36 results on '"Rietbergen, DDD"'
Search Results
2. Freehand SPECT Combined with 3-Dimensional Light Detection and Ranging as Alternative Means of Specimen Scanning During Prostate Cancer Surgery.
- Author
-
Pisano G, van Oosterom MN, Berrens AC, Slof LJ, Rietbergen DDD, van der Poel HG, van Leeuwen PJ, and van Leeuwen FWB
- Published
- 2024
- Full Text
- View/download PDF
3. The Rise of Molecular Image-Guided Robotic Surgery.
- Author
-
van Leeuwen FWB, Buckle T, van Oosterom MN, and Rietbergen DDD
- Subjects
- Humans, Robotic Surgical Procedures methods, Molecular Imaging methods, Surgery, Computer-Assisted methods
- Abstract
Following early acceptance by urologists, the use of surgical robotic platforms is rapidly spreading to other surgical fields. This empowerment of surgical perception via robotic advances occurs in parallel to developments in intraoperative molecular imaging. Convergence of these efforts creates a logical incentive to advance the decades-old image-guided robotics paradigm. This yields new radioguided surgery strategies set to optimally exploit the symbiosis between the growing clinical translation of robotics and molecular imaging. These strategies intend to advance surgical precision by increasing dexterity and optimizing surgical decision-making. In this state-of-the-art review, topic-related developments in chemistry (tracer development) and engineering (medical device development) are discussed, and future scientific robotic growth markets for molecular imaging are presented., (© 2024 by the Society of Nuclear Medicine and Molecular Imaging.)
- Published
- 2024
- Full Text
- View/download PDF
4. Setting-up a training programme for intraoperative molecular imaging and sentinel node mapping: how to teach? How to learn?
- Author
-
Valdés Olmos RA, Collarino A, Rietbergen DDD, Pereira Arias-Bouda L, Giammarile F, and Vidal-Sicart S
- Subjects
- Humans, Sentinel Lymph Node diagnostic imaging, Sentinel Lymph Node surgery, Intraoperative Period, Surgery, Computer-Assisted methods, Surgery, Computer-Assisted education, Molecular Imaging methods, Sentinel Lymph Node Biopsy methods
- Abstract
Background: The current expansion of image-guided surgery is closely related to the role played by radio-guided surgery in supporting the sentinel node (SN) procedure during more than three decades. The so-called triple approach (lymphoscintigraphy, gamma probe detection and blue dye) was not only essential in the seminal validation of the SN procedure but also a first collective learning effort based on skill transfer and outcome-related evaluation which laid the fundaments to delineate the field of intraoperative molecular imaging (IMI) based on a similar multimodality approach and multidisciplinary practice., Methods: These elements are also becoming valid in the current incorporation of SPECT/CT and PET/CT to existing and new protocols of IMI procedures and SN mapping concerning other clinical applications. On the other hand, there is a growing tendency to combine novel modern technologies in an allied role with gamma guidance in the operating room following the development of hybrid tracers and multimodal detection approaches. Against this background, learning initiatives are required for professionals working in this area., Results: This objective has led to a group of European practitioners with large experience in SN mapping and IMI applications to give shape to a programme made up out of specific learning modules aimed to be used as a conductive thread in peripherical or centralised training instances concerning the topic., Conclusion: The presented work, written as a tutorial review, is placed in an available prior-art context and is primarily aimed at medical and paramedical practitioners as well as at hardware and software developers., (© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
- Published
- 2024
- Full Text
- View/download PDF
5. h HEPATO-Cy5, a Bimodal Tracer for Image-Guided Hepatobiliary Surgery.
- Author
-
Rietbergen DDD, Buckle T, Slof LJ, van Meerbeek MP, de Korne CM, Welling MM, van Oosterom MN, Bauwens K, Roestenberg M, Kloetzl J, and van Leeuwen FWB
- Subjects
- Animals, Mice, Liver diagnostic imaging, Liver metabolism, Liver surgery, Tissue Distribution, Humans, Radioactive Tracers, Single Photon Emission Computed Tomography Computed Tomography, Swine, Hepatocytes metabolism, Carbocyanines chemistry, Surgery, Computer-Assisted
- Abstract
Liver cancer is a leading cause of cancer deaths worldwide. Surgical resection of superficial hepatic lesions is increasingly guided by the disrupted bile excretion of the fluorescent dye indocyanine green (ICG). To extend this approach to deeper lesions, a dedicated bimodal tracer that facilitates both fluorescence guidance and radioguidance was developed. Methods: A tracer comprising a methylated cyanine-5 (Cy5) fluorescent dye and a mercaptoacetyltriserine chelate ( h HEPATO-Cy5) was synthesized and characterized. Cellular uptake and excretion were evaluated in hepatocyte cultures (2-dimensional culture and in vitro lesion model), using a fluorescent bile salt, MitoTracker dye, and methylated Cy5 as a control. After radiolabeling, the pharmacokinetics of
99m Tc- h HEPATO-Cy5 were assessed in mice over 24 h (percentage injected dose and percentage injected dose per gram of tissue, SPECT/CT imaging and fluorescence imaging). The ability to provide real-time fluorescence guidance during robot-assisted hepatobiliary surgery was evaluated in a porcine model using ICG as a reference. Results: The unique molecular signature of h HEPATO-Cy5 promotes hepatobiliary excretion. In vitro studies on hepatocytes showed that where methylated Cy5 remained internalized, h HEPATO-Cy5 showed fast clearance (10 min) similar to that of fluorescent bile salt. In vivo use of99m Tc- h HEPATO-Cy5 in mice revealed liver accumulation and rapid biliary clearance. The effectiveness of bile clearance was best exemplified by the 2-orders-of-magnitude reduction in count rate for the gallbladder ( P = 0.008) over time. During hepatobiliary surgery in a porcine model, h HEPATO-Cy5 enabled fluorescence-based lesion identification comparable to that of ICG. Conclusion: The bimodal99m Tc- h HEPATO-Cy5 provides an effective means to identify liver lesions. Uniquely, it helps overcome the shortcomings of fluorescence-only approaches by allowing for an extension to in-depth radioguidance., (© 2024 by the Society of Nuclear Medicine and Molecular Imaging.)- Published
- 2024
- Full Text
- View/download PDF
6. Molecular image-guided surgery in gynaecological cancer: where do we stand?
- Author
-
Pisano G, Wendler T, Valdés Olmos RA, Garganese G, Rietbergen DDD, Giammarile F, Vidal-Sicart S, Oonk MHM, Frumovitz M, Abu-Rustum NR, Scambia G, Rufini V, and Collarino A
- Subjects
- Humans, Female, Genital Neoplasms, Female diagnostic imaging, Genital Neoplasms, Female surgery, Surgery, Computer-Assisted methods, Molecular Imaging methods
- Abstract
Purpose: The aim of this review is to give an overview of the current status of molecular image-guided surgery in gynaecological malignancies, from both clinical and technological points of view., Methods: A narrative approach was taken to describe the relevant literature, focusing on clinical applications of molecular image-guided surgery in gynaecology, preoperative imaging as surgical roadmap, and intraoperative devices., Results: The most common clinical application in gynaecology is sentinel node biopsy (SNB). Other promising approaches are receptor-target modalities and occult lesion localisation. Preoperative SPECT/CT and PET/CT permit a roadmap for adequate surgical planning. Intraoperative detection modalities span from 1D probes to 2D portable cameras and 3D freehand imaging., Conclusion: After successful application of radio-guided SNB and SPECT, innovation is leaning towards hybrid modalities, such as hybrid tracer and fusion of imaging approaches including SPECT/CT and PET/CT. Robotic surgery, as well as augmented reality and virtual reality techniques, is leading to application of these innovative technologies to the clinical setting, guiding surgeons towards a precise, personalised, and minimally invasive approach., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
7. Lessons learned in application driven imaging agent design for image-guided surgery.
- Author
-
Buckle T, Rietbergen DDD, de Wit-van der Veen L, and Schottelius M
- Subjects
- Humans, Molecular Imaging methods, Animals, Drug Design, Surgery, Computer-Assisted methods
- Abstract
To meet the growing demand for intraoperative molecular imaging, the development of compatible imaging agents plays a crucial role. Given the unique requirements of surgical applications compared to diagnostics and therapy, maximizing translational potential necessitates distinctive imaging agent designs. For effective surgical guidance, exogenous signatures are essential and are achievable through a diverse range of imaging labels such as (radio)isotopes, fluorescent dyes, or combinations thereof. To achieve optimal in vivo utility a balanced molecular design of the tracer as a whole is required, which ensures a harmonious effect of the imaging label with the affinity and specificity (e.g., pharmacokinetics) of a pharmacophore/targeting moiety. This review outlines common design strategies and the effects of refinements in the molecular imaging agent design on the agent's pharmacological profile. This includes the optimization of affinity, pharmacokinetics (including serum binding and target mediated background), biological clearance route, the achievable signal intensity, and the effect of dosing hereon., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
8. Delphi consensus project on prostate-specific membrane antigen (PSMA)-targeted surgery-outcomes from an international multidisciplinary panel.
