abbott ARCHITECT assay, but all 25(OH)D assays demonstrated acceptable performance.
- Full Text
- View/download PDF
42. [Untitled]
- Subjects
Lateral flow test ,Multidisciplinary ,Chromatography ,Cardiac troponin ,Plasma samples ,Method comparison ,business.industry ,Siemens ADVIA Centaur ,Point-of-care testing ,Troponin I ,Medicine ,In patient ,business - Abstract
Measurement of cardiac troponin I (cTnI) should be feasible for point-of-care testing (POCT) to diagnose acute myocardial infarction (AMI). Lateral flow immunoassays (LFIAs) have been long implemented in POCT and clinical settings. However, sensitivity, matrix effect and quantitation in lateral flow immunoassays (LFIAs) have been major limiting factors. The performance of LFIAs can be improved with upconverting nanoparticle (UCNP) reporters. Here we report a new methodological approach to quantify cTnI using UCNP-LFIA technology with minimized plasma interference. The performance of the developed UCNP-LFIA was evaluated using clinical plasma samples (n = 262). The developed UCNP-LFIA was compared to two reference assays, the Siemens Advia Centaur assay and an in-house well-based cTnI assay. By introducing an anti-IgM scrub line and dried EDTA in the LFIA strip, the detection of cTnI in plasma samples was fully recovered. The UCNP-LFIA was able to quantify cTnI concentrations in patient samples within the range of 30–10,000 ng/L. The LoB and LoD of the UCNP-LFIA were 8.4 ng/L and 30 ng/L. The method comparisons showed good correlation (Spearman’s correlation 0.956 and 0.949, p