14 results on '"Roessler FC"'
Search Results
2. Erste Untersuchungen mit einem selbstoptimierenden Computermodel zur individuellen Simulation der zerebralen Hämodynamik
- Author
-
Roessler, FC, primary, Metzler, V, additional, Grebe, R, additional, and Siegel, G, additional
- Published
- 2007
- Full Text
- View/download PDF
3. Case Report: Take a Second Look: Covid-19 Vaccination-Related Cerebral Venous Thrombosis and Thrombotic Thrombocytopenia Syndrome.
- Author
-
Braun T, Viard M, Juenemann M, Struffert T, Schwarm F, Huttner HB, and Roessler FC
- Abstract
We present two cases of ChAdOx1 nCov-19 (AstraZeneca)-associated thrombotic thrombocytopenia syndrome (TTS) and cerebral venous sinus thrombosis (CVST). At the time of emergency room presentation due to persistent headache, blood serum levels revealed reduced platelet counts. Yet, 1 or 4 days after the onset of the symptom, the first MR-angiography provided no evidence of CVST. Follow-up imaging, performed upon headache refractory to nonsteroidal pain medication verified CVST 2-10 days after initial negative MRI. Both the patients received combined treatment with intravenous immunoglobulins and parenteral anticoagulation leading to an increase of platelet concentration in both the individuals and resolution of the occluded cerebral sinus in one patient., Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (Copyright © 2021 Braun, Viard, Juenemann, Struffert, Schwarm, Huttner and Roessler.)
- Published
- 2021
- Full Text
- View/download PDF
4. Development and reliability of the histological THROMBEX-classification rule for thrombotic emboli of acute ischemic stroke patients.
- Author
-
Ribbat-Idel J, Stellmacher F, Jann F, Kalms N, König IR, Ohlrich M, Royl G, Klotz S, Kurz T, Kemmling A, and Roessler FC
- Abstract
Background: Thrombus histology has become a potential diagnostic tool for the etiology assessment of patients with ischemic stroke caused by embolic proximal vessel occlusion. We validated a classification rule that differentiates between cardiac and arteriosclerotic emboli in individual stroke patients. We aim to describe in detail the development of this classification rule and disclose its reliability., Methods: The classification rule is based on the hypothesis that cardiac emboli arise out of separation thrombi and arteriosclerotic emboli result from agglutinative thrombi. 125 emboli recovered by thrombectomy from stroke patients and 11 thrombi serving as references for cardiac (n = 5) and arteriosclerotic emboli (n = 6) were Hematoxylin and eosin, Elastica-van Gieson and CD61 stained and rated independently by two histopathologists blinded to the presumed etiology by several pre-defined criteria. Intra- and interobserver reliabilities of all criteria were determined. Out of the different criteria, three criteria with the most satisfactory reliability values were selected to compose the classification rule that was finally adjusted to the reference thrombi. Reliabilities of the classification rule were calculated by using the emboli of stroke patients., Results: The classification rule reached intraobserver reliabilities for the two raters of 92.9% and 68.2%, respectively. Interobserver reliability was 69.9%., Conclusions: A new classification rule for emboli obtained from thrombectomy was established. Within the limitations of histological investigations, it is reliable and able to distinguish between cardioembolic and arteriosclerotic emboli., (© 2021. The Author(s).)
- Published
- 2021
- Full Text
- View/download PDF
5. First approach to distinguish between cardiac and arteriosclerotic emboli of individual stroke patients applying the histological THROMBEX-classification rule.