- Author
-
Berrens AC, Scheltema M, Maurer T, Hermann K, Hamdy FC, Knipper S, Dell'Oglio P, Mazzone E, de Barros HA, Sorger JM, van Oosterom MN, Stricker PD, van Leeuwen PJ, Rietbergen DDD, Valdes Olmos RA, Vidal-Sicart S, Carroll PR, Buckle T, van der Poel HG, and van Leeuwen FWB
- Subjects
- Humans, Male, Positron Emission Tomography Computed Tomography, Molecular Targeted Therapy, Antigens, Surface metabolism, Glutamate Carboxypeptidase II metabolism, Delphi Technique, Prostatic Neoplasms surgery, Prostatic Neoplasms diagnostic imaging, Consensus
- Abstract
Purpose: Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore expert views in this emerging field and to identify knowledge and evidence gaps as well as unmet research needs that may help change practice and improve oncological outcomes for patients., Methods: One hundred and five statements (scored by a 9-point Likert scale) were distributed through SurveyMonkey®. Following evaluation, a consecutive second round was performed to evaluate consensus (16 statements; 89% response rate). Consensus was defined using the disagreement index, assessed by the research and development project/University of California, Los Angeles appropriateness method., Results: Eighty-six panel participants (72.1% clinician, 8.1% industry, 15.1% scientists, and 4.7% other) participated, most with a urological background (57.0%), followed by nuclear medicine (22.1%). Consensus was obtained on the following: (1) The diagnostic PSMA-ligand PET/CT should ideally be taken < 1 month before surgery, 1-3 months is acceptable; (2) a 16-20-h interval between injection of the tracer and surgery seems to be preferred; (3) PSMA targeting is most valuable for identification of nodal metastases; (4) gamma, fluorescence, and hybrid imaging are the preferred guidance technologies; and (5) randomized controlled clinical trials are required to define oncological value. Regarding surgical margin assessment, the view on the value of PSMA-targeted surgery was neutral or inconclusive. A high rate of "cannot answer" responses indicates further study is necessary to address knowledge gaps (e.g., Cerenkov or beta-emissions)., Conclusions: This Delphi consensus provides guidance for clinicians and researchers that implement or develop PSMA-targeted surgery technologies. Ultimately, however, the consensus should be backed by randomized clinical trial data before it may be implemented within the guidelines., (© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
- Published
- 2024
- Full Text
- View/download PDF
9. Augmenting CT-Guided Bone Biopsies Using 18 F-FDG PET/CT Guidance.
- Author
-
Droste MF, van Velden FHP, van Oosterom MN, Luijk VJ, Burgmans MC, Buckle T, van Leeuwen FWB, and Rietbergen DDD
- Abstract
Computer tomography (CT)-guided percutaneous core biopsies are currently the gold standard in diagnostic procedures for patients with bone lesions of unknown kind. CT-guided biopsies can lead to misdiagnosis or repetition of biopsies in case of small or heterogeneous lesions. We hypothesize that molecular image guidance could be used to optimize the biopsy strategy, by supporting the detection of heterogeneous lesions or lesions without radiographic substrate. To evaluate this hypothesis, we investigated if and how the addition of 2-deoxy-2-
18 F-fluoro-D-glucose-positron emission tomography (18 F-FDG-PET)/CT could augment routine CT-guided bone biopsies. To this end, 106 patients who underwent a CT-guided bone biopsy between April 2019 and April 2020, obtained from either a vertebral or peripheral bone, were included. Patients were divided into 2 groups: 36 patients received an18 F-FDG-PET/CT scan prior to their CT-guided bone biopsy (PET group), while 70 patients only had a morphological CT scan (CT group). Histopathology was used to categorize biopsies into five subgroups (inconclusive, benign, malignant or infectious disease, or normal tissue). In the PET group, the number of conclusive biopsies was significantly higher compared to the CT group (N = 33/36 (92%) versus N = 53/70 (76%); p < 0.05). Furthermore, the number of first-try biopsies was lower in the PET group compared to the CT group (1.9 vs. 2.54, p = 0.051). In conclusion,18 F-FDG-PET/CT imaging significantly increased the success rate of first-try CT-guided bone biopsies by showing less inconclusive biopsies and misdiagnosis.- Published
- 2024
- Full Text
- View/download PDF
10. Extrahepatic perfusion and incomplete hepatic perfusion after hepatic arterial infusion pump implantation: incidence and clinical implications.
- Author
-
Filipe WF, Buisman FE, Franssen S, Krul MF, Grünhagen DJ, Bennink RJ, Bolhuis K, Bruijnen RCG, Buffart TE, Burgmans MC, van Delden OM, Doornebosch PG, Gobardhan PD, Graven L, de Groot JWB, Grootscholten C, Hagendoorn J, Harmsen P, Homs MYV, Klompenhouwer EG, Kok NFM, Lam MGEH, Loosveld OJL, Meier MAJ, Mieog JSD, Oostdijk AHJ, Outmani L, Patijn GA, Pool S, Rietbergen DDD, Roodhart JML, Speetjens FM, Swijnenburg RJ, Versleijen MWJ, Verhoef C, Kuhlmann KFD, Moelker A, and Groot Koerkamp B
- Subjects
- Aged, Female, Humans, Male, Middle Aged, Antineoplastic Agents administration & dosage, Incidence, Infusion Pumps, Implantable, Liver Circulation, Liver Neoplasms surgery, Methylene Blue administration & dosage, Netherlands epidemiology, Retrospective Studies, Single Photon Emission Computed Tomography Computed Tomography, Technetium Tc 99m Aggregated Albumin administration & dosage, Hepatic Artery diagnostic imaging, Infusions, Intra-Arterial
- Abstract
Introduction: This study investigates the incidence of extrahepatic perfusion and incomplete hepatic perfusion at intraoperative methylene blue testing and on postoperative nuclear imaging in patients undergoing hepatic arterial infusion pump (HAIP) chemotherapy., Methods: The first 150 consecutive patients who underwent pump implantation in the Netherlands were included. All patients underwent surgical pump implantation with the catheter in the gastroduodenal artery. All patients underwent intraoperative methylene blue testing and postoperative nuclear imaging (
99m Tc-Macroaggregated albumin SPECT/CT) to determine perfusion via the pump., Results: Patients were included between January-2018 and December-2021 across eight centers. During methylene blue testing, 29.3% had extrahepatic perfusion, all successfully managed intraoperatively. On nuclear imaging, no clinically relevant extrahepatic perfusion was detected (0%, 95%CI: 0.0-2.5%). During methylene blue testing, 2.0% had unresolved incomplete hepatic perfusion. On postoperative nuclear imaging, 8.1% had incomplete hepatic perfusion, leading to embolization in only 1.3%., Conclusion: Methylene blue testing during pump placement for intra-arterial chemotherapy identified extrahepatic perfusion in 29.3% of patients, but could be resolved intraoperatively in all patients. Postoperative nuclear imaging found no clinically relevant extrahepatic perfusion and led to embolization in only 1.3% of patients. The role of routine nuclear imaging after HAIP implantation should be studied in a larger cohort., (Copyright © 2024 The Authors. Published by Elsevier Ltd.. All rights reserved.)- Published
- 2024
- Full Text
- View/download PDF
11. Adjuvant holmium-166 radioembolization after radiofrequency ablation in early-stage hepatocellular carcinoma patients: a dose-finding study (HORA EST HCC trial).
- Author
-
Hendriks P, Rietbergen DDD, van Erkel AR, Coenraad MJ, Arntz MJ, Bennink RJ, Braat AE, Crobach S, van Delden OM, Dibbets-Schneider P, van der Hulle T, Klümpen HJ, van der Meer RW, Nijsen JFW, van Rijswijk CSP, Roosen J, Ruijter BN, Smit F, Stam MK, Takkenberg RB, Tushuizen ME, van Velden FHP, de Geus-Oei LF, and Burgmans MC
- Subjects
- Humans, Male, Female, Aged, Middle Aged, Radiofrequency Ablation methods, Radiotherapy Dosage, Neoplasm Staging, Tissue Distribution, Carcinoma, Hepatocellular radiotherapy, Carcinoma, Hepatocellular therapy, Carcinoma, Hepatocellular diagnostic imaging, Liver Neoplasms radiotherapy, Liver Neoplasms therapy, Holmium therapeutic use, Embolization, Therapeutic methods, Radioisotopes therapeutic use, Radioisotopes administration & dosage
- Abstract
Purpose: The aim of this study was to investigate the biodistribution of (super-)selective trans-arterial radioembolization (TARE) with holmium-166 microspheres (
166 Ho-MS), when administered as adjuvant therapy after RFA of HCC 2-5 cm. The objective was to establish a treatment volume absorbed dose that results in an absorbed dose of ≥ 120 Gy on the hyperemic zone around the ablation necrosis (i.e., target volume)., Methods: In this multicenter, prospective dose-escalation study in BCLC early stage HCC patients with lesions 2-5 cm, RFA was followed by (super-)selective infusion of166 Ho-MS on day 5-10 after RFA. Dose distribution within the treatment volume was based on SPECT-CT. Cohorts of up to 10 patients were treated with an incremental dose (60 Gy, 90 Gy, 120 Gy) of166 Ho-MS to the treatment volume. The primary endpoint was to obtain a target volume dose of ≥ 120 Gy in 9/10 patients within a cohort., Results: Twelve patients were treated (male 10; median age, 66.5 years (IQR, [64.3-71.7])) with a median tumor diameter of 2.7 cm (IQR, [2.1-4.0]). At a treatment volume absorbed dose of 90 Gy, the primary endpoint was met with a median absorbed target volume dose of 138 Gy (IQR, [127-145]). No local recurrences were found within 1-year follow-up., Conclusion: Adjuvant (super-)selective infusion of166 Ho-MS after RFA for the treatment of HCC can be administered safely at a dose of 90 Gy to the treatment volume while reaching a dose of ≥ 120 Gy to the target volume and may be a favorable adjuvant therapy for HCC lesions 2-5 cm., Trial Registration: Clinicaltrials.gov NCT03437382 . (registered: 19-02-2018)., (© 2024. The Author(s).)- Published
- 2024
- Full Text
- View/download PDF
12. The realization of medical devices for precision surgery - development and implementation of ' stop-and-go' imaging technologies.
