1. Inter-rater and intra-rater reliability of sonographic median nerve and wrist measurements
- Author
-
Consuelo B Gonzalez-Suarez, Lorraine D Buenavente, Ronald Christopher A Cua, Maria Belinda C Fidel, Jan-Tyrone C Cabrera, and Carina Fatima G Regala
- Subjects
Carpal tunnel ,median nerve ,ultrasonographic measurements ,Medical technology ,R855-855.5 - Abstract
Background: Electrophysiologic studies have been considered the “gold standard” in diagnosing carpal tunnel syndrome (CTS); however, reports of false-negative results, as well as discomfort for the patient during the procedure has paved the use of ultrasound, being a painless and cost-efficient tool, as an alternative means for its diagnosis. Various ultrasound parameters assessing the median nerve and wrist dimensions have been described, but description of landmarks to assess these in a reliable manner has been lacking. Methodology: A systematic search of different databases yielded data regarding ultrasound parameters for CTS diagnosis, the landmarks used, and presence of reliability testing. Based on this, three sonologists discussed the external and sonographic landmarks that will be used in measuring the median nerve measurements, bowing of the flexor retinaculum and the carpal tunnel dimensions. A pilot test with two consecutive healthy participants using the discussed ultrasound parameters was carried out, and results were subjected to inter- and intra-rater reliability testing. Modifications were accordingly made on the acquisition of ultrasound image using external landmarks. The reliability testing proper was done with ten consecutive healthy participants. Results: Based on the systematic review and the pilot study, external landmarks were used to locate the median nerve in the forearm, carpal tunnel inlet and outlet. For the forearm measurement, it was taken 10 cm proximal from the distal palmar crease. The distal palmar crease was the external landmark used for the carpal tunnel inlet, while for the carpal tunnel outlet; it was measured 1 cm distal to the distal palmar crease. Instead of using the inner edge of the hook of hamate and trapezium, the apices of these bones were used as the landmarks in measuring the carpal tunnel outlet dimensions. There was excellent intra-rater reliability (mid-forearm, carpal tunnel inlet and outlet) except for the following: cross-sectional area (CSA) of the median nerve at the carpal tunnel inlet and outlet; and bowing of the flexor retinaculum. All the parameters had an excellent inter-rater reliability measured at the three levels (intraclass correlation [ICC]: Of 0.77–0.99) except for CSA of the median nerve at the levels of the forearm (fair-to-good with ICC of 0.71) and the carpal tunnel inlet (fair-to-good reliability of ICC: 0.43). Conclusion: There was an improved inter- and intra-rater reliability when external landmarks were used instead of sonographic landmarks.
- Published
- 2018
- Full Text
- View/download PDF