- Author
-
Roessler FC, Kalms N, Jann F, Kemmling A, Ribbat-Idel J, Stellmacher F, König IR, Ohlrich M, and Royl G
- Subjects
- Cohort Studies, Diagnosis, Differential, Embolism classification, Embolism diagnosis, Embolism etiology, Histological Techniques methods, Humans, Arteriosclerosis diagnosis, Arteriosclerosis pathology, Embolic Stroke diagnosis, Embolic Stroke pathology, Stroke classification, Stroke diagnosis, Stroke etiology, Thrombosis pathology
- Abstract
Endovascular treatment of strokes caused by large vessel occlusion enables the histopathological investigation of the retrieved embolus, possibly providing a novel opportunity to contribute to the diagnostic workup of etiology and to define secondary prevention measures in strokes with uncertain genesis. We aimed to develop a classification rule based on pathophysiological considerations and adjustment to reference thrombi for distinction between cardiac and arteriosclerotic emboli and to validate this classification rule on a patient cohort. From 125 patients with stroke due to large vessel occlusion and thrombectomy, 82 patients with known etiology (55 cardioembolic and 27 arterioembolic strokes) were included. The corresponding emboli were histologically evaluated by two raters blinded to the etiology of stroke by means of a novel classification rule. Presumed etiology and classification results were compared. Agreement concerning cardiac emboli was 72.2% (95% CI: 58.4-83.5) for rater I and 78.2% (95% CI: 65.0-88.2) for rater II. Agreement concerning arteriosclerotic emboli was 70.4% (95% CI: 49.8-86.3) for rater I and 74.1% (95% CI: 53.7-88.9) for rater II. Overall agreement reached 71.6% (95% CI: 60.5-81.1) for rater I and 76.8% (95% CI: 66.2-85.4) for rater II. Within the limits of generally restricted accuracy of histological evaluations, the classification rule differentiates between cardiac and arteriosclerotic emboli of acute ischemic stroke patients. Further improvement is needed to provide valuable complementary data for stroke etiology workup.
- Published
- 2021
- Full Text
- View/download PDF
6. In vitro examination of the thrombolytic efficacy of tenecteplase and therapeutic ultrasound compared to rt-PA.
- Author
-
Frühwald T, Gärtner U, Stöckmann N, Marxsen JH, Gramsch C, and Roessler FC
- Subjects
- Drug Evaluation, Preclinical, Humans, Stroke drug therapy, Tissue Plasminogen Activator therapeutic use, Fibrinolytic Agents therapeutic use, Tenecteplase therapeutic use, Thrombolytic Therapy methods, Thrombosis drug therapy, Ultrasonic Therapy
- Abstract
Background: Optimizing thrombolytic therapy is vital for improving stroke outcomes. We aimed to develop standardized thrombolysis conditions to evaluate the efficacy of tenecteplase (TNK) compared to the current gold standard rt-PA (alteplase), with and without additional ultrasound treatment. We also wanted to introduce a new analytical approach to quantify fibrin fiber density in transmission electron microscopy (TEM)., Methods: In vitro clots that are similar to ex vivo clots concerning their histological condition and their durability were generated from whole blood. For five treatment groups we compared relative clot weight loss (each n = 60) and fibrin fiber density in TEM (each n = 5). The control group (A) was treated only with plasma. Two groups were designated for each rt-PA (B + C) and TNK (D + E). Groups C and E were additionally treated with ultrasound. Dosages were 50 μg/ml for rt-PA and 30 μg/ml for TNK. Results were evaluated by using analyses of variance (ANOVA) and post-hoc t-tests., Results: Weight loss was increased significantly for all groups compared to the control group. Both TNK groups showed significantly increased weight loss compared to their counterpart rt-PA group (p ≤ 0.001). For TEM only group D showed significantly decreased fibrin fiber density (p < 0.05) compared to both rt-PA groups. Ultrasound did not significantly increase dissolution of clots with either method (best p = 0.16)., Conclusions: Tenecteplase dissolved clots more effectively than rt-PA with and without ultrasound. A higher sample size could provide more convincing results for TEM.