- Author
-
van Leeuwen FWB, Buckle T, Rietbergen DDD, and van Oosterom MN
- Subjects
- Humans, Diagnostic Imaging methods, Diagnostic Imaging instrumentation, Precision Medicine methods, Precision Medicine instrumentation, Equipment and Supplies, Surgery, Computer-Assisted instrumentation, Surgery, Computer-Assisted methods
- Abstract
Introduction: Surgery and biomedical imaging encompass a big share of the medical-device market. The ever-mounting demand for precision surgery has driven the integration of these two into the field of image-guided surgery. A key-question herein is how imaging modalities can guide the surgical decision-making process. Through performance-based design, chemists, engineers, and doctors need to build a bridge between imaging technologies and surgical challenges., Areas-Covered: This perspective article highlights the complementary nature between the technological design of an image-guidance modality and the type of procedure performed. The specific roles of the involved professionals, imaging technologies, and surgical indications are addressed., Expert-Opinion: Molecular-image-guided surgery has the potential to advance pre-, intra- and post-operative tissue characterization. To achieve this, surgeons need the access to well-designed indication-specific chemical-agents and detection modalities. Hereby, some technologies stimulate exploration ('go'), while others stimulate caution ('stop'). However, failing to adequately address the indication-specific needs rises the risk of incorrect tool employment and sub-optimal surgical performance. Therefore, besides the availability of new technologies, market growth is highly dependent on the practical nature and impact on real-life clinical care. While urology currently takes the lead in the widespread implementation of image-guidance technologies, the topic is generic and its popularity spreads rapidly within surgical oncology.
- Published
- 2024
- Full Text
- View/download PDF
13. Strong Correlation Between SUV max on PSMA PET/CT and Numeric Drop-In γ-Probe Signal for Intraoperative Identification of Prostate Cancer Lesions.
- Author
-
Berrens AC, Sorbi MA, Donswijk ML, de Barros HA, Azargoshasb S, van Oosterom MN, Rietbergen DDD, Bekers EM, van der Poel HG, van Leeuwen FWB, and van Leeuwen PJ
- Subjects
- Male, Humans, Positron Emission Tomography Computed Tomography methods, Androgen Antagonists, Prospective Studies, Neoplasm Recurrence, Local pathology, Gallium Radioisotopes, Prostatic Neoplasms diagnostic imaging, Prostatic Neoplasms surgery, Prostatic Neoplasms pathology
- Abstract
Prostate-specific membrane antigen (PSMA) PET is used to select patients with recurrent prostate cancer for metastasis-directed therapy. A surgical approach can be achieved through radioguided surgery (RGS), using a Drop-In γ-probe that traces lesions that accumulate the radioactive signal. With the aim of guiding patient selection for salvage surgery, we studied the correlation between the SUV
max of lesions on preoperative PSMA PET/CT and their intraoperative counts/s measured using the Drop-In γ-probe. Methods: A secondary analysis based on the prospective, single-arm, and single-center feasibility study was conducted (NCT03857113). Patients ( n = 29) with biochemical recurrence after previous curative-intent therapy and a maximum of 3 suggestive lesions within the pelvis on preoperative PSMA PET/CT were included. Patients treated with androgen deprivation therapy within 6 mo before surgery were excluded. All patients received an intravenous injection of99m Tc-PSMA-I&S 1 d before surgery. Radioguidance was achieved using a Drop-In γ-probe. Correlation was determined using the Spearman rank correlation coefficient (ρs). Subgroup analysis was based on the median SUVmax Results: In total, 33 lesions were visible on the PSMA PET/CT images, with a median overall SUVmax of 6.2 (interquartile range [IQR], 4.2-9.7). RGS facilitated removal of 31 lesions. The median Drop-In counts/s were 134 (IQR, 81-220) in vivo and 109 (IQR, 72-219) ex vivo. The intensity of the values correlated with SUVmax (ρs = 0.728 and 0.763, respectively; P < 0.001). Subgroup analysis based on median SUVmax in the group with an SUVmax of less than 6 showed no statistically significant correlation with the numeric signal in vivo (ρs = 0.382; P = 0.221) or the signal-to-background-ratio (ρs = 0.245; P = 0.442), whereas the group with an SUVmax of 6 or more showed respective statistically significant positive correlations (ρs = 0.774 [ P < 0.001] and ρs = 0.647 [ P = 0.007]). Conclusion: Our findings indicate that there is a direct relation between SUVmax on PSMA PET/CT and the readout recorded by the surgical Drop-In probe, thereby indicating that SUVmax can be used to select patients for PSMA RGS. For more definitive subgroup definitions for treatment recommendations, further studies are necessary to validate the present findings., (© 2024 by the Society of Nuclear Medicine and Molecular Imaging.)- Published
- 2024
- Full Text
- View/download PDF
14. Sentinel lymph node procedure in early-stage vulvar cancer: Correlation of lymphoscintigraphy with surgical outcome and groin recurrence.
- Author
-
Warmerdam DHM, van Geloven N, Beltman JJ, De Kroon CD, Rietbergen DDD, van Poelgeest MIE, and Gaarenstroom KN
- Subjects
- Humans, Female, Groin surgery, Groin pathology, Retrospective Studies, Lymphoscintigraphy methods, Sentinel Lymph Node Biopsy methods, Lymph Node Excision methods, Lymph Nodes diagnostic imaging, Lymph Nodes surgery, Lymph Nodes pathology, Treatment Outcome, Sentinel Lymph Node diagnostic imaging, Sentinel Lymph Node surgery, Sentinel Lymph Node pathology, Vulvar Neoplasms diagnostic imaging, Vulvar Neoplasms surgery, Vulvar Neoplasms pathology, Lymphadenopathy pathology, Carcinoma, Squamous Cell diagnostic imaging, Carcinoma, Squamous Cell surgery, Carcinoma, Squamous Cell pathology
- Abstract
Introduction: In early-stage vulvar squamous cell carcinoma (VSCC) a sentinel lymph node (SLN) procedure is regarded successful if at least one SLN is removed with minimal residual radioactivity. An inguinofemoral lymphadenectomy is considered if not all SLNs visualized on lymphoscintigraphy can be found, with subsequent increased morbidity. We correlated lymphoscintigraphy findings with surgical outcome and groin recurrence with focus on number of SLNs found., Methods: This study concerns a retrospective cohort of 171 women treated for early-stage VSCC who underwent a SLN procedure between 2000 and 2020. The risk of groin recurrence was compared after either a successful or complete SLN procedure, i.e. removal of all SLNs that were visualized on lymphoscintigraphy., Results: In 13 (7.6%) groins of 171 patients SLN visualization on lymphoscintigraphy failed. In 230 of the 246 (93.5%) groins in which a SLN was visualized, at least one SLN was found during surgery. In 224 of the 246 (91.1%) groins the SLN procedure was regarded either successful (n = 14) or complete (n = 210). An isolated groin recurrence was documented in 5 out of 192 (2.6%, 95%-CI; 0.34 to 4.9) SLN-negative groins after a median follow-up of 47.0 months. All recurrences were noted in the complete SLN group (5/180 groins). The difference with the successful SLN group (0/12 groins) was not significant., Conclusion: Risk of groin recurrence was 2.6% after SLN negative biopsy in early-stage VSCC. The risk appeared not increased if at least one SLN was found with minimal residual radioactivity, in case more SLNs were visualized on lymphoscintigraphy., (© 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).)
- Published
- 2023
- Full Text
- View/download PDF
15. Comparison of two hybrid sentinel node tracers: indocyanine green (ICG)- 99m Tc-nanocolloid vs. ICG- 99m Tc-nanoscan from a nuclear medicine and surgical perspective.
- Author
-
Vreeburg MTA, Azargoshasb S, van Willigen D, Molenaar T, van Oosterom MN, Buckle T, Slof LJ, Klop M, Karakullukcu B, Donswijk M, van der Poel HG, van Leeuwen FWB, Brouwer OR, and Rietbergen DDD
- Subjects
- Male, Humans, Indocyanine Green, Sentinel Lymph Node Biopsy methods, Retrospective Studies, Radiopharmaceuticals, Lymphatic Metastasis, Technetium Tc 99m Aggregated Albumin, Nuclear Medicine, Sentinel Lymph Node surgery, Melanoma diagnostic imaging, Melanoma surgery, Melanoma pathology, Penile Neoplasms pathology
- Abstract
Background: Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-
99m Tc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99m Tc-nanoscan compared to ICG-99m Tc-nanocolloid from a nuclear and surgical perspective., Methods: Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99m Tc-nanocolloid until no longer available; the second group (n = 13) received ICG-99m Tc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors., Results: The mean tracer uptake in the SNs was similar for ICG-99m Tc-nanocolloid (2.2 ± 4.3%ID) and ICG-99m Tc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99m Tc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99m Tc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99m Tc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109 -14*109 in the ICG-99m Tc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109 -42*109 in the ICG-99m Tc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported., Conclusions: Based on this retrospective analysis, we can conclude that ICG-99m Tc-nanoscan has similar capacity for SN identification as ICG-99m Tc-nanocolloid and can safely be implemented in SN procedures., (© 2023. The Author(s).)- Published
