1. Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
- Author
-
Yuqing WU, Hong ZHOU, Zhijie ZHANG, Zhiquan RONG, Xuemei LI, Zhe SONG, Shuhong ZHAO, Zhongsi YANG, Qun LIU, Lin ZHU, Xiaojuan FAN, Shuli SUN, Wei ZHANG, Jinyu HAN, Haiyan HUANG, Guangcai LIU, Ping CHEN, Xianwu AN, Hui ZHANG, Junxia REN, Xuejing LI, Chenxi YANG, Bo ZHOU, Hui YE, Mingming QIAO, Hua SHEN, Dunzhu GONGJUE, and Yunlong ZHUANG
- Subjects
blood bank ,blood donation service ,blood component preparation ,blood supply ,quality monitoring indicator system ,comparison ,Diseases of the blood and blood-forming organs ,RC633-647.5 ,Medicine - Abstract
Objective To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. Methods A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. Results The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P
- Published
- 2024
- Full Text
- View/download PDF