- Published
- 2019
- Full Text
- View/download PDF
7. Speckle Tracking in Transcranial Ultrasound Allows Noninvasive Analysis of Pulsation Patterns of the Third Ventricle.
- Author
-
Würzer B, Laza C, Pons-Kühnemann J, Kaps M, Junge B, and Roessler FC
- Subjects
- Adult, Blood Flow Velocity, Electrocardiography, Female, Humans, Male, Third Ventricle diagnostic imaging, Third Ventricle physiology, Young Adult, Hydrocephalus physiopathology, Image Processing, Computer-Assisted methods, Third Ventricle physiopathology, Ultrasonography, Doppler, Transcranial methods
- Abstract
Cerebrospinal fluid (CSF) flow is sensitive to many cerebral disorders. We aimed to develop a noninvasive bedside method to detect physiological and pathological CSF phenomena by measuring pulsation patterns of the third ventricle. By transcranial B-mode ultrasound, electrocardiography (ECG)-gated video loops of the third ventricle were acquired. "Speckle tracking" software was used to quantify the relative change of its width. We conducted measurements of nine cardiac cycles in 11 healthy subjects in sitting and in supine position during Valsalva maneuver to investigate the influence of an increased intracranial pressure on the relative deformation of the third ventricle. In one patient with occlusive hydrocephalus, 19 cardiac cycles were measured in sitting position before and after removal of a tumorous obstruction of the aqueduct of Sylvius. Healthy subjects expressed a pulse-related increased width of the third ventricle ([Formula: see text]: +5.69, 95% confidence interval [CI] = [4.38, 7.00]). No significant difference was found between the sitting and the supine position in healthy adults. In the preoperative state of occlusive hydrocephalus, we found a negative, pulse-related deformation ([Formula: see text]: -1.86, 95% CI = [-2.15, -1.58]) with delayed onset. After surgery, the deformation pattern resembled that of our healthy controls. The difference between pre- and postoperative condition was significant (p < 0.001). Transcranial B-mode sonography can be used to record small movements of the sidewalls of the third ventricle. This noninvasive bedside method is suitable to assess CSF pulsatility within the third ventricle and might be able to distinguish between physiological and pathological flows.
- Published
- 2018
- Full Text
- View/download PDF
8. Rapid healing of a patient with dramatic subacute combined degeneration of spinal cord: a case report.
- Author
-
Roessler FC and Wolff S
- Subjects
- Antibodies chemistry, Gastrins chemistry, Gastroscopy, Homocysteine blood, Humans, Inflammation, Male, Methylmalonic Acid blood, Middle Aged, Parietal Cells, Gastric cytology, Transcobalamins chemistry, Vitamin B 12 Deficiency complications, Spinal Cord pathology, Subacute Combined Degeneration therapy
- Abstract
Background: Prevalence of cobalamin deficiency is high especially in older patients and an immediate therapy start is necessary to prevent irreversible neurological damages. Unfortunately, the diagnosis of cobalamin deficiency is difficult and at present, there is no consensus for diagnosis of this deficiency. Therefore, we aim to elucidate a meaningful diagnostic pathway by a case report with an initially misleading medical history., Case Presentation: A 57 year-old Caucasian man suffering from dramatic myelosis of the cervical posterior columns. Apart from associated neurological symptoms (tactile hypaesthesia, reduced vibration sensation, loss of stereognosis and of two-point-discrimination) there were no further complaints; especially no gastrointestinal, haematological or psychiatric disorders were provable. Cobalamin (vitamin B12) serum level was normal. The diagnosis of subacute combined degeneration of spinal cord was confirmed by an elevated methylmalonic acid, and hyperhomocysteinemia. Cobalamin deficiency was caused by asymptomatic chronic atrophic inflammation of the stomach with a lack of intrinsic factor producing gland cells. This was revealed by increased gastrin and parietal cell antibodies and finally confirmed by gastroscopy. Parenteral substitution of cobalamin rapidly initiated regeneration., Conclusions: This case demonstrates that normal cobalamin serum levels do not rule out a cobalamin deficiency. In contrast, path-breaking results can be achieved by determining homocysteine, holotranscobalamin, and methylmalonic acid.
- Published
- 2017
- Full Text
- View/download PDF
9. Clot Formation in the Presence of Acetylsalicylic Acid Leads to Increased Lysis Rates Regardless of the Chosen Thrombolysis Strategy.