- 2023
- Full Text
- View/download PDF
16. Quantifying the Impact of Signal-to-background Ratios on Surgical Discrimination of Fluorescent Lesions.
- Author
-
Azargoshasb S, Boekestijn I, Roestenberg M, KleinJan GH, van der Hage JA, van der Poel HG, Rietbergen DDD, van Oosterom MN, and van Leeuwen FWB
- Subjects
- Humans, Coloring Agents, Surgery, Computer-Assisted
- Abstract
Purpose: Surgical fluorescence guidance has gained popularity in various settings, e.g., minimally invasive robot-assisted laparoscopic surgery. In pursuit of novel receptor-targeted tracers, the field of fluorescence-guided surgery is currently moving toward increasingly lower signal intensities. This highlights the importance of understanding the impact of low fluorescence intensities on clinical decision making. This study uses kinematics to investigate the impact of signal-to-background ratios (SBR) on surgical performance., Methods: Using a custom grid exercise containing hidden fluorescent targets, a da Vinci Xi robot with Firefly fluorescence endoscope and ProGrasp and Maryland forceps instruments, we studied how the participants' (N = 16) actions were influenced by the fluorescent SBR. To monitor the surgeon's actions, the surgical instrument tip was tracked using a custom video-based tracking framework. The digitized instrument tracks were then subjected to multi-parametric kinematic analysis, allowing for the isolation of various metrics (e.g., velocity, jerkiness, tortuosity). These were incorporated in scores for dexterity (Dx), decision making (DM), overall performance (PS) and proficiency. All were related to the SBR values., Results: Multi-parametric analysis showed that task completion time, time spent in fluorescence-imaging mode and total pathlength are metrics that are directly related to the SBR. Below SBR 1.5, these values substantially increased, and handling errors became more frequent. The difference in Dx and DM between the targets that gave SBR < 1.50 and SBR > 1.50, indicates that the latter group generally yields a 2.5-fold higher Dx value and a threefold higher DM value. As these values provide the basis for the PS score, proficiency could only be achieved at SBR > 1.55., Conclusion: By tracking the surgical instruments we were able to, for the first time, quantitatively and objectively assess how the instrument positioning is impacted by fluorescent SBR. Our findings suggest that in ideal situations a minimum SBR of 1.5 is required to discriminate fluorescent lesions, a substantially lower value than the SBR 2 often reported in literature., (© 2022. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF
17. Microspheres as a Carrier System for Therapeutic Embolization Procedures: Achievements and Advances.
- Author
-
Welling MM, Duszenko N, van Meerbeek MP, Molenaar TJM, Buckle T, van Leeuwen FWB, and Rietbergen DDD
- Abstract
The targeted delivery of anti-cancer drugs and isotopes is one of the most pursued goals in anti-cancer therapy. One of the prime examples of such an application is the intra-arterial injection of microspheres containing cytostatic drugs or radioisotopes during hepatic embolization procedures. Therapy based on the application of microspheres revolves around vascular occlusion, complemented with local therapy in the form of trans-arterial chemoembolization (TACE) or radioembolization (TARE). The broadest implementation of these embolization strategies currently lies within the treatment of untreatable hepatocellular cancer (HCC) and metastatic colorectal cancer. This review aims to describe the state-of-the-art TACE and TARE technologies investigated in the clinical setting for HCC and addresses current trials and new developments. In addition, chemical properties and advancements in microsphere carrier systems are evaluated, and possible improvements in embolization therapy based on the modification of and functionalization with therapeutical loads are explored.
- Published
- 2023
- Full Text
- View/download PDF
18. A radio- and fluorescently labelled tracer for imaging and quantification of bacterial infection on orthopaedic prostheses : a proof of principle study.
- Author
-
Welling MM, Warbroek K, Khurshid C, van Oosterom MN, Rietbergen DDD, de Boer MGJ, Nelissen RGHH, van Leeuwen FWB, Pijls BG, and Buckle T
- Abstract
Aims: Arthroplasty surgery of the knee and hip is performed in two to three million patients annually. Periprosthetic joint infections occur in 4% of these patients. Debridement, antibiotics, and implant retention (DAIR) surgery aimed at cleaning the infected prosthesis often fails, subsequently requiring invasive revision of the complete prosthetic reconstruction. Infection-specific imaging may help to guide DAIR. In this study, we evaluated a bacteria-specific hybrid tracer (
99m Tc-UBI29-41 -Cy5) and its ability to visualize the bacterial load on femoral implants using clinical-grade image guidance methods., Methods:99m Tc-UBI29-41 -Cy5 specificity for Stapylococcus aureus was assessed in vitro using fluorescence confocal imaging. Topical administration was used to highlight the location of S. aureus cultured on femoral prostheses using fluorescence imaging and freehand single photon emission CT (fhSPECT) scans. Gamma counting and fhSPECT were used to quantify the bacterial load and monitor cleaning with chlorhexidine. Microbiological culturing helped to relate the imaging findings with the number of (remaining) bacteria., Results: Bacteria could be effectively stained in vitro and on prostheses, irrespective of the presence of biofilm. Infected prostheses revealed bacterial presence on the transition zone between the head and neck, and in the screw hole. Qualitative 2D fluorescence images could be complemented with quantitative 3D fhSPECT scans. Despite thorough chlorhexidine treatments, 28% to 44% of the signal remained present in the locations of the infection that were identified using imaging, which included 500 to 2,000 viable bacteria., Conclusion: The hybrid tracer99m Tc-UBI29-41 -Cy5 allowed effective bacterial staining. Qualitative real-time fluorescence guidance could be effectively combined with nuclear imaging that enables quantitative monitoring of the effectiveness of cleaning strategies.Cite this article: Bone Joint Res 2023;12(1):72-79.- Published
- 2023
- Full Text
- View/download PDF
19. Reinducing Radioiodine-Sensitivity in Radioiodine-Refractory Thyroid Cancer Using Lenvatinib (RESET): Study Protocol for a Single-Center, Open Label Phase II Trial.
- Author
-
Dotinga M, Vriens D, van Velden FHP, Stam MK, Heemskerk JWT, Dibbets-Schneider P, Pool M, Rietbergen DDD, de Geus-Oei LF, and Kapiteijn E
- Abstract
Background : Management of patients with radioiodine (RAI)-refractory differentiated thyroid cancer (DTC) is a challenge as I-131 therapy is deemed ineffective while standard-of-care systemic therapy with tyrosine kinase inhibitor (TKI) lenvatinib is associated with frequent toxicities leading to dose reductions and withdrawal. A potential new treatment approach is to use TKIs as redifferentiation agent to restore RAI uptake to an extent that I-131 therapy is warranted. Prior studies show that short-term treatment with other TKIs restores RAI uptake in 50-60% of radioiodine-refractory DTC patients, but this concept has not been investigated for lenvatinib. Furthermore, the optimal duration of treatment with TKIs for maximal redifferentiation has not been explored. Methods and Design : A total of 12 patients with RAI-refractory DTC with an indication for lenvatinib will undergo I-124 PET/CT to quantify RAI uptake. This process is repeated after 6 and 12 weeks post-initiating lenvatinib after which the prospective dose estimate to target lesions and organs at risk will be determined. Patients will subsequently stop lenvatinib and undergo I-131 treatment if it is deemed effective and safe by predefined norms. The I-124 PET/CT measurements after 6 and 12 weeks of the first six patients are compared and the optimal timepoint will be determined for the remaining patients. In all I-131 treated patients post-therapy SPECT/CT dosimetry verification will be performed. During follow-up, clinical response will be evaluated using serum thyroglobulin levels and F-18 FDG PET/CT imaging for 6 months. It is hypothesized that at least 40% of patients will show meaningful renewed RAI uptake after short-term lenvatinib treatment. Discussion : Shorter treatment duration of lenvatinib treatment is preferred because of frequent toxicity-related dose reductions and drug withdrawals in long-term lenvatinib treatment. Short-term treatment with lenvatinib with subsequent I-131 therapy poses a potential new management approach for these patients. Since treatment duration is reduced and I-131 therapy is more tolerable for most patients, this potentially leads to less toxicity and higher quality of life. Identifying RAI-refractory DTC patients who redifferentiate after lenvatinib therapy is therefore crucial. Trial Registration : ClinicalTrials.gov, NTC04858867.
- Published
- 2022
- Full Text
- View/download PDF
20. Added Value of Respiratory Gating in Positron Emission Tomography for the Clinical Management of Lung Cancer Patients.
- Author
-
Grootjans W, Rietbergen DDD, and van Velden FHP
- Subjects
- Humans, Positron-Emission Tomography methods, Artifacts, Image Processing, Computer-Assisted, Respiration, Lung Neoplasms diagnostic imaging, Lung Neoplasms therapy, Respiratory-Gated Imaging Techniques methods
- Abstract
Positron emission tomography (PET) is an important imaging modality for personalizing clinical management of patients with lung cancer. In this regard, PET imaging is essential for adequate clinical staging and monitoring of treatment response in patients with lung cancer. The key advantage of PET over other radiological imaging modalities is its high sensitivity for the detection of pulmonary lesions, normal-sized metastatic hilar and/or mediastinal lymph nodes, and distant metastases. Furthermore, with increasing clinical evidence, the role of PET imaging for treatment selection, adaptation, early response monitoring and follow up in patients with lung cancer is being increasingly recognized. At the heart of PET imaging lies the ability to visualize and quantify numerous biological parameters that are responsible for treatment resistance. In order to ensure accurate and reproducible image quantification, harmonization of patient preparation and imaging protocols is essential. Additionally, there are several technical factors during PET scanning that have to be taken care of to safeguard image quality and quantitative accuracy. One of these factors is the occurrence of respiratory motion artifacts, which is a well-known factor that can significantly influence image quality and quantitative accuracy of PET images. If left uncorrected, respiratory motion artifacts can introduce uncertainties in diagnosis and staging, inaccuracies in definition of target volumes for radiation treatment planning, and hinder adequate monitoring of therapy response. Although many different respiratory gating techniques have been developed to correct PET images for respiratory motion artifacts, respiratory gating has traditionally not been widely adopted in clinical practice. This is due to the fact that these methods tend to be disruptive for the clinical workflow due the lengthening of image acquisition times, higher amounts of activity being administered to the patient, and the requirement to synchronize additional hardware with the scanner. Developments in respiratory gating techniques over the last years have resulted in considerable technical improvements. These newer respiratory gating techniques can operate directly on the acquired PET data without the use of additional hardware to trace respiratory motion and can be seamlessly applied into clinical routine. Furthermore, instead of only using a fraction of the acquired PET data newer methods have the ability to use all of the acquired PET data for image reconstruction, thereby improving image quality. The clinically added value of respiratory gating lies in improving image quality by reducing the amount of respiration-induced image blurring. This considerably improves the detection and characterization of small lesions, potentially improving early diagnosis and staging of patients with lung cancer. Furthermore, the incorporation of (4D) respiratory gated PET for radiotherapy purposes has shown to improve target volume definition through more accurate tracking of tumor motion. In addition, the effect of respiratory motion artifacts on widely used volumetric and uptake parameters in PET have been described. Although respiratory gating improves quantitative accuracy of PET images, the exact impact of these corrections on clinical management of patients with lung cancer often still needs to be determined., Competing Interests: Declaration of interests The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2022 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
