1. Comparison between invasive and noninvasive methods to estimate subendocardial oxygen supply and demand imbalance
- Author
-
Salvi, P, Baldi, C, Scalise, F, Grillo, A, Salvi, L, Tan, I, De Censi, L, Sorropago, A, Moretti, F, Sorropago, G, Gao, L, Rovina, M, Simon, G, Fabris, B, Carretta, R, Avolio, A, Parati, G, Salvi P., Baldi C., Scalise F., Grillo A., Salvi L., Tan I., De Censi L., Sorropago A., Moretti F., Sorropago G., Gao L., Rovina M., Simon G., Fabris B., Carretta R., Avolio A. P., Parati G., Salvi, P, Baldi, C, Scalise, F, Grillo, A, Salvi, L, Tan, I, De Censi, L, Sorropago, A, Moretti, F, Sorropago, G, Gao, L, Rovina, M, Simon, G, Fabris, B, Carretta, R, Avolio, A, Parati, G, Salvi P., Baldi C., Scalise F., Grillo A., Salvi L., Tan I., De Censi L., Sorropago A., Moretti F., Sorropago G., Gao L., Rovina M., Simon G., Fabris B., Carretta R., Avolio A. P., and Parati G.
- Abstract
BACKGROUND: Estimation of the balance between subendocardial oxygen supply and demand could be a useful parameter to assess the risk of myocardial ischemia. Evaluation of the subendocardial viability ratio (SEVR, also known as Buckberg index) by invasive recording of left ventricular and aortic pressure curves represents a valid method to estimate the degree of myocardial perfusion relative to left ventricular workload. However, routine clinical use of this parameter requires its noninvasive estimation and the demonstration of its reliability. METHODS AND RESULTS: Arterial applanation tonometry allows a noninvasive estimation of SEVR as the ratio of the areas directly beneath the central aortic pressure curves obtained during diastole (myocardial oxygen supply) and during systole (myocardial oxygen demand). However, this “traditional” method does not account for the intra-ventricular diastolic pressure and proper allocation to systole and diastole of left ventricular isometric contraction and relaxation, respectively, resulting in an overestimation of the SEVR values. These issues are considered in the novel method for SEVR assessment tested in this study. SEVR values estimated with carotid tonometry by "traditional” and "new” method were compared with those evaluated invasively by cardiac catheterization. The “traditional” method provided significantly higher SEVR values than the reference invasive SEVR: average of differences±SD= 44±11% (limits of agreement: 23% – 65%). The noninvasive “new” method showed a much better agreement with the invasive determination of SEVR: average of differences±SD= 0±8% (limits of agreement:-15% to 16%). CONCLUSIONS: Carotid applanation tonometry provides valid noninvasive SEVR values only when all the main factors determining myocardial supply and demand flow are considered.
- Published
- 2021