- Author
-
Roessler FC, Schumacher S, Sprenger A, Gärtner U, Al-Khaled M, and Eggers J
- Subjects
- Fibrin ultrastructure, Humans, Kinetics, Aspirin pharmacology, Fibrin metabolism, Fibrinolysis drug effects, Fibrinolytic Agents pharmacology, Plasminogen Activators pharmacology, Thrombolytic Therapy methods, Ultrasonic Therapy
- Abstract
Background: Patients with acute ischemic strokes frequently take an acetylsalicylic acid (ASA) premedication. We determined the impact of ASA on different thrombolysis strategies in vitro., Methods: For two clot types made from platelet-rich plasma (one with and one without ASA) lysis rates were measured by weight loss after 1 h for five different groups: in control group A clots were solely placed in plasma; in groups B and C clots were treated with rt-PA (60 kU/ml), and in groups D and E clots were treated with desmoteplase (DSPA; 2 µg/ml). Ultrasound (2 MHz, 0.179 W/cm2) was included in groups C and E. The fibrin mesh structures of the clots were investigated by electron microscopy., Results: For both clot types lysis rates increased significantly for all treatment strategies compared to their control group (each p < 0.001). The addition of ASA significantly increased the lysis rate in all 5 groups (each p < 0.001) and led to a ceiling effect concerning the treatment. A semiquantitative analysis of transmission electron micrographs revealed a decreased fibrin density for clots with ASA. For both clot types DSPA and ultrasound led to a significant dissolution of the fibrin mesh (both p = 0.029)., Conclusions: In vitro ASA pretreatment leads to significantly increased lysis rates due to a weaker fibrin mesh in platelet-rich plasma clots., (© 2016 S. Karger AG, Basel.)
- Published
- 2016
- Full Text
- View/download PDF
10. In Vitro Examination of the Thrombolytic Efficacy of Desmoteplase and Therapeutic Ultrasound Compared with rt-PA.
- Author
-
Roessler FC, Wang Z, Schumacher S, Ohlrich M, Kaps M, Menciassi A, and Eggers J
- Subjects
- Analysis of Variance, Combined Modality Therapy, Humans, In Vitro Techniques, Reproducibility of Results, Fibrinolytic Agents pharmacology, Plasminogen Activators pharmacology, Thrombolytic Therapy methods, Thrombosis therapy, Tissue Plasminogen Activator pharmacology, Ultrasonic Therapy methods
- Abstract
The aim of the study described here was to evaluate the thrombolytic efficacy of combined treatment with the fibrin-selective plasminogen activator desmoteplase (DSPA) and therapeutic ultrasound (sonothrombolysis [STL]) compared with conventional rt-PA (recombinant tissue plasminogen activator) treatment in vitro. Lysis rates were determined by the weight loss of platelet-rich plasma (PRP) clots treated with rt-PA (60 kU/mL) or DSPA (2 μg/mL) combined with pulsed wave ultrasound (2 MHz, 0.179 W/cm(2)). To reveal the individual effects of medication and ultrasound, lysis rates were also determined for DSPA monotherapy and for combined treatment with rt-PA and ultrasound. Clots solely placed in plasma served as the control group. Lysis increased significantly with rt-PA (26.5 ± 7.8%) and DSPA (30.5 ± 6%) compared with the control group (18.2 ± 5.9%) (each p < 0.001). DSPA lysis was more effective than rt-PA lysis (without STL: p = 0.015, with STL: p = 0.01). Combined treatment with DSPA and 2-MHz STL significantly exceeded rt-PA lysis (32.8% vs. 26.5%, p < 0.001)., (Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.)