21. Value-assessment of computer-assisted navigation strategies during percutaneous needle placement.
- Author
-
Boekestijn I, Azargoshasb S, van Oosterom MN, Slof LJ, Dibbets-Schneider P, Dankelman J, van Erkel AR, Rietbergen DDD, and van Leeuwen FWB
- Subjects
- Computers, Humans, Phantoms, Imaging, Ultrasonography, Ultrasonography, Interventional methods, Needles, Surgery, Computer-Assisted methods
- Abstract
Purpose: Navigational strategies create a scenario whereby percutaneous needle-based interventions of the liver can be guided using both pre-interventional 3D imaging datasets and dynamic interventional ultrasound (US). To score how such technologies impact the needle placement process, we performed kinematic analysis on different user groups., Methods: Using a custom biopsy phantom, three consecutive exercises were performed by both novices and experts (n = 26). The exercise came in three options: (1) US-guidance, (2) US-guidance with pre-interventional image-registration (US + Reg) and (3) US-guidance with pre-interventional image-registration and needle-navigation (US + Reg + Nav). The traveled paths of the needle were digitized in 3D. Using custom software algorithms, kinematic metrics were extracted and related to dexterity, decision making indices to obtain overall performance scores (PS)., Results: Kinematic analysis helped quantifying the visual assessment of the needle trajectories. Compared to US-guidance, novices yielded most improvements using Reg (PS
avg(US) = 0.43 vs. PSavg(US+Reg) = 0.57 vs. PSavg(US+Reg+Nav) = 0.51). Interestingly, the expert group yielded a reversed trend (PSavg(US) = 0.71 vs PSavg(US+Reg) = 0.58 vs PSavg(US+Reg+Nav) = 0.59)., Conclusion: Digitizing the movement trajectory allowed us to objectively assess the impact of needle-navigation strategies on percutaneous procedures. In particular, our findings suggest that these advanced technologies have a positive impact on the kinematics derived performance of novices., (© 2022. The Author(s).)- Published
- 2022
- Full Text
- View/download PDF
22. The current status and future prospects for molecular imaging-guided precision surgery.
- Author
-
Boekestijn I, van Oosterom MN, Dell'Oglio P, van Velden FHP, Pool M, Maurer T, Rietbergen DDD, Buckle T, and van Leeuwen FWB
- Subjects
- Humans, Molecular Imaging, Neoplasms diagnostic imaging, Neoplasms surgery, Surgery, Computer-Assisted methods
- Abstract
Molecular imaging technologies are increasingly used to diagnose, monitor, and guide treatment of i.e., cancer. In this review, the current status and future prospects of the use of molecular imaging as an instrument to help realize precision surgery is addressed with focus on the main components that form the conceptual basis of intraoperative molecular imaging. Paramount for successful interventions is the relevance and accessibility of surgical targets. In addition, selection of the correct combination of imaging agents and modalities is critical to visualize both microscopic and bulk disease sites with high affinity and specificity. In this context developments within engineering/imaging physics continue to drive the growth of image-guided surgery. Particularly important herein is enhancement of sensitivity through improved contrast and spatial resolution, features that are critical if sites of cancer involvement are not to be overlooked during surgery. By facilitating the connection between surgical planning and surgical execution, digital surgery technologies such as computer-aided visualization nicely complement these technologies. The complexity of image guidance, combined with the plurality of technologies that are becoming available, also drives the need for evaluation mechanisms that can objectively score the impact that technologies exert on the performance of healthcare professionals and outcome improvement for patients., (© 2022. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
23. Evaluation of the Hybrid Tracer Indocyanine Green- 99m Tc-Nanocolloid for Sentinel Node Biopsy in Bladder Cancer-A Prospective Pilot Study.
- Author
-
Rietbergen DDD, van Gennep EJ, KleinJan GH, Donswijk M, Valdés Olmos RA, van Rhijn BW, van der Poel HG, and van Leeuwen FWB
- Subjects
- Colloids, Humans, Indocyanine Green, Middle Aged, Nanostructures, Pilot Projects, Prospective Studies, Sentinel Lymph Node Biopsy methods, Technetium, Technetium Tc 99m Aggregated Albumin, Sentinel Lymph Node diagnostic imaging, Urinary Bladder Neoplasms diagnostic imaging
- Abstract
Rationale: In muscle-invasive bladder cancer (MIBC), lymph node invasion has proven to be an independent predictor of disease recurrence and cancer-specific survival. We evaluated the feasibility of targeting the sentinel node (SN) for biopsy in MIBC patients using the hybrid tracer indocyanine green (ICG)- 99m Tc-nanocolloid for simultaneous radioguidance and fluorescence guidance., Methods: Twenty histologically confirmed cN0M0 MIBC patients (mean age, 63.3 years; range, 30-82 years), scheduled for radical cystectomy with SN biopsy and extended pelvic lymph node dissection (ePLND), were prospectively included. Twelve patients were operated on following neoadjuvant chemotherapy. The patients received lymphoscintigraphy as well as SPECT/CT after 4 transurethral injections of ICG- 99m Tc-nanocolloid (mean, 208 MBq; range, 172-229 MBq) around the tumor/scar in the detrusor muscle of the bladder on the day before radical cystectomy. Sentinel node resection was performed under radioguidance and fluorescence guidance., Results: Nineteen patients could be analyzed. On preoperative imaging, SNs could be identified in 10 patients (53%; mean, 1.6 SN/patient), which revealed drainage pathways outside the ePLND in 20% of the patients. Interesting to note is that 2 patients (10%) with preoperative nonvisualization displayed fluorescent and radioactive SNs during surgery. Location of the primary tumor near the left lateral side of the bladder seemed to be a factor for nonvisualization. Nodal harvesting with ePLND varied among patients (mean, 23.3). Histopathology confirmed tumor-positive nodes in 4 (21%) of all patients. In the 2 patients where an SN could be identified, the ePLND specimens were tumor-negative. All patients with tumor-positive nodes had advanced disease (stage III)., Conclusion: Sentinel node biopsy in bladder cancer using the hybrid tracer ICG- 99m Tc-nanocolloid is feasible, and preoperative imaging is predictive for the ability to perform SN biopsy in 83% of the patients who displayed an SN. In patients with a successful preoperative SN mapping using lymphoscintigraphy and SPECT/CT, the intraoperative SN guidance and detection were effective, even outside the ePLND area. As such, this study underscores the critical role that preoperative imaging plays in challenging image-guided surgery applications., Competing Interests: Conflicts of interest and sources of funding: This work was partially supported by an NWO-STW-VIDI grant (grant STW BGT11272). There are no potential conflicts of interest or payments received from a third party., (Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc.)
- Published
- 2022
- Full Text
- View/download PDF
24. Study Protocol: Adjuvant Holmium-166 Radioembolization After Radiofrequency Ablation in Early-Stage Hepatocellular Carcinoma Patients-A Dose-Finding Study (HORA EST HCC Trial).
