8 results on '"Schreiberová, Z."'
Search Results
2. OČNÍ KOMPLIKACE DIABETES MELLITUS V OBDOBÍ GRAVIDITY - KAZUISTIKA.
- Author
-
Schreiberová, Z., Chrapek, O., and Šimičák, J.
- Published
- 2020
3. Evaluation of Clinical Results of Implantation of Toric Intraocular Lenses Including their Rotational Stability.
- Author
-
Pašková B, Marešová K, Schreiberová Z, Malušková M, and Karhanová M
- Subjects
- Male, Female, Humans, Aged, Lens Implantation, Intraocular, Retrospective Studies, Refraction, Ocular, Astigmatism surgery, Phacoemulsification methods, Lenses, Intraocular, Cataract, Corneal Diseases
- Abstract
Purpose: The aim of the study was to evaluate the clinical results of the implantation of the toric intraocular lens Acrysof IQ Toric SN6AT3_8 (Alcon Laboratories, Inc., Fort Worth, TX, USA), including an evaluation of its rotational stability., Material and Methods: 30 eyes of 16 patients (4 males, 12 females; mean age 68 years) with regular corneal astigmatism ranging from -1.5 to -4.0 Dcyl were included in this retrospective study. All the patients underwent uncomplicated cataract surgery with the implantation of a toric intraocular lens (TIOL) at the Department of Ophthalmology of the Faculty of Medicine and Dentistry of Palacký University in Olomouc and University Hospital Olomouc during the course of 2020. Follow-up examinations were performed 3-6 months after cataract surgery. We monitored the resulting uncorrected distance visual acuity (UDVA), postoperative refraction, rotational stability of the implanted lens and subjective patient satisfaction., Results: mean preoperative corneal astigmatism was -2.41 ±0.67 Dcyl. UDVA improved from a mean value of 0.45 ±0.25 (expressed in decimal Snellen optotype values) to 0.91 ±0.16. The spherical equivalent value of 0.41 ±2.92 improved to -0.11 ±0.27 postoperatively. The mean deviation from the planned axis was 4.87 ±4.75. Subjective satisfaction was rated by patients on a scale of 1-5, with a mean score of 1.5., Conclusion: TIOL implantation is a safe and effective solution for patients with corneal astigmatism and cataract. Our results demonstrate improved UDVA, rotational stability of the TIOL and subjective patient satisfaction with the outcome of the surgery.
- Published
- 2024
- Full Text
- View/download PDF
4. The Impact of the COVID-19 Pandemic on the Quality of Examination in Eye Clinics in the Czech Republic - Questionnaire Study.
- Author
-
Karhanová M, Cyžová Z, Schreiberová Z, Kalitová J, Mlčák P, Kalábová S, Mlčáková E, and Marešová K
- Subjects
- Male, Humans, Female, SARS-CoV-2, Pandemics prevention & control, Czech Republic, Surveys and Questionnaires, COVID-19 epidemiology, COVID-19 prevention & control
- Abstract
Purpose: The aim of the study was to map the behavior of ophthalmologists regarding protective equipment during the COVID-19 pandemic (coronavirus disease 2019), both during the time of the mandatory restrictive measures and after their relaxation. Another aim was to evaluate the awareness of ophthalmologists in the Czech Republic about the possible impact of nose and mouth protective measures (masks, respirators) on the quality of eye examinations, especially on the results of standard automated perimetry (SAP) and intraocular pressure (IOP) measurement., Materials and Methods: As part of two professional ophthalmological events in the Czech Republic, which took place in 2022, we obtained and evaluated data from the ophthalmologists in attendance using a questionnaire. We evaluated demographic parameters, frequency of use and type of nose and mouth protective equipment and their influence on the quality of ophthalmological examination as well as the awareness of ophthalmologists about their possible influence on the outcome of SAP and IOP measurements., Results: We obtained data from a total of 212 respondents (148 women, 44 men, in 20 cases gender was not stated). In 91.5% of cases, ophthalmologists agreed that the use of respirators and masks makes ophthalmological examination more difficult. The most common problems were eyepiece fogging (85.8%), examination lens fogging (85.8%), and lens fogging when spectacles correction was prescribed (79.2%). The respondents most often combated these problems either by completely removing the respirator (24.1%) or at least by pulling it under the nose (39.2%). At the time when the measures were relaxed, significantly more men did not use any nose and mouth protection at all during ophthalmological examinations (15.8% of men vs. 4.2% of women; p = 0.032). An alarming finding was the fact that 35.6% of respondents did not know whatsoever whether the nurse was performing a perimetry examination on a patient with a respirator/mask or without protective equipment, i.e. they were not aware whatsoever of the possible formation of artifacts. Only 21.2% of respondents were aware of the possible difficulties of measuring IOP while wearing a respirator, while 59.9% of respondents were not aware of this risk (39.6% had never considered this problem, 20.3% of respondents were convinced that a respirator could not have an effect on the measurement of IOP)., Conclusion: The use of nose and mouth protective equipment clearly affects the ophthalmological examination and makes it more difficult. Although ophthalmologists belong to a group at high risk for the possible transmission of infection in the performance of their profession, they often removed nose and mouth protection in an effort to eliminate fogging of eyepieces and examination lenses. The awareness of ophthalmologists regarding the possible influence on the results of SAP and IOP measurement by wearing a respirator was low in our questionnaire survey. It is therefore advisable to discuss this issue more widely and warn doctors about these risks.