- Published
- 2015
- Full Text
- View/download PDF
11. Development of a new clot formation protocol for standardized in vitro investigations of sonothrombolysis.
- Author
-
Roessler FC, Teichert A, Ohlrich M, Marxsen JH, Stellmacher F, Tanislav C, and Seidel G
- Subjects
- Blood Cell Count, Fibrin Clot Lysis Time, Fibrinolytic Agents pharmacology, Humans, In Vitro Techniques, Models, Statistical, Tissue Plasminogen Activator pharmacology, Blood Coagulation drug effects, Research Design standards, Sound Spectrography methods, Sound Spectrography standards, Thrombosis therapy
- Abstract
Background: Agreement about the most suitable clot formation protocol for sonothrombolysis investigations is lacking. Lysis rates vary strongly owing to different test conditions and, thus, cannot be compared. We aim to establish a simple but physiologically grounded protocol for in vitro coagulation to enable standardized sonothrombolysis investigations., Method: Clots were generated from platelet-rich plasma (PRP) obtained by centrifugation (10 min, 180 × g) of human venous blood (VB). PRP was mixed with the boundary layer formed between the supernatant and the erythrocyte layer. To achieve clots with different platelet counts, PRP was gradually substituted with platelet-free plasma (PFP), harvested from the supernatant of VB after centrifugation (10 min, 2570 × g). Clot types were examined for histological appearance, hydrodynamic resistance under physiological flows, and lysis rate measured by weight loss after a 2-h treatment with recombinant tissue plasminogen activator (rt-PA) (60 kU/ml). Lysis rates of the most suitable clot were measured after a 1-h treatment with rt-PA (60 kU/ml), and combined treatment with rt-PA and 2-MHz transcranial color-coded sonography (TCCS) (0.179 W/cm(2)) or 2-MHz transcranial Doppler (TCD) (0.457 W/cm(2))., Results: With increased platelet count, the hydrodynamic resistance of the artificial clots increased, their histological appearance became more physiological, and lysis rates decreased. The most suitable clots consisted of 1.5-ml PRP, 2.0-ml PFP, and 0.5-ml boundary layer. Their lysis rates were 36.7 ± 7.8% (rt-PA), 40.8 ± 8.6% (rt-PA+TCCS), and 40.4 ± 8.3% (rt-PA+TCD)., Comparison With Existing Methods: These systemic investigations were conducted for the first time., Conclusion: This protocol should be used for standardized sonothrombolysis investigations., (Copyright © 2014 Elsevier B.V. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
12. The platelet-rich plasma clot: a standardized in-vitro clot formation protocol for investigations of sonothrombolysis under physiological flows.
- Author
-
Roessler FC, Ohlrich M, Marxsen JH, Stellmacher F, Sprenger A, Dempfle CE, and Seidel G
- Subjects
- Humans, Kinetics, Models, Biological, Perfusion methods, Reference Standards, Thrombolytic Therapy standards, Blood Coagulation, Platelet-Rich Plasma physiology, Research Design standards, Thrombolytic Therapy methods
- Abstract
No agreement exists about which protocol for in-vitro clot formation is suitable for sonothrombolysis investigations. Lysis rates vary considerably because of different clotting processes and cannot be compared. We aim to establish a new protocol for in-vitro coagulation to permit standardized sonothrombolysis investigations. The proposed procedure is based upon clots prepared from platelet-rich plasma (PRP). This clot material (group A) was compared with the two most commonly used procedures, namely, recalcification of citrate-anticoagulated whole venous blood (group B) and spontaneous clotting of nonanticoagulated venous blood (group C). Histological examinations were performed and clot stability was tested under physiological flow conditions in vitro for all groups (each n = 10). Lysis rates measured by mass loss were compared using buffered plasma and recombinant tissue plasminogen activator (60 kU/ml), or buffered plasma alone. PRP clots displayed a high degree of similarity to emboli specimens in histological examinations and remained stable under pulsatile flow conditions. B and C clots were mechanically unstable and did not resist physiological flow and pressure. Measuring the lysis rate by weighing seems to be inaccurate, with lowest variability in PRP clots. PRP clots appeared more resistant to lysis. PRP clots should be used for standardized sonothrombolysis investigations.
- Published
- 2011
- Full Text
- View/download PDF
13. Introduction of a new model for time-continuous and non-contact investigations of in-vitro thrombolysis under physiological flow conditions.