- Author
-
Hendriks P, Rietbergen DDD, van Erkel AR, Coenraad MJ, Arntz MJ, Bennink RJ, Braat AE, Crobach ASLP, van Delden OM, van der Hulle T, Klümpen HJ, van der Meer RW, Nijsen JFW, van Rijswijk CSP, Roosen J, Ruijter BN, Smit F, Stam MK, Takkenberg RB, Tushuizen ME, van Velden FHP, de Geus-Oei LF, and Burgmans MC
- Subjects
- Holmium, Humans, Prospective Studies, Radioisotopes, Retrospective Studies, Tissue Distribution, Treatment Outcome, Carcinoma, Hepatocellular diagnostic imaging, Carcinoma, Hepatocellular surgery, Catheter Ablation, Embolization, Therapeutic methods, Liver Neoplasms diagnostic imaging, Liver Neoplasms drug therapy, Liver Neoplasms surgery, Radiofrequency Ablation
- Abstract
Purpose: To investigate the biodistribution of holmium-166 microspheres (
166 Ho-MS) when administered after radiofrequency ablation (RFA) of early-stage hepatocellular carcinoma (HCC). The aim is to establish a perfused liver administration dose that results in a tumoricidal dose of holmium-166 on the hyperaemic zone around the ablation necrosis (i.e. target volume)., Materials and Methods: This is a multicentre, prospective, dose-escalation study in HCC patients with a solitary lesion 2-5 cm, or a maximum of 3 lesions of ≤ 3 cm each. The day after RFA patients undergo angiography and cone-beam CT (CBCT) with (super)selective infusion of technetium-99 m labelled microalbumin aggregates (99m Tc-MAA). The perfused liver volume is segmented from the CBCT and166 Ho-MS is administered to this treatment volume 5-10 days later. The dose of holmium-166 is escalated in a maximum of 3 patient cohorts (60 Gy, 90 Gy and 120 Gy) until the endpoint is reached. SPECT/CT is used to determine the biodistribution of holmium-166. The endpoint is met when a dose of ≥ 120 Gy has been reached on the target volume in 9/10 patients of a cohort. Secondary endpoints include toxicity, local recurrence, disease-free and overall survival., Discussion: This study aims to find the optimal administration dose of adjuvant radioembolization with166 Ho-MS after RFA. Ultimately, the goal is to bring the efficacy of thermal ablation up to par with surgical resection for early-stage HCC patients., Trial Registration: Clinicaltrials.gov identifier: NCT03437382., (© 2022. The Author(s).)- Published
- 2022
- Full Text
- View/download PDF
25. The Value of 18 F-FDG-PET-CT Imaging in Treatment Evaluation of Colorectal Liver Metastases: A Systematic Review.
- Author
-
Bijlstra OD, Boreel MME, van Mossel S, Burgmans MC, Kapiteijn EHW, Oprea-Lager DE, Rietbergen DDD, van Velden FHP, Vahrmeijer AL, Swijnenburg RJ, Mieog JSD, and de Geus-Oei LF
- Abstract
(1) Background: Up to 50% of patients with colorectal cancer either have synchronous colorectal liver metastases (CRLM) or develop CRLM over the course of their disease. Surgery and thermal ablation are the most common local treatment options of choice. Despite development and improvement in local treatment options, (local) recurrence remains a significant clinical problem. Many different imaging modalities can be used in the follow-up after treatment of CRLM, lacking evidence-based international consensus on the modality of choice. In this systematic review, we evaluated
18 F-FDG-PET-CT performance after surgical resection, thermal ablation, radioembolization, and neoadjuvant and palliative chemotherapy based on current published literature. (2) Methods: A systematic literature search was performed on the PubMed database. (3) Results: A total of 31 original articles were included in the analysis. Only one suitable study was found describing the role of18 F-FDG-PET-CT after surgery, which makes it hard to draw a firm conclusion.18 F-FDG-PET-CT showed to be of additional value in the follow-up after thermal ablation, palliative chemotherapy, and radioembolization.18 F-FDG-PET-CT was found to be a poor to moderate predictor of pathologic response after neoadjuvant chemotherapy. (4) Conclusions:18 F-FDG-PET-CT is superior to conventional morphological imaging modalities in the early detection of residual disease after thermal ablation and in the treatment evaluation and prediction of prognosis during palliative chemotherapy and after radioembolization, and18 F-FDG-PET-CT could be considered in selected cases after neoadjuvant chemotherapy and surgical resection.- Published
- 2022
- Full Text
- View/download PDF
26. Inter-observer agreement of vertebral fracture assessment with dual-energy x-ray absorptiometry equipment.
- Author
-
Mostert JM, Romeijn SR, Dibbets-Schneider P, Rietbergen DDD, Pereira Arias-Bouda LM, Götz C, DiFranco MD, Dimai HP, and Grootjans W
- Subjects
- Absorptiometry, Photon, Humans, Lumbar Vertebrae injuries, Observer Variation, Retrospective Studies, Thoracic Vertebrae, Spinal Fractures diagnostic imaging
- Abstract
Purpose: To investigate the time and effort needed to perform vertebral morphometry, as well as inter-observer agreement for identification of vertebral fractures on vertebral fracture assessment (VFA) images., Methods: Ninety-six images were retrospectively selected, and three radiographers independently performed semi-automatic 6-point morphometry. Fractures were identified and graded using the Genant classification. Time needed to annotate each image was recorded, and reader fatigue was assessed using a modified Simulator Sickness Questionnaire (SSQ). Inter-observer agreement was assessed per-patient and per-vertebra for detecting fractures of all grades (grades 1-3) and for grade 2 and 3 fractures using the kappa statistic. Variability in measured vertebral height was evaluated using the intraclass correlation coefficient (ICC)., Results: Per-patient agreement was 0.59 for grades 1-3 fracture detection, and 0.65 for grades 2-3 only. Agreement for per-vertebra fracture classification was 0.92. Vertebral height measurements had an ICC of 0.96. Time needed to annotate VFA images ranged between 91 and 540 s, with a mean annotation time of 259 s. Mean SSQ scores were significantly lower at the start of a reading session (1.29; 95% CI: 0.81-1.77) compared to the end of a session (3.25; 95% CI: 2.60-3.90; p < 0.001)., Conclusion: Agreement for detection of patients with vertebral fractures was only moderate, and vertebral morphometry requires substantial time investment. This indicates that there is a potential benefit for automating VFA, both in improving inter-observer agreement and in decreasing reading time and burden on readers., (© 2021. International Osteoporosis Foundation and National Osteoporosis Foundation.)
- Published
- 2021
- Full Text
- View/download PDF
27. Liver Decompensation as Late Complication in HCC Patients with Long-Term Response following Selective Internal Radiation Therapy.
- Author
-
van Doorn DJ, Hendriks P, Burgmans MC, Rietbergen DDD, Coenraad MJ, van Delden OM, Bennink RJ, Labeur TA, Klümpen HJ, Eskens FALM, Moelker A, Vegt E, Sprengers D, Mostafavi N, Ijzermans J, and Takkenberg RB
- Abstract
Selective internal radiation therapy (SIRT) is used as a treatment for hepatocellular carcinoma (HCC). The aim of this study was to assess long-term liver-related complications of SIRT in patients who had not developed radioembolization-induced liver disease (REILD). The primary outcome was the percentage of patients without REILD that developed Child-Pugh (CP) ≥ B7 liver decompensation after SIRT. The secondary outcomes were overall survival (OS) and tumor response. These data were compared with a matched cohort of patients treated with sorafenib. Eighty-five patients were included, of whom 16 developed REILD. Of the remaining 69 patients, 38 developed liver decompensation CP ≥ B7. The median OS was 18 months. In patients without REILD, the median OS in patients with CP ≥ B7 was significantly shorter compared to those without CP ≥ B7; 16 vs. 31 months. In the case-matched analysis, the median OS was significantly longer in SIRT-treated patients; 16 vs. 8 months in sorafenib. Liver decompensation CP ≥ B7 occurred significantly more in SIRT when compared to sorafenib; 62% vs. 27%. The ALBI score was an independent predictor of liver decompensation (OR 0.07) and OS (HR 2.83). After SIRT, liver decompensation CP ≥ B7 often developed as a late complication in HCC patients and was associated with a shorter OS. The ALBI score was predictive of CP ≥ B7 liver decompensation and the OS, and this may be a valuable marker for patient selection for SIRT.
- Published
- 2021
- Full Text
- View/download PDF
28. Interventional nuclear medicine: "click" chemistry as an in vivo targeting strategy for imaging microspheres and bacteria.
- Author
-
Welling MM, Duszenko N, van Willigen DM, Hensbergen AW, Buckle T, Rietbergen DDD, Roestenberg M, and van Leeuwen FWB
- Subjects
- Animals, Mice, Microspheres, Staphylococcus aureus, Tissue Distribution, Click Chemistry, Nuclear Medicine
- Abstract
Aim: Pre-targeting is a proven strategy for in vivo delivery of a diagnostic or therapeutic payload. The pre-targeting concept can be realized through various conjugation strategies, one of which is based on copper-free "click" chemistry. Copper-free click reactions have shown in vivo potential for imaging and radionuclide therapy, but this conjugation strategy has not yet been explored in combination with microspheres or unicellular organisms. This study aims to evaluate the in vivo efficacy of strain-promoted azide-alkyne cycloaddition (SPAAC) reactions to achieve imaging and targeting of azide-functionalized macro-aggregated albumin (MAA) microspheres and Staphylococcus aureus bacteria., Methods: MAA microspheres (diameter 10-90 μm) were functionalized with a biorthogonal Cy5 fluorophore, bearing an azide functionality (N3), to generate MAA-Cy5-N3. S. aureus (diameter ∼1 μm) were functionalized with 99mTc-UBI29-41-Cy5-N3, generating S. aureus-99mTc-UBI29-41-Cy5-N3. In situ and in vitro click conjugation on the -N3 moieties was studied for 20 h using a radioactivity-based assay and fluorescence microscopy. For in vivo validation, both primary entities, radiolabeled with 99mTc, were deposited into the microvasculature of the liver via intrasplenic injections. Secondary targeting was realized following the intravenous administration of indium-111-radiolabeled diethylenetriaminepentaacetic acid-dibenzocyclooctyne (111In-DTPA-DBCO). To assess click reaction efficiency in vivo, 99mTc and 111In-biodistributions were measured (SPECT and %ID g-1). Use of 111In-DTPA-DBCO in mice without MAA deposits or mice infected with non-functionalized S. aureus served as controls. Ex vivo confocal fluorescence imaging was carried out in excised tissues to confirm the presence of functionalized MAA and bacteria., Results: In vitro data confirmed effective click reactions on both the MAA particles and the bacterial membrane. SPECT imaging and biodistribution studies revealed significantly (p < 0.05) increased accumulation of 111In-DTPA-DBCO at the sites where MAA-Cy5-N3 (7.5 ± 1.5%ID g-1vs. 3.5 ± 0.5%ID g-1 in control mice) and S. aureus-99mTc-UBI29-41-Cy5-N3 (9.3 ± 1.3%ID g-1vs. 6.0 ± 0.5%ID g-1 in control mice) resided. Ex vivo fluorescence imaging confirmed the presence of either functionalized MAA or S. aureus in excised spleens and livers of mice., Conclusion: Copper-free click chemistry between a DBCO moiety and Cy5-N3-functionalized microspheres or bacterial entities in the liver can be used to realize in vivo imaging and targeting.