- Published
- 2024
- Full Text
- View/download PDF
5. ULTRASOUND EXAMINATION OF THE ORBIT IN PATIENTS WITH THYROIDASSOCIATED ORBITOPATHY - EXAMINATION GUIDE AND RECOMMENDATIONS FOR EVERYDAY PRACTICE. A REVIEW.
- Author
-
Karhanová M, Čivrný J, Kalitová J, Schovánek J, Malušková M, Hrevuš M, and Schreiberová Z
- Subjects
- Humans, Oculomotor Muscles, Ultrasonography, Graves Ophthalmopathy
- Abstract
The purpose of this study is to present the possibilities and benefits of ultrasonography (US) of the orbit in the diagnosis and treatment of thyroidassociated orbitopathy (TAO). Methods: US examination of the orbit is an essential addition to clinical and laboratory examination in TAO patients. Nevertheless, it is often neglected in clinical practice or indicated with delay. Based on previously published studies and our experience with the diagnosis and treatment of TAO patients, we aim to highlight the clear benefit of US examination of the orbit and oculomotor muscles, not only for correct TAO diagnosis but also in the monitoring of the disease over time. However, knowledge of the drawbacks and limitations of this method is also essential, as we shall point out. It is always necessary to remember that US examination must be evaluated in connection with the clinical findings. A detailed recommendation for US examination of the extraocular muscles and the orbit based on our experiences with diagnosing and treating TAO patients in daily practice is also included. Conclusion: According to our experience, US examination of the orbit is an excellent and irreplaceable tool for timely TAO diagnosis and further disease monitoring. However, considerable examiner experience and detailed knowledge of the clinical and ultrasound manifestations of TAO are essential.
- Published
- 2024
6. Computed tomography and magnetic resonance imaging of the orbit in the diagnosis and treatment of thyroid-associated orbitopathy - experience from practice. A Review.
- Author
-
Karhanová M, Čivrný J, Kalitová J, Schovánek J, Pašková B, Schreiberová Z, and Hübnerová P
- Subjects
- Humans, Orbit diagnostic imaging, Orbit pathology, Oculomotor Muscles, Magnetic Resonance Imaging, Tomography, X-Ray Computed, Graves Ophthalmopathy diagnostic imaging, Graves Ophthalmopathy therapy
- Abstract
The purpose is to acquaint readers with the contribution of imaging methods (IMs) of the orbit, specifically computed tomography (CT) and magnetic resonance imaging (MRI), in the diagnosis of thyroid-associated orbitopathy (TAO). Methods: IMs of the orbit are an indispensable accessory in the clinical and laboratory examination of TAO patients. The most frequently used and probably most accessible method is an ultrasound examination of the orbit (US), which, however, has a number of limitations. Other methods are CT and MRI. Based on the published knowledge implemented in our practice and several years of experience with the diagnosis and treatment of TAO patients, we would like to point out the benefits of CT and MRI in the given indications: visualisation of the extraocular muscles, assessment of disease activity, diagnosis of dysthyroid optic neuropathy and differential diagnosis of other pathologies in the orbit. Our recommendation for an ideal MRI protocol for disease activity evaluation is also included. Conclusion: IMs play an irreplaceable role not only in the early diagnosis of TAO, but also in the monitoring of the disease and the response to the applied treatment. When choosing a suitable IM for this diagnosis, a number of factors must always be taken into account; not only availability, cost and burden for the patient, but especially the sensitivity and specificity of the given method for the diagnosis of TAO.