- Author
-
Roessler FC, Ohlrich M, Marxsen JH, Schmieger M, Weber PK, Stellmacher F, Trillenberg P, Eggers J, and Seidel G
- Subjects
- Blood Flow Velocity, Humans, Hydrodynamics, In Vitro Techniques, Reproducibility of Results, Time Factors, Computer Simulation, Models, Biological, Thrombosis pathology, Thrombosis physiopathology
- Abstract
Background: Thrombolysis is a dynamic and time-dependent process influenced by the haemodynamic conditions. Currently there is no model that allows for time-continuous, non-contact measurements under physiological flow conditions. The aim of this work was to introduce such a model., Methods: The model is based on a computer-controlled pump providing variable constant or pulsatile flows in a tube system filled with blood substitute. Clots can be fixed in a custom-built clot carrier within the tube system. The pressure decline at the clot carrier is measured as a novel way to measure lysis of the clot. With different experiments the hydrodynamic properties and reliability of the model were analyzed. Finally, the lysis rate of clots generated from human platelet rich plasma (PRP) was measured during a one hour combined application of diagnostic ultrasound (2 MHz, 0.179 W/cm2) and a thrombolytic agent (rt-PA) as it is commonly used for clinical sonothrombolysis treatments., Results: All hydrodynamic parameters can be adjusted and measured with high accuracy. First experiments with sonothrombolysis demonstrated the feasibility of the model despite low lysis rates., Conclusions: The model allows to adjust accurately all hydrodynamic parameters affecting thrombolysis under physiological flow conditions and for non-contact, time-continuous measurements. Low lysis rates of first sonothrombolysis experiments are primarily attributable to the high stability of the used PRP-clots.
- Published
- 2011
- Full Text
- View/download PDF
14. Simulation of cerebral hemodynamics for preoperative risk assessment.
- Author
-
Roessler FC, Reith W, and Siegel G
- Subjects
- Brain blood supply, Brain physiology, Carotid Arteries anatomy & histology, Carotid Arteries diagnostic imaging, Carotid Arteries physiology, Cerebral Arteries physiology, Cerebral Arteries surgery, Cerebrovascular Disorders physiopathology, Cerebrovascular Disorders surgery, Circle of Willis anatomy & histology, Circle of Willis diagnostic imaging, Humans, Intraoperative Complications etiology, Intraoperative Complications physiopathology, Magnetic Resonance Angiography, Models, Biological, Nonlinear Dynamics, Risk Assessment methods, Ultrasonography, Doppler, Duplex, Vertebral Artery anatomy & histology, Vertebral Artery physiology, Vertebral Artery surgery, Cerebrovascular Circulation physiology, Circle of Willis physiology, Embolization, Therapeutic adverse effects, Embolization, Therapeutic methods, Intraoperative Complications prevention & control, Preoperative Care methods
- Abstract
Background: An important part of the medical treatment of many cerebrovascular diseases is the occlusion of brain supplying arteries. Until now, the risk of this intervention can only be estimated by invasive diagnostics including the risk of cerebrovascular accidents., Methods and Results: As a supporting tool, a computer model of the circle of Willis was designed. The model is based upon linear differential equations describing electrotechnical circuits extended non-linearly. By these means, time continuous simulations of different states and the online observation of all calculated state variables such as blood pressure and blood flow in every modeled vessel became feasible. For individual simulations, model parameters were determined by MR-angiography and boundary values by simultaneous Duplex-measurements in both carotid and vertebral arteries. State variables generated by the model behaved physiologically and the reaction of individual cerebrovascular systems in critical situations could be investigated by special scenarios. Inaccuracies concerning the determination of model parameters and boundary values of the used differential equations are likely to be resolved in the near future through a more careful and technically improved determination of these values., Conclusions: Computer models of subjects were created taking in account the individual anatomical and non-linear physical properties of real vascular systems supplying the brain. Thereby information could be obtained concerning the hemodynamic effects of an iatrogenic vascular occlusion.
- Published
- 2006
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.