- Published
- 2021
- Full Text
- View/download PDF
29. Near-infrared fluorescence imaging compared to standard sentinel lymph node detection with blue dye in patients with vulvar cancer - a randomized controlled trial.
- Author
-
Deken MM, van Doorn HC, Verver D, Boogerd LSF, de Valk KS, Rietbergen DDD, van Poelgeest MIE, de Kroon CD, Beltman JJ, van Leeuwen FWB, Putter H, Braak JPBM, de Geus-Oei LF, van de Velde CJH, Burggraaf J, Vahrmeijer AL, and Gaarenstroom KN
- Subjects
- Adult, Aged, Aged, 80 and over, Carcinoma, Squamous Cell secondary, Carcinoma, Squamous Cell surgery, Coloring Agents administration & dosage, Female, Humans, Lymph Node Excision, Lymphatic Metastasis therapy, Middle Aged, Netherlands, Operative Time, Optical Imaging methods, Radiopharmaceuticals administration & dosage, Sentinel Lymph Node pathology, Sentinel Lymph Node surgery, Sentinel Lymph Node Biopsy methods, Time Factors, Vulvar Neoplasms pathology, Vulvectomy, Carcinoma, Squamous Cell diagnosis, Intraoperative Care methods, Lymphatic Metastasis diagnosis, Sentinel Lymph Node diagnostic imaging, Vulvar Neoplasms surgery
- Abstract
Objective: The aim of this study was to assess the superiority of ICG-
99m Tc-nanocolloid for the intraoperative visual detection of sentinel lymph nodes (SLNs) in vulvar squamous cell carcinoma (VSCC) patients compared to standard SLN detection using99m Tc-nanocolloid with blue dye., Methods: In this multicenter, randomized controlled trial, VSCC patients underwent either the standard SLN procedure or with the hybrid tracer ICG-99m Tc-nanocolloid. The primary endpoint was the percentage of fluorescent SLNs compared to blue SLNs. Secondary endpoints were successful SLN procedures, surgical outcomes and postoperative complications., Results: Forty-eight patients were randomized to the standard (n = 24) or fluorescence imaging group (n = 24) using ICG-99m Tc-nanocolloid. The percentage of blue SLNs was 65.3% compared to 92.5% fluorescent SLNs (p < 0.001). A successful SLN procedure was obtained in 92.1% of the groins in the standard group and 97.2% of the groins in the fluorescence imaging group (p = 0.33). Groups did not differ in surgical outcome, although more short-term postoperative complications were documented in the standard group (p = 0.041)., Conclusions: Intraoperative visual detection of SLNs in patients with VSCC using ICG-99m Tc-nanocolloid was superior compared to99m Tc-nanocolloid and blue dye. The rate of successful SLN procedures between both groups was not significantly different. Fluorescence imaging has potential to be used routinely in the SLN procedure in VSCC patients to facilitate the search by direct visualization., Clinical Trial Registration: Netherlands Trial Register (Trial ID NL7443)., (Copyright © 2020 The Author(s). Published by Elsevier Inc. All rights reserved.)- Published
- 2020
- Full Text
- View/download PDF
30. Sentinel Node Imaging and Radioguided Surgery in the Era of SPECT/CT and PET/CT: Toward New Interventional Nuclear Medicine Strategies.
- Author
-
Valdés Olmos RA, Rietbergen DDD, Rubello D, Pereira Arias-Bouda LM, Collarino A, Colletti PM, Vidal-Sicart S, and van Leeuwen FWB
- Subjects
- Humans, Sentinel Lymph Node pathology, Image-Guided Biopsy methods, Nuclear Medicine, Positron Emission Tomography Computed Tomography, Sentinel Lymph Node diagnostic imaging, Sentinel Lymph Node surgery, Single Photon Emission Computed Tomography Computed Tomography
- Abstract
We review recent technological advances and new clinical indications for sentinel node (SN) and radioguided surgery in order to delineate future tendencies of interventional nuclear medicine in this field. A literature research was performed in PubMed to select relevant articles to be used as key references for analysis of the current approaches and tendencies in SN and radioguided surgery, as well as the evolving contribution of nuclear medicine intervention techniques to the various clinical applications. For classic indications such as melanoma and breast cancer, the incorporation of the SN approach based on the combined use of existing and new preoperative and intraoperative technologies in high-risk patient categories is becoming an emerging area of clinical indication. For SN biopsy staging in other malignancies with more complex lymphatic drainage, the incorporation of sophisticated tools is most helpful. The consecutive use of PET/CT and the SN procedure is increasing as a potential combined approach for the management of specific areas such as the axilla and the pelvis in patients at high risk of regional dissemination. Also, for the management of locoregional metastasis and oligometastatic disease, interventional nuclear medicine techniques are becoming valuable alternatives. The extended experience with SN biopsy is leading to technological advances facilitating the incorporation of this procedure to stage other malignancies with complex lymphatic drainage. New nuclear medicine-based approaches, incorporating SPECT/CT and PET/CT to guide resection of SNs and occult metastases, have recently been gaining ground.
- Published
- 2020
- Full Text
- View/download PDF
31. Head-to-head comparison of the hybrid tracer indocyanine green-99mTc-nanocolloid with 99mTc-Senti-Scint using sentinel node lymphoscintigraphy and single-photon emission computed tomography combined with computer tomography in melanoma.
- Author
-
Rietbergen DDD, Meershoek P, KleinJan GH, Donswijk M, Valdés Olmos RA, van Leeuwen FWB, Klop MWMC, and van der Hage JA
- Subjects
- Adult, Aged, Female, Humans, Male, Melanoma pathology, Middle Aged, Radioactive Tracers, Sentinel Lymph Node Biopsy, Indocyanine Green chemistry, Lymphoscintigraphy methods, Melanoma diagnostic imaging, Sentinel Lymph Node diagnostic imaging, Single Photon Emission Computed Tomography Computed Tomography methods, Technetium Tc 99m Aggregated Albumin chemistry
- Abstract
Objective: The hybrid tracer indocyanine green (ICG)-Tc-nanocolloid has been introduced for sentinel node imaging. However, until now, a comparison of this tracer with other radiocolloids with a larger particle size has not been effectuated. Based on a head-to-head evaluation in patients with melanoma, we have compared ICG-Tc-nanocolloid (particle size 5-80 nm) with Tc-Senti-Scint (particle size 100-600 nm) to establish differences in drainage pattern and sentinel node localization using lymphoscintigraphy and single-photon emission computed tomography combined with computer tomography (SPECT-CT) in melanoma patients scheduled for sentinel node biopsy., Methods: Twenty-five patients (mean age: 56.9 years, range: 25-79 years) with a melanoma scheduled for SLN biopsy prior to (re)excision of the primary lesion (scar) were prospectively included following a two-day procedure. The first day, after Tc-Senti-Scint injection in four intradermal depots around the primary lesion or scar, early/delayed lymphoscintigraphy and SPECT-CT images were acquired. The injection sites were marked. The second day, after assessing lymph node radioactivity using planar scintigraphy, ICG-Tc-nanocolloid was injected at the previously marked skin points and imaging was performed. The paired planar and SPECT-CT images of both tracers were evaluated with respect to drainage patterns, SLN visualization and non-SLN appearing., Results: Twenty-four out of 25 patients were evaluable. SLN visualization on a patient basis was 100% for ICG-Tc-nanocolloid and 96% for Tc-Senti-Scint, whereas uptake in non-SLNs was found in, respectively, 71% (17/24) and 61% (14/23). Concordance in drainage to 45 lymph node basins was 91%. Discordant drainage was found for two melanomas in the head-and-neck and one in the clavicular area. Unique lymph node basins were seen in 44/45 (98%) for ICG-Tc-nanocolloid and 42/45 (93%) for Tc-Senti-Scint. Concerning identified SLNs, the number was similar for both tracers (n = 58); however, more non-SLNs (65 vs 50) were visualized with ICG-Tc-nanocolloid than with Tc-Senti-Scint., Conclusion: A slightly higher SLN visualization accompanied by a tendency to depict more non-SLNs was found for ICG-Tc-nanocolloid. Excepting the head and neck area, an overall high concordance in drainage was found for both radiotracers. With an additional value for the hybrid tracer due to the combination of preoperative imaging and the additional visual signal in the operation room, added by the fluorescent component of the hybrid tracer, there was a preference for ICG-Tc-nanocolloid.
- Published
- 2020
- Full Text
- View/download PDF
32. Does a Widely Adopted Approach Need Reconsideration: Embolization of Parasitized Extrahepatic Tumor Feeders in Patients Undergoing Transarterial Liver-Directed Therapy?