- Published
- 2023
- Full Text
- View/download PDF
7. Retinal oxygen saturation in monoclonal gammopathies patients: A pilot study.
- Author
-
Hübnerová P, Karhanová M, Krhovská P, Minařík J, Mlčák P, Pašková B, Schreiberová Z, Šínová I, Zapletalová J, and Šín M
- Subjects
- Male, Humans, Female, Middle Aged, Aged, Pilot Projects, Retina, Retinal Vessels, Oxygen, Oximetry methods, Oxygen Saturation, Paraproteinemias diagnosis
- Abstract
Purpose: The aim of this pilot study was to assess oxygen saturation in retinal blood vessels in patients with monoclonal gammopathies (MGs)., Methods: Thirty-one patients with MGs (11 women and 20 men, mean age 65.9 ± 8.9 years) were enrolled during 2016-2020. The patients were diagnosed at the Haemato-Oncology Department and subsequently examined at the Ophthalmology Department before initiating systemic therapy. All patients were subjected to automatic retinal oximetry (Oxymap ehf.) and had their fundus photographed (Topcon TRC-50DX retinal camera). We assessed the association between retinal oxygen saturation (SatO
2 ) - arterial SatO2 , venous SatO2 and arterio-venous (AV) difference-and MGs parameters: serum monoclonal immunoglobulin (M-protein) level and serum immunoglobulin-free light chains (FLC kappa and lambda), total protein, serum viscosity, haemoglobin, albumin, lactate dehydrogenase, C-reactive protein, creatinine and serum calcium level. Hyperviscosity-related retinopathy was also evaluated., Results: Statistical analysis showed a significant positive correlation (r = 0.462; p = 0.009) between the AV difference and the haemoglobin level. A significant, medium strong negative correlation was found between the AV difference and the serum levels of the monoclonal light lambda chains (r = -0.450; p = 0.011). Contrary to expectations, no statistically significant correlation was found between retinal oxygen saturation and the total protein or viscosity., Conclusion: This study found correlation between retinal oxygen saturation and certain parameters in the blood of patients with MGs. Increasing levels of monoclonal immunoglobulin seem to reduce oxygen absorption in retinal arterioles, resulting in a lower AV difference, particularly in patients with a high free light chain level., (© 2022 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.)- Published
- 2023
- Full Text
- View/download PDF
8. OCULAR COMPLICATIONS OF DIABETES MELLITUS IN PREGNANCY - CASE REPORT.
- Author
-
Schreiberová Z, Chrapek O, and Šimičák J
- Subjects
- Female, Humans, Laser Coagulation, Pregnancy, Retina, Diabetes Mellitus, Type 1 complications, Diabetic Retinopathy complications, Diabetic Retinopathy diagnosis, Diabetic Retinopathy surgery, Macular Edema
- Abstract
Pregnancy is associated with increased risk of progression of diabetic retinopathy (DR), the greatest risk of worsening occurs during the second trimester of pregnancy and persists as long as one year after the childbirth. The risk factors include duration of the diabetes, insufficient metabolic control, severity of DR at the time of conception and presence of coexisting vascular disease, such as arterial hypertension, and pregnancy itself. The recommendations for retinopathy screening in pregnancy vary significantly. A dilated fundus exam should be done in the beginning of pregnancy, the next follow-up throughout pregnancy depends on the severity of ocular findings. The cooperation of multi-disciplinary team consisting of ophthalmologist, obstetrition and endocrinologist is essential to provide the best health care. The authors present a case report of a pregnant woman with type 1 diabetes mellitus (DM), who had a progression of DR and diabetic macular edema (DME) in both eyes during pregnancy. She has had DM for 24 years and has been treated with insulin. The patient was examined at the 23rd week of the second pregnancy (first pregnancy was terminated because of missed miscarriage). The diagnosis of advanced proliferative DR and advanced DME in both eyes was made so we performed panretinal laser photocoagulation of the retina of both eyes. Despite that the ocular findings got worse and we found vitreous haemorrhage in the left eye. We performed pars plana vitrectomy (PPV) of the left eye at the 28th week of pregnancy, nevertheless the DME got worse in both eyes, so we recommended to terminate the pregnancy at the 31st week because of the risk of loss of vision. The visual acuity of the left eye improved, but suddenly there was vitreous haemorrhage in the right eye after the delivery. We indicated PPV of the right eye, the outcome of the surgery was satisfying. We still take care about this patient.
- Published
- 2020
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.