- Author
-
Burgmans MC, Hendriks P, and Rietbergen DDD
- Subjects
- Humans, Liver diagnostic imaging, Chemoembolization, Therapeutic, Embolization, Therapeutic, Neoplasms
- Published
- 2020
- Full Text
- View/download PDF
33. Recent advances in nuclear and hybrid detection modalities for image-guided surgery.
- Author
-
Van Oosterom MN, Rietbergen DDD, Welling MM, Van Der Poel HG, Maurer T, and Van Leeuwen FWB
- Subjects
- Humans, Positron-Emission Tomography, Radioisotopes chemistry, Tomography, Emission-Computed, Single-Photon, Nuclear Medicine, Surgery, Computer-Assisted methods
- Abstract
Introduction : Radioguided surgery is an ever-evolving part of nuclear medicine. In fact, this nuclear medicine sub-discipline actively bridges non-invasive molecular imaging with surgical care. Next to relying on the availability of radio- and bimodal-tracers, the success of radioguided surgery is for a large part dependent on the imaging modalities and imaging concepts available for the surgical setting. With this review, we have aimed to provide a comprehensive update of the most recent advances in the field. Areas covered : We have made an attempt to cover all aspects of radioguided surgery: 1) the use of radioisotopes that emit γ, β
+ , and/or β- radiation, 2) hardware developments ranging from probes to 2D cameras and even the use of advanced 3D interventional imaging solutions, and 3) multiplexing solutions such as dual-isotope detection or combined radionuclear and optical detection. Expert opinion : Technical refinements in the field of radioguided surgery should continue to focus on supporting its implementation in the increasingly complex minimally invasive surgical setting, e.g. by accommodating robot-assisted laparoscopic surgery. In addition, hybrid concepts that integrate the use of radioisotopes with other image-guided surgery modalities such as fluorescence or ultrasound are likely to expand in the future.- Published
- 2019
- Full Text
- View/download PDF
34. Freehand-SPECT with 99m Tc-HDP as tool to guide percutaneous biopsy of skeletal lesions detected on bone scintigraphy.
- Author
-
Rietbergen DDD, Meershoek P, van Oosterom MN, Roestenberg M, van Erkel AR, Smit F, van der Hage JA, Valdés Olmos RA, and van Leeuwen FWB
- Subjects
- Bone Diseases pathology, Bone Neoplasms diagnostic imaging, Bone Neoplasms secondary, Double-Blind Method, Equipment Design, Humans, Image-Guided Biopsy instrumentation, Organ Specificity, Phantoms, Imaging, Pilot Projects, Radiopharmaceuticals pharmacokinetics, Software, Technetium Tc 99m Medronate pharmacokinetics, Tomography, Emission-Computed, Single-Photon instrumentation, Whole Body Imaging, Biopsy, Needle methods, Bone Diseases diagnostic imaging, Gamma Cameras, Image-Guided Biopsy methods, Technetium Tc 99m Medronate analogs & derivatives, Tomography, Emission-Computed, Single-Photon methods
- Abstract
Purpose: To assess the feasibility of using freehand Single Photon Emission Computed Tomography (freehandSPECT) for the identification of technetium-99m-hydroxydiphosphonate (
99m Tc-HDP) positive bone lesions and to evaluate the possibility of using these imaging data-sets for augmented- and virtual-reality based navigation approaches., Material and Methods: In 20 consecutive patients referred for scintigraphy with99m Tc-HDP, 21 three-dimensional freehandSPECT-images were generated using a handheld gamma camera. Concordance of the two different data sets was ranked. Furthermore, feasibility of segmenting the hotspot of tracer accumulation for navigation purposes was assessed., Results: In 86% of the cases freehandSPECT images showed good concordance with the corresponding part of the scintigraphic images. In lesions with a signal to background ratio (SBR) >1.36, freehandSPECT provided an automatically segmented reference point for navigation purposes. In 14% of the cases (average SBR 1.82, range 1.0-3.4) freehandSPECT images showed intermediate concordance due to difficult anatomical area or negative bone scintigraphy and could not be used as navigation targets., Conclusion: In this pilot study, in 86% of the cases freehandSPECT demonstrated good concordance with traditional scintigraphy. A lesion with a SBR of 1.36 or more was suitable for navigation. These high-quality freehandSPECT images supported the future exploration navigation strategies, e.g. guided needle biopsies., (Copyright © 2019 Sociedad Española de Medicina Nuclear e Imagen Molecular. Publicado por Elsevier España, S.L.U. All rights reserved.)- Published
- 2019
- Full Text
- View/download PDF
35. In vivo stability of supramolecular host-guest complexes monitored by dual-isotope multiplexing in a pre-targeting model of experimental liver radioembolization.
- Author
-
Welling MM, Spa SJ, van Willigen DM, Rietbergen DDD, Roestenberg M, Buckle T, and van Leeuwen FWB
- Subjects
- Albumins, Animals, Indium Radioisotopes, Maleic Anhydrides, Mice, Polymers, Radiopharmaceuticals, Technetium, beta-Cyclodextrins, Embolization, Therapeutic, Liver
- Abstract
Introduction: Cyclodextrin (CD)-based supramolecular interactions have been proposed as nanocarriers for drug delivery. We previously explored the use of these supramolecular interactions to perform targeted hepatic radioembolization. In a two-step procedure the appropriate location of the diagnostic pre-targeting vector can first be confirmed, after which the therapeutic vector will be targeted through multivalent host-guest interactions. Such a procedure would prevent therapeutic errors that come from a mismatch between diagnostic and therapeutic procedures. In the current study we explored the use of dual-isotope imaging to assess the in vivo stability of the formed complex and individual components., Methods: Dual-isotope imaging of the host and guest vectors was performed after labeling of the pre-targeted guest vector, being adamantane (Ad) functionalized macro-aggregated albumin (MAA) particles, with technetium-99 m (
99m Tc-MAA-Ad). The host vector, Cy50.5 CD9 PIBMA39 , was labeled with indium-111 (111 In-Cy50.5 CD9 PIBMA39 ). The in situ stability of both the individual vectors and the resulting [MAA-Ad-111 In-Cy50.5 CD9 PIBMA39 ] complexes was studied over 44 h at 37 °C in a serum protein-containing buffer. In vivo, the host vector111 In-Cy50.5 CD9 PIBMA39 was administered two hours after local deposition of99m Tc-MAA-Ad in mice. Dual-isotope SPECT imaging and quantitative biodistribution studies were performed between 2 and 44 h post intravenous host vector administration., Results: The individual vectors portrayed <5% dissociation of the radioisotope over the course of 20 h. Dissociation of [MAA-Ad-111 In-Cy50.5 CD9 PIBMA39 ] complexes remained within a 10-20% range after incubation in serum. In vivo dual-isotope SPECT imaging of host-guest interactions revealed co-localization of the tracer components. Quantitative assessment of the biodistribution revealed that the hepatic accumulation of the host vector nearly doubled between 2 h and 44 h post-injection (from 14.9 ± 6.1%ID/g to 26.2 ± 2.1%ID/g)., Conclusions: Assessment of intra-hepatic host-guest complexation was successfully achieved using dual isotope multiplexing, underlining the complex stability that was found in situ (up to 44 h in serum). Overall, the results obtained in this study highlight the potential of supramolecular chemistry as a versatile platform that could advance the field of nanomedicine., (Copyright © 2018 Elsevier B.V. All rights reserved.)- Published
- 2019
- Full Text
- View/download PDF
36. A Supramolecular Approach for Liver Radioembolization.
- Author
-
Spa SJ, Welling MM, van Oosterom MN, Rietbergen DDD, Burgmans MC, Verboom W, Huskens J, Buckle T, and van Leeuwen FWB
- Subjects
- Albumins metabolism, Animals, Carcinoma, Hepatocellular drug therapy, Cyclodextrins pharmacology, Embolization, Therapeutic methods, Humans, Liver drug effects, Liver Neoplasms drug therapy, Mice, Microspheres, Radioisotopes administration & dosage, Radionuclide Imaging methods, Radiopharmaceuticals administration & dosage, Tomography, Emission-Computed, Single-Photon methods, Carcinoma, Hepatocellular therapy, Liver radiation effects, Liver Neoplasms therapy
- Abstract
Hepatic radioembolization therapies can suffer from discrepancies between diagnostic planning (scout-scan) and the therapeutic delivery itself, resulting in unwanted side-effects such as pulmonary shunting. We reasoned that a nanotechnology-based pre-targeting strategy could help overcome this shortcoming by directly linking pre-interventional diagnostics to the local delivery of therapy. Methods: The host-guest interaction between adamantane and cyclodextrin was employed in an in vivo pre-targeting set-up. Adamantane (guest)-functionalized macro albumin aggregates (MAA-Ad; d = 18 μm) and (radiolabeled) Cy5 and β-cyclodextrin (host)-containing PIBMA polymers (
99m Tc-Cy50.5 CD10 PIBMA39 ; MW ~ 18.8 kDa) functioned as the reactive pair. Following liver or lung embolization with (99m Tc)-MAA-Ad or (99m Tc)-MAA (control), the utility of the pre-targeting concept was evaluated after intravenous administration of99m Tc-Cy50.5 CD10 PIBMA39 . Results: Interactions between MAA-Ad and Cy50.5 CD10 PIBMA39 could be monitored in solution using confocal microscopy and were quantified by radioisotope-based binding experiments. In vivo the accumulation of the MAA-Ad particles in the liver or lungs yielded an approximate ten-fold increase in accumulation of99m Tc-Cy50.5 CD10 PIBMA39 in these organs (16.2 %ID/g and 10.5 %ID/g, respectively) compared to the control. Pre-targeting with MAA alone was shown to be only half as efficient. Uniquely, for the first time, this data demonstrates that the formation of supramolecular interactions between cyclodextrin and adamantane can be used to drive complex formation in the chemically challenging in vivo environment. Conclusion: The in vivo distribution pattern of the cyclodextrin host could be guided by the pre-administration of the adamantane guest, thereby creating a direct link between the scout-scan (MAA-Ad) and delivery of therapy., Competing Interests: Competing Interests: The authors have declared that no competing interest exists.- Published
- 2018
- Full Text
- View